VKL11 ELCB Earth Leakage Circuit Breaker Type S Selective time delay


1. General


1.1 Function

Control electric circuits.

Protect people against indirect contacts and additional protection against direct contacts.

Protect installations against fire hazard due to insulation faults.

Residual current circuit breakers are used in housing, tertiary sector and industry.


1.2 Selection


Detectable wave form


ELCB TypeSuitable for electrical networks with
Pulsated DC currentHarmonicsSwitching surges
AC CLASSNoNoNo
A CLASSYesNoNo
S, ASi CLASSYesYesYes

A Class ELCB may not work satisfactorily in electrical network distributed by harmonics & switching transients and may give nuisance triping.

AC class

Tripping is ensured for slowly increasing sinusoidal AC residual currents


A class

Tripping is ensured for sinusoidal AC residual currents and for pulsed DC residual currents, whether applied suddenly or increasing slowly.


ASi Type - Full type A features + Si: Super immused (High immunity to unwanted tripping)

Tripping is ensured not only for sinusoidal AC residual currents but also for pulsed DC residual currents whether applied suddenly or increasing slowly. S, G/SI type with filters against spurious tripping caused by harmonics and transient surges. With the impact of 8/20us surge 3000A, this high immunity RCCB will still be in stable status.

Note: Our ASi type includes G/KV function and Si function.


1.3 Approvals and certificates

We certify that the RCCB has been tested for the following routine tests as per IS: 12640 (Part 1):2016 and found to be complying

with the requirements.

1. Verification of the operating characteristic as per Seq. - D0 CL9.9

2. Verification of the operation of the test device at the limits of rated voltage as per Seq. - D1 CL9.16

3. High Voltage Test as per D.3 of Annex D

4. Test for standard values of break time and non- actuating time as per CL 5.3.12 (table -1)

Tripping sensitivity

10mA - precision instrument leakage protection and bathroom use.

30mA - additional protection against direct contact.

100mA - co-ordinated with the earth system according to the formula I△n < 50/R, to provide protection against indirect contacts;

300mA/500mA - protection against indirect contacts, as well as fire hazard.

Tripping time

Instantaneous

It ensures instantaneous tripping(without time-delay).

Short time delay Si, G, KV

It ensures any tripping at least 10ms.

Si: Super immunised (High immunity to unwanted tripping).

Selective

It ensures total discrimination with a non selective ELCB(RCCB) placed downstream.


ELCB | Earth Leakage Circuit Breaker


2. Technical parameters

StandardIEC/EN 61008-1 AS/NZS61008.1
Electrical featuresModel No.VKL11
Poles2P, 4P
Rated current In16A, 25A, 32A, 40A, 63A, 80A, 100A
Rated Sensitivity I△n10mA(2P/4P 16A,25A.32A/40A), 30mA, 100mA, 300mA
Rated voltage Ue2P: 240V 4P: 415V
Insulation voltage Ui415V
Rated frequency50/60 Hz
Rated residual making and breaking capacity I△m1500A
Short-circuit current Inc=I△c6000A, 10000A
Type (wave form of the earth leakage sensed)AC, A, ASi, S
break time under I△n≤0.1s(Normal type), 10ms~300ms(ASi type). 150ms~500ms(S type)
Rated impulse withstand voltage(1.2/50) Uimp4kV
Dielectric test voltage at ind. Freq. for 1 min2.5
Pollution degree2
Mechanical featuresElectrical life≥2000
Mechanical life≥2000
Fault current indicatorYes
Terminal protection degreeIP20

Ambient temperature (with

daily average≤35℃)

-25℃ to 50℃
Storage temperate-30℃ to 70℃
InstallationTerminal connection typeCable/Pin-type busbar
Terminal size top/bottom for cable25-35 mm²
18-3/18-2 AWG
Terminal size top/bottom for busbar10/16 mm²
18-8/18-5 AWG
Tightening torque2.5 N·m
22 In-Ibs.
MountingOn DIN rail EN 60715 (35mm) by means of fast clip device
ConnectionFrom top and bottom

3. Outline and installation dimensions (mm)


ELCB | Earth Leakage Circuit Breaker

Product Description:

ELCB TYPE S Earth Leakage Circuit Breaker is an electrical device designed to protect against electrical shocks caused by earth leakage. It is commonly used in commercial and industrial settings. It works by tripping the circuit breaker when the current leakage to earth exceeds a certain threshold or set level. This product features dimension according to the product model, material PA66, trip time ≤ 0.1s, rated sensitivity 30mA/100mA/300mA and protection grade IP20. It is perfect for protecting you and your family from electric shocks. ELCB Type S Earth Leakage Circuit Breaker is an effective and reliable protective device, ensuring safety and peace of mind.

Features:

  • Product Name: ELCB Earth Leakage Circuit Breaker
  • Insulation Voltage: ≥2KV
  • Rated Current: 6A-100A
  • Rated Voltage: 240V/415V
  • Material: PA66
  • Protection Grade: IP20
  • ELCB TYPE: ELCB Type A Type AC Type ASi (TYPE S SELECTIVE TIME DELAY)

Applications:

ELCB Type EV Earth Leakage Circuit Breaker is a reliable and efficient protection device for electrical safety. HAROK VKL11 ELCB UL1053 is a top-notch product of its kind, with a rated current of 6A-100A, insulation voltage of ≥2KV, protection grade IP20, and trip time ≤0.1s. It is certified by NF, SEMKO, VDE, KEMA, and the minimum order quantity is 1000. Packaging is paper carton and shipping takes 4-6 weeks after payment. FOB NINGBO or SHANGHAI is offered as payment terms. The supply ability is 100,000 PCS PER MONTH and the dimension is according to the product model.

Technical Parameters:

ParameterDetails
ELCB TypeA Type AC Type ASi
Rated Voltage240V/415V
MaterialPA66
Operating Environment Temperature-25℃~+50℃
Protection GradeIP20
Insulation Voltage≥2KV
WeightAccording To The Product Model
Rated Frequency50/60Hz
DimensionAccording To The Product Model
Trip Time≤0.1s
Rated Sensitivity30mA/100mA/300mA

Customization:

ELCB Earth Leakage Circuit Breaker

Brand Name: HAROK
Model Number: VKL11
Place of Origin: CHINA
Certification: NF, SEMKO, VDE, KEMA
Minimum Order Quantity: 1000
Packaging Details: PAPER CARTON
Delivery Time: 4-6 weeks after payment
Payment Terms: FOB NINGBO or SHANGHAI
Supply Ability: 100,000 PCS PER MONTH
Trip Time: ≤0.1s
Rated Voltage: 240V/415V
Installation Method: Cable/Pin-type busbar
Weight: According To The Product Model

Packing and Shipping:

ELCB Earth Leakage Circuit Breaker Packaging and Shipping

Packaging:

  1. ELCB Earth Leakage Circuit Breaker will be packaged in a standard cardboard box.
  2. The box will be taped securely with a strong packing tape.
  3. The box will be labeled with a corresponding barcode and a product description.

Shipping:

  1. ELCB Earth Leakage Circuit Breaker will be shipped via a third-party shipping provider.
  2. The shipping provider will be chosen based on cost, delivery time, and availability.
  3. The package will be insured for the full value of the product.

China VKL11 ELCB Earth Leakage Circuit Breaker Type S Selective Time Delay supplier

VKL11 ELCB Earth Leakage Circuit Breaker Type S Selective Time Delay

Inquiry Cart 0