TTR-I Automatic Transformer Turns Ratio Tester Transformer Testing Equipment

Brand Name:Delta
Certification:ISO9001
Model Number:TTR-I
Minimum Order Quantity:1 set Turns Ratio Test Set
Delivery Time:10 days
Payment Terms:T/T, Western Union
Contact Now

Add to Cart

Verified Supplier
Location: Chongqing Chongqing China
Address: No.85 Zhong Shan Yi Road, Yu Zhong District, Chongqing, China. 400010
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

TTR-I Automatic Transformer Turns Ratio Tester Transformer Testing Equipment

Introduction:

  • TTR-I Automatic Transformer Turns Ratio Tester Transformer Testing Equipment is designed according IEC76-1 and IEC60044.
  • TTR-I Automatic Transformer Turns Ratio Tester Transformer Testing Equipment can be applied to test the turns ratio and group vector of single or three phase transformer.
  • The connection group of three phase transformer also can be calculated with the ratio.
  • All parameters can be measured in one test for three phase transformer.

Functions:

  • Turns ratio testing: single phase power transformer, three phase power transformer, CT, PT;
  • Phase angle testing:single phase power transformer, three phase power transformer, CT,PT;
  • Polarity testing: single phase power transformer, three phase power transformer, CT, PT;
  • Vector group testing: three phase power transformer;

Features:

  • 1200°C Split-Hinge Tube Furnaces for horizontal use.
  • Heating element modules for superior radial and linear temperature uniformity and fast heat up and cool down.
  • Long-life, energy-efficient elements require little or no maintenance.
  • Mode conversion switch (Test method of IEC 60754-1&2 could be selected).
  • Alarm Temperature Controller: Temp controller to protect overheating of furnace.
  • Quartz work tube and sample lading assembly.
  • pH and conductivity measuring instruments with digital display and electrodes Stirrer.
  • Mass flow meter control the flow rate of air and digital display.
  • Activated Charcoal (air filtering): Filter for filtering the supplied air (activated charcoal).
  • Silica Gel (air drying): Device for drying the supplied air.
  • 100 ceramic sample boats.

Parameters:

No.Item NameTTR-I Automatic Transformer Turns Ratio Tester Transformer Testing Equipment
1Ratio measurement range1-10000
2Group measurement1-12
3Phase measurement error1 degree
4Ratio measurement error1-2000 ± 0.2%RDG 2000-10000 ± 0.5%RDG
5Test voltageAC 0~80V continuously, frequency 50Hz
6Power supplyAC220V ± 10%, 50Hz/60Hz
7Environment temperature0-50°C
8Humidity≤85%RH
9Size400mm*350mm*200 mm
10Weight7kg
11Length of test cables8 meters

TTR-I Transformer Testing Equipment Real Picture:

China TTR-I Automatic Transformer Turns Ratio Tester Transformer Testing Equipment supplier

TTR-I Automatic Transformer Turns Ratio Tester Transformer Testing Equipment

Inquiry Cart 0