High Voltage Disconnect Switch GW9-10 Series 1250A Vaccum Disconnector Used With Circuit Breaker For Outdoor
Product Description:
GW9-10 Series high voltage disconnect switch is an electrical switch used in high voltage power systems to isolate or disconnect a section of the system from the rest of the system. It is designed to operate under high voltage and current conditions and is used primarily for maintenance, repair, or emergency situations.
The switch consists of a set of contacts that can be opened or closed by a mechanism, such as a manual or motorized actuator. When the switch is closed, it allows electrical current to flow through the system, while when it is open, the current is interrupted, and the system is effectively disconnected.
Application:
1 Substation isolation: In a substation, high voltage disconnector switches are used to
disconnect transformers, circuit breakers, and other equipment from
the power system for maintenance or repair.
2 Transmission line isolation: High voltage disconnector switches are used to isolate sections of
a high voltage transmission line for maintenance, repair, or to
prevent power flow during emergencies.
3 Capacitor bank switching: In power systems with capacitor banks, high voltage disconnector
switches are used to disconnect the capacitor bank from the power
system for maintenance or repair.
4 Load shedding: In case of an overload or other emergency situation, high voltage
disconnector switches can be used to shed load by disconnecting
certain sections of the power system.
5 Fault isolation: High voltage disconnector switches are used to isolate faulted
sections of the power system to prevent damage to equipment and
ensure continuity of power supply.
Conditions:
Technical Parameters:
Serial No. | Parameter | Unit | Data | |||||||||
1 | Rated Voltage | kV | 12 | |||||||||
2 | Rated Current | Model No. | (H)GW9-12(W)/630-20 | A | 630 | |||||||
(H)GW9-12(W)/1000-20 | 1000 | |||||||||||
(H)GW9-12(W)/1250-31.5 | 1250 | |||||||||||
3 | 4s Short-time withstanding current | Model No. | (H)GW9-12(W)/630-20 | kA | 50 | |||||||
(H)GW9-12(W)/1000-20 | 50 | |||||||||||
(H)GW9-12(W)/1250-31.5 | 80 | |||||||||||
4 | Rated Insulation Level | Lightning surge withstand voltage(peak) | Polar-to-Earth (Positive & Negative) | kV | 75 | |||||||
Interfracture (Positive & Negative) | 85 | |||||||||||
Industrial frequency withstand voltage (1 min) (Effective value) | Dry Test/Wet Test | Polar-to-Earth | 42(Dry) 34(Wet) | |||||||||
Interfracture | 48(Dry) | |||||||||||
48(Dry) | ||||||||||||
48(Dry) 40(Wet) | ||||||||||||
5 | Main Circuit Resistance | μ Ω | 630 | |||||||||
1000 | ||||||||||||
1250 | ||||||||||||
6 | Mechanical Life Time | times | 50 | |||||||||
50 | ||||||||||||
80 |