Product Details

Atomic Absorption Spectrophotometer AAS Analyzer


Features:

  • Build-in computer data processing and LCD
  • Good basic line stability
  • High precision of measurement
  • Optical path of high energy
  • Long-life and anti-corrosive atomization system
  • Multi-functional analysis mode
  • Safe and reliable gas path system

Specifications:

Working spectral range190-900nm
Wavelength accuracy≤ ±0.5nm
Wavelength repeatability≤ 0.3nm (single direction)
Spectrum bandwidth0.2nm, 0.4nm, 0.7nm, 1.4nm, 2.4nm, 5.0nm
Resolution<40%
Base line stability±0.004Abs/30min
Characteristic concentration of copper≤ 0.04mg/ml/1%
Detection limit of copper≤0.008mg/ml
Background calibration abilityGreater than 30 times
Standby InterfaceRS 232
Instrument power supply220V, 3A, 50Hz

Complete set of accessories:

Light-source system

Hollow cathode lamp power supply: with adjustable current Deuterium Lamp power supply: with fixed current


Optical system

Double beam total refection system, C-T type monochromator Flashing wavelength: 250nm


Flame atomization system

Inter-changeable titanium alloy burner of 10cm and 5cm slits. Gas path is equipped with pressure indication, high precision voltage stabilizing flow adjustment, fast conversion of air and nitrous oxide, gas supply cut off, power cut off, prevention of flashback and logic interlock protection devices.


Signal processing

Absorptance, concentration, emission and emission concentration; Standard curves: linear regression, curve fitting and multi-point standard calibration. Average value, standard deviation, relative standard deviation and correlation coefficient can be worked out. Standard curves, atomic absorption peak diagram, spectrum outline sketch, data as well as instrument parameters list and analytical reports can be displayed and printed out.