

Add to Cart
Frame Material | Hardpressed Aluminum Alloy T6061/T6 | |||
Roof | 850g/sqm white PVC Fabric | |||
Sidewall | 650g/sqm white PVC Fabric | |||
OEM/ODM | Available | |||
Application | Wedding,Banquet,Ceremony,Party | |||
Span Width | Bay distance | Side height | Ridge height | Eave Height |
3M | 3M | 2.6M | 3.1M | 84X48X3mm |
4M | 3M | 2.6M | 3.3M | 84X48X3mm |
5M | 3M | 2.6M | 3.5M | 84X48X3mm |
6-8M | 3M | 2.6M | 3.6M-3.8M-4M | 84X48X3mm |
10-12M | 5M | 4M | 5.7M-6M | 122X68X3mm |
13-15M | 5M | 4M | 6.2M-6.5M | 166X88X3mm |
16-20-23M | 5M | 4M | 6.6M-7.2M-7.6M | 203X112X4mm |
24-25M | 5M | 4M | 7.8M-8M | 203X112X4mm |
>25M | 5M | 4M | 8-13.1M | 256X120X5mm/300X125X6mm/350X125X6mm |
1.1 In order to standardize the construction of temporary tents for
the exhibition, meet the use function, reliable technology, safe
and applicable,
Economical and reasonable, to ensure the quality of the project and
the use of safety, the formulation of this regulation.
1.2 This standard applies to the single layer with a span of no
more than 40m used in temporary rooms of exhibition projects
Tent design, manufacture, installation, use and maintenance. When
the monomer span is greater than 40m, or the height is greater than
2
Layer (including 2 layers) and if there are special requirements,
experts should be organized to conduct safety demonstration.
1.3 In addition to this standard, the application of temporary
tents should also meet the current national and local standards
Standard and normative requirements.
2.1 Tent
Reusable, movable, closed or open temporarily installed structural
buildings, consisting of support structures and enclosures
Protective structure composition.
2.2 Structural Components
The main force components of the tent, such as: beams, columns,
plates, supports, stairs, platforms and other components.
2.3 Enclosure Structure
Enclosures on all sides of the tent, such as walls, roofs, doors
and Windows.
2.4 Membrane material
A composite material consisting of a high-strength fabric substrate
and a polymer coating.
3.1 Qualification documents: The tent should have factory
qualification documents or relevant test reports. Certificate of
conformity
The documents shall indicate the product model specification, batch
number, manufacturer name, production year, technical verification
agency,
Combustion characteristics and other necessary information.
3.2 The design, manufacture and installation of the tent must
ensure the safety of the structure.
3.3 The materials used in the enclosure structure and interior
decoration of the tent must meet the fire protection grade B1 and
above.
Safety cables for pillar structures must be made of non-combustible
materials.
3.4 When the span of the canopy is less than or equal to 12m, the
wind resistance performance is not less than 60km/h wind
resistance. tent
When the span is greater than 12m, the wind resistance is not less
than 80km/h wind resistance.
3.5 The tent should have adequate energy saving measures.
3.6 Waterproof and drainage measures should be considered according
to the needs of the tent.