JLSF-10HP Air Cooled Water Chiller Crusher, Granulator, Extruder, Bottle Blowing Machine


Product Description:


Air-cooled chiller is a kind of chiller equipment, also known as chiller. It discharges heat by using an air condenser, so it is called "air-cooled", which is different from the way water-cooled chillers work, which uses a water condenser to discharge heat.

Compared with the traditional water-cooled chiller, the difference between the air-cooled chiller and the traditional water-cooled chiller is that it uses an air cooler as a condenser, and the fan blows the air required for heat dissipation from one side of the machine and exhausts it from the other side. Achieve cooling. Therefore, the air-cooled chiller does not need an external cooling water source, is independent, and is very convenient to install and move.




Production Features:


Air-cooled chiller is a common refrigeration equipment, its main features are as follows:


1.Independence: The air-cooled chiller does not need to be connected to an external cooling water source through pipes or water pumps. It is independent and easy to install and move.


2.High efficiency and energy saving: The air-cooled chiller adopts high-efficiency compressors and heat exchangers, which can reach the set temperature requirements in a short period of time, and can also reduce energy consumption and have better energy-saving effects.


3.Easy maintenance: The air-cooled chiller is simple in structure, easy to maintain, easy to clean and repair.


4.Low noise: The air-cooled chiller has low operating noise and will not interfere with the surrounding environment and personnel. It is suitable for places that require a quiet environment.


5.Automatic control: The air-cooled chiller adopts an advanced control system, which can automatically adjust the temperature and humidity to ensure stable and reliable cooling effect.


6.Flexibility: The air-cooled chiller can be used alone or in conjunction with other equipment to meet different needs.


In general, the air-cooled chiller has the characteristics of independence, high efficiency and energy saving, easy maintenance, low noise, automatic control and flexibility, and is an ideal equipment widely used in various refrigeration needs.


Working Principle:


The main components of an air-cooled chiller include a compressor, an air condenser, an expansion valve, and an evaporator. Here is a basic overview of its workflow:

1.The compressor takes in low-pressure, low-temperature refrigerant gas and compresses it into high-pressure, high-temperature gas.

2.This high-temperature, high-pressure refrigerant gas enters the air condenser, exchanges heat with the ambient air, and discharges heat to the environment, while the refrigerant condenses from a gaseous state to a liquid state.

3.The high-pressure refrigerant liquid passes through the expansion valve, the pressure suddenly drops, and it turns into a low-pressure and low-temperature refrigerant liquid.

4.The low-temperature and low-pressure refrigerant liquid enters the evaporator, absorbs indoor heat, evaporates into a gaseous state by itself, and the indoor temperature drops to achieve the purpose of refrigeration.

5.The refrigerant gas is sucked into the compressor again to complete a cycle.

The advantages of air-cooled chillers include simple installation, no need for cooling towers and cooling water pumps, and low maintenance costs. However, its efficiency is lower than that of water-cooled chillers, especially at high ambient temperatures, and its efficiency will be further reduced

① Compressor⑤ Evaporator⑨ Temperature sensor⑬ Bypass valve
② Condenser⑥ Ball valve⑩ Water tank⑭ Low voltage controller
③ Filter drier⑦ Antifreeze switch⑪ Water pump pressure gauge⑮ High voltage controller
④ Expansion valve⑧ Float switch⑫ Water pump

⑯ Pressure relief valve


Techinical Parameters:


ModelJLSF-1HPJLSF-2HPJLSF-3HPJLSF-4HPJLSF-5HPJLSF-6HPJLSF-8HPJLSF-10HP
Cooling capacityKW/h3.16.29.312.415.518.624.831
Kcal/h2,7005,4008,10010,80013,50016,20021,60027,000
Temperature range5℃-35℃(Below 0℃ can be customized)
Power supply1PH-220V 50HZ/60HZ 3PH-380V/415V 50HZ/60HZ
Total powerKW1.212.032.843.74.55.77.338.83
CompressorTypeHermetic scroll type or piston
PowerKW0.751.502.253.003.754.506.007.50
Circulating pumpPowerKW0.3750.3750.3750.3750.750.750.751.5
Headm2222222223232321.5
RefrigerantTypeR22/R407c/R134a/R410a
Control methodTemperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg0.501.001.502.002.503.004.005.00
EvaporatorFlowm³/h0.820.981.451.882.422.923.754.85
water capacity0.0280.040.050.050.0650.0650.130.18
Diameterinch1/2"3/4"1"1-1/2"1-1/2"
CondensatorTypeEfficient brass sets corrugated aluminum fin
FanTypeAxial flow
air volumem³/h100020003000400050006000800010000
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm680800104011401140120014001400
Wmm420480555620620650725725
Hmm720850106012001200116014501450
Unit weightKg6090130140170210270350

