Product Details
ASTM F1930 Manikin Flame Engulfment Test Apparatus
Introduction:
- The Manikin Flame Engulfment Test Apparatus conforms to iso13506 and ASTM F1930 standards.
- To empirically evaluate the performance of a garment in a simulated
flash fire environment that controls the heat flux, flame
distribution and duration of the flame test manikin.
- To analyze the burn range and measure the time of 2nd and 3rd
degree burn using this system."
About System:
- It is composed of test chamber,control system, manikin, data
acquisition system, image acquisition system and software.
- It can calibrate the uniformity of incident heat flow, collect and
calculate the temperature of epidermis, dermis and subcutaneous
tissue, complete the analysis of first degree burn, second degree
burn and pain, predict the degree and scope of burn, so as to
complete the protection clothing definition of protective
properties.
Manikin:
- The test meets the requirements of ISO 13506 and ASTM f1930, and
the manikin size meets the requirements of ASTM d6240;
- The manikin model is made of non degradable and fireproof ceramic
composites;
- The manikin has joints of shoulder, elbow, knee and ankle;
- The connecting cable is connected into the manikin body from the
top of the head or the back neck;
- 122 sensors were distributed throughout the manikin;
Sensors:
- The sensor is made of copper alloy, and thermocouple is welded on
the back of sensor to measure the temperature change of copper
plate;
- The thermal radiation range is at least 0-167kw / m2;
- The sensor surface is sprayed with black high temperature resistant
paint;
- The response time of thermal sensor is less than or equal to 0.1s;
Test chamber:
- The test chamber is constructed of fire-resistant quartz glass and
steel structure. The volume of chamber is 4m long x 3.5m wide x 3m
high;
- The chamber provides a uniform flame for the test surface of the
manikin and provides sufficient space for debugging;
- The chamber shall be provided with independent ventilation
equipment to ensure sufficient oxygen supply during the test, and
exhaust gas shall be drained after the test;
- The exhaust rate of fan is adjustable, and the exhaust air volume
is at least 25m3 / min; it can also provide cooling air with
smaller exhaust air volume;
- Combustible gas leakage detector and door opening and closing
detector are equipped in combustion chamber to ensure personnel and
test safety;
Control system:
- 12 imported burner were used and divided into 6 groups, 2 in each
group
- The burner array is composed of hexagonal layout to provide uniform
incident heat flow of at least 84kw / m2 for the manikin surface;
- The gas pipeline is arranged with stainless steel pipe, and the
flame retardant hose is used to connect with the burner group;
- The inlet explosion-proof solenoid valve controls the gas on-off,
and the response time is 0.1s;
- The gas flow is controlled by mass flow controller to accurately
control the gas flow to ensure the stability and repeatability of
the fire site;
- The burner is equipped with a long open fire igniter for safe pilot
fire. During the pilot fire test, the combustion state is
maintained throughout the whole process to ensure the ignition
safety;
Data acquisition system:
- Computer + Labview realizes multi-channel high frequency data
sampling and analysis system;
- Adopt imported brand data acquisition platform and Ethernet
connection to realize time synchronization distributed measurement;
- The imported brand temperature acquisition module is adopted, the
sampling frequency is 95hz / channel, the sampling accuracy is ±
0.29 ℃, and the resolution is 0.01 ℃;
- Using Labview software platform to achieve synchronous data
acquisition, display and record;
- 124 sensors and temperature environment data are collected
synchronously;
Software:
- The system test software adopts Labview editing, modular design,
simple interface and rich data content;
- The temperature and heat flow of each channel can be calibrated,
and each channel sensor is equipped with a correction curve;
- 2nd degree burn calibration of sensor;
- The gas flow of each channel can be set;
- Exposure condition calibration: the manikin with sensor calibrated
is placed in a blast environment to confirm the heat flux value,
average value and standard deviation of each channel;
- 2nd degree burn area analysis of manikin surface;
- 3rd degree burn area analysis of manikin surface;
- Total burn area analysis of manikin surface;
- Total heat absorption analysis of manikin surface;
Company Profile
Delta Technology (Chongqing) Co., Ltd. is a high-tech enterprise
focusing on R&D, production, and sales of Electric Testing
Equipment and Fire Resistance Testing Equipment.
Safety is important to the electrical, construction, and
transportation industries, thus, Delta Technology aims to help
users test the safety of transformers, high-voltage switches,
cables, building materials, transportation materials, etc.
Since its establishment, the company has always adhered to the
principles of "quality assurance and service priority", through
years of development, our products sell well at home and abroad.
With the best products, best services, and best reputation, our
company is your reliable partner in testing equipment!