24 Hours Room Temperature Curing Epoxy Resin For Coil Frame Work Medium Viscosity

Brand Name:JT-RESIN
Certification:SGS,CE,UL
Model Number:JT8218A/B
Minimum Order Quantity:25KG
Delivery Time:3 days
Payment Terms:L/C, T/T, Western Union, MoneyGram
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou Hebei China
Address: Room 606, Donghong International Plaza, No. 113 Chebei Road, Tianhe District, Guangzhou, China
Supplier`s last login times: within 36 hours
Product Details Company Profile
Product Details

Epoxy electrical insulation OF ROOM TEMPERATURE CURING FOR COIL FRAME WORK

PRODUCT MSDS:


1. IDENTIFICATION

Commodity name: JT 8054A Modified epoxy resin

Company Name: HUBEI JIANGTE INSULATION COMPOSITE CO., LTD.

Add: Room219 Zhanghua Road(N), EDA Qianjiang City, Hubei Province, China

Tel:+86-728-6201068

Fax:+86-728-6202066

Zip code:433132


2. HAZARDS IDENTIFICATION

Irritating to eyes and skin.

May cause sensitization by skin contact.

Toxic to aquatic organisms, may cause long-term adverse effects in the aquatic environment.


3. COMPOSITON INFORMATION ON INGREDIENT

Chemical NameCAS No.Content(%)
4,4'-(1-methylethylidene)bisphenol polymer with (chloromethyl)oxirane25068-38-6>90.0 - <100.0
Poly(propylene glycol)25322-69-4>0.0 - <10.0


Product TDS:


Epoxy Electrical Insulation System

JT 8218A Epoxy Resin 100 pbw

JT 8218B Epoxy Hardener 20-25 pbw

Used for:low voltage CT(and zero-sequence instrument transformers)

electronic components such as: ignition, regulator, electronic transformers, network transformers, pump motor, ignition coil, transformer, negative ion generator, AC capacitor, (vertical, horizontal, cartridge, film capacitor), power module, LED module, insulating pouring lamps etc. Appropriate operation time, easy to produce the work. Can withstand high and low temperature curve, with excellent electrical properties and physical properties.


Applications

For common vacuum casting processing, the typical mould temperature is 70℃–80℃, demoulding time( different as per temperature and volume) is about 5-8h. Keeping 10h at 130℃ after curing. Demoulding time and after-curing cycle need to be determined as per specific product design and technology. Please kindly contact our techanicians for more information


Processing methods

Room Temperature curing

Good flame reardant

Low viscosity

Good impregnation

Long pot life

Good adhesion to the coil skeleton

Properties


Product data(Guideline values) *

JT 8218 A modified Epoxy resin

TYPICAL VALUES*

Viscosity @ 25, mPa.s [ISO 2555] .....................................................................2,000-6,000

Density @ 25℃ , g/cm3 [ISO 1675] ........................................................................ 1.50-1.70

Storage life @ 25℃ (sealed container), month …………………………………………….………………..12

Remark:In order to prevent the absorption of moisture,please keep epoxy resin in sealed container and storage under normal temperature (about 20 to 25℃).


JT 8218 B Modified liquid hardener

TYPICAL VALUES*

Viscosity @ 25℃, mPa.s [ISO 2555] .............................................................................30-300

Vapour Pressure @ 25℃, mbar .........................................................................................1-2

Density @ 25℃ , g/cm3 [ISO 1675] .........................................................................0.95-1.05

Storage life @ 25℃ (sealed container), month ……………………………………………………………...12

Process parameters(guideline values)*

System:JT 8218A / JT 8218B

TYPICAL VALUES*

JT 8218A Epoxy resin ……………………………………….....................................................100 pbw

JT 8218B Epoxy hardener……………………………………….................................................25 pbw


TYPICAL VALUES*

Initial Mixed Viscosity @ 40℃, mPa.s [ISO 2555] ..................................................1500-3000


Gel time, 25℃, Gelnorm instrument, minute ................................................................30-60


*Guideline values, for reference only!


Properties(guideline values)*

Curing condition: 24 h@25℃+6h@60℃

TYPICAL VALUES*

Hardness@25°C, Shore D................................................................................................70-80


Tensile strength@, MPa.................................................................................................... >10


Flexural strength@, MPa................................................................................................... >40


Coefficient of linear thermal expansion@, ppm/K...................................................... 50-100


Thermal conductivity@, Wm/k …………………………………………………………………………………… >0.4


Dielectric strength@, kV/mm............................................................................................ >15


Dielectric constant@25°C ,50HZ...................................................................................4.0-5.0


Volume resistivity@ Wcm………………………………………………………………………………….………1X1015




Industrial hygiene

When operating and processing products, must follow the industrial hygiene standards.

For more information, please refer to the corresponding safety data sheet and .


Operating protection measures


Workplace safety measures:

Protective clothing Need

Gloves Must need

Arms to protection May contact with the skin, Recommended

Goggles/safety glasses Need

Mask/dust mask Recommended


Skin protection:

Before working To exposed skin protection by cream

After washing Frost of besmear protective cream or nutrition

Contamination of the skin clean With suction paper wipe, wash with warm water and alkali free soap, With a one-time towel dry. Do not use solvents.

Clean workshop environment Use a light paper covering the table and chairs. Using a disposable beaker, etc. Spatter material processing Use sawdust or waste cotton silk blotting, and placed in a plastic woven baskets.

Ventilation:

To workshop Take a breath three to five times per hour.

To position Cover of exhaust fan. The operator should avoid inhalation of vapour.



Application area:

My Product Line:


My Warehouse:


China 24 Hours Room Temperature Curing Epoxy Resin For Coil Frame Work Medium Viscosity supplier

24 Hours Room Temperature Curing Epoxy Resin For Coil Frame Work Medium Viscosity

Inquiry Cart 0