ModelJLSF-12HPJLSF-15HPJLSF-20HPJLSF-25HPJLSF-30HPJLSF-40HPJLSF-50HPJLSF-60HP
Cooling capacityKW/h37.246.56577.593124155186
Kcal/h29,05937,96550,80561,68374,99297,675116,521156,249
Temperature range5℃-35℃(Below 0℃ can be customized)
Power supply1N-220V 50HZ/60HZ 3N-380V/415V 50HZ/60HZ
Total powerKW11.413.6219.822.7528.339.246.7556.1
CompressorTypeHermetic scroll type or piston
PowerKW911.251518.7522.53037.545
Circulating pumpPowerKW1.51.52.22.24445.5
Headm21.521.5222225252526
RefrigerantTypeR22/R407c/R134a/R410a
Control methodTemperature Sensing External Pressure Equalizing Expansion Valve
filling volumeKg7.29.112.215.318.624.530.636.8
EvaporatorFlowm³/h5.817.610.1612.3415.219.5323.330.52
water capacitym³/h0.180.210.280.320.320.610.660.72
Diameterinch1.5"2"2.5"3"
CondensatorTypeEfficient brass sets corrugated aluminum fin
FanTypeAxial flow
air volumem³/h1200015000200002500030000400005000060000
Protective deviceHigh and low pressure switch, antifreeze protection, fusible plug/safety valve, overload protection device, coil overheat protector, automatic temperature protection switch, etc.
Machine sizeLmm14001750200020002200200020002400
Wmm725750900900900180018001800
Hmm14501500177017701770220023002300
Unit weightKg370480590590880100012801420


Application Industry:


In the plastics industry, there are a wide range of applications that require the use of chillers. The following are some common applications:


1. Injection molding: Injection molding is a common processing method in the plastics industry. It is necessary to use a chiller to provide cooling water for the injection mold to quickly reduce the temperature of the molten plastic, speed up the molding speed and improve the molding quality.


2. Extrusion molding: Extrusion molding is a method of extruding plastic from an extruder. It is necessary to use a chiller to provide cooling water for the extruder to control the temperature of the plastic and ensure the quality of extrusion molding.


3. Blow molding: Blow molding is a method of blowing molten plastic into hollow products through a blow molding machine. It is necessary to use a chiller to provide cooling water for the blow mold to quickly reduce the temperature of the plastic and speed up molding. and improve molding quality.


4. Plastic film production: Plastic film production requires the use of chillers to provide cooling water for the extruder and die in the production line to control the temperature of the plastic and ensure the quality of the film.


5. Plastic foam production: Plastic foam production requires the use of chillers to provide cooling water for the foaming machines in the production line to control the temperature of the plastic and ensure the quality of the foam.


In general, chillers are used in a wide range of applications in the plastics industry, which can provide stable refrigeration services for plastic production, improve production efficiency and reduce production costs.



Automotive Manufacturing Chemical Engineering Electronics Industry Electroplating Industry

Injection Molding Industry Pharmaceutical Industry Plastic Packaging Industry Printing Industry



Upport and Services:


Air Cooled Chiller technical support and service includes:

1. 24/7 customer support
2. Remote guidance installation and maintenance
3. Remote Diagnostics and Troubleshooting
4. Phone/Email Advice and Guidance
5. User friendly documentation and manuals
6. Software Updates and Upgrades
7. Cost price of spare parts and consumables


Packing and Shipping:


Air-cooled chillers are packaged and shipped in standard plywood wooden boxes. All components are secured and protected with a film, and the unit is then placed on a pallet for easy transport. And affix the shipping mark information label on the wooden box to ensure correct delivery.


Comprehensive selection method and skill of industrial chiller


The selection of industrial chillers needs to consider many factors. The following are some comprehensive selection methods and skills:

1. Determine the cooling load: the cooling load is the basis of model selection and needs to be determined according to the specific application. Generally speaking, the cooling load includes the heat load of the room and the heat load of the equipment.


2. Select refrigerant: Refrigerant selection needs to consider factors such as refrigeration efficiency, environmental protection, and safety. Commonly used refrigerants include Freon, propane, and CO2.


3. Select the cooling method: There are two types of cooling methods: air-cooled and water-cooled, which need to be selected according to the specific application and cooling load.


4. Determine the refrigerant recovery method: Recycling refrigerant can reduce environmental pollution and energy waste, and air source heat pumps, waste heat recovery devices and other equipment can be used to achieve this.


5. Select the brand and model: To determine the brand and model based on the above factors, factors such as performance, quality and after-sales service need to be considered.


6. Economic considerations: In addition to the above factors, economics should also be considered when selecting models, including factors such as equipment price, service life, energy consumption, and maintenance costs.


7. Refer to the experience of other users: You can refer to the experience of other users to understand the actual use effect and problems of the equipment, and make reference and learn from them.


Combining the above factors, choosing a suitable industrial chiller can improve production efficiency and save energy, and achieve better economic and environmental benefits.


China JLSF-10HP Industrial Air Cooled Chiller For Crusher Granulator Extruder supplier

JLSF-10HP Industrial Air Cooled Chiller For Crusher Granulator Extruder

Inquiry Cart 0