Product Details

BCV Electric and Optical Fibre Cable Tester Under Fire Condition IEC60332-1


Introduction:


BCV Electric and Optical Fibre Cable Tester is a series conforming to IEC 60332-3-10 (Category A~D) standards.

The test measures the expansion of vertical flame to the electronically or optically vertical cable or wire using the standard ignition source while supplying a certain amount of air to a chamber of a defined volume.

Additionally, if bunched cable vertical flame spread testers burner is adjusted by 20 degrees angle, it can be measure under IEEE 383(IEEE 1202) standard. Also, if Heat Release Facility is attached, it can measure fire dynamics value as H.R.R (Heat Release Rate), S.P.R (Smoke Production Rate) and so on.


Standards:

  • ASTM: ASTM E662

  • ISO: ISO 5659-2

  • IMO: FTPC Part 2

  • NES: NES 711


Application Field:


  • IMO;

  • Rail;

  • Wire&Cable;

Features:

Test chamber has the dimension of 1,000±100(W) x 2,000±100(D) x 4,000±100(H) mm.

The bottom surface of the test chamber is higher than the ground while the rear side is supplemented with insulated material to insulate it from heat.

At the lower section of the test chamber, there is a 800±20(W)x 400±10(D) sized hole at the 150±10mm position from the front side of the chamber to supply the air.

There is a 300±30(W)x1,000±100(D) sized exhaust hole at the rear corner of the top section of the test chamber to allow emission of the smoke during the test.

A flame trap is installed at the front side of the burner of the vertical flame spread tester to prevent backfire by propane to ensure the utmost safety.

Unlike the conventional IEC60332-3 equipment, the vertical flame spread tester records all control and test conditions with the computer to add user friendliness.

If stop the excessive combustion test due to Water Spray device installed for extinguish.

The program on the requirement on standard and 70,000Btu/h can be program.

Wide stainless steel ladder dimensions: 500(W) ×3, 500(H) mm.

Standard stainless steel ladder dimensions: 800(W) ×3, 500(H).

Two sets of standard propane burner and venturi mixtures.

Follow the standard category can program for select a test.


Parameters:


No.Item NameBCV Electric and Optical Fibre Cable Tester
1Dimension1120 mm (W) x 2200 mm (D) x 5070 mm (H)
2Weight500kg
3Power supply110V AC 60Hz / 230V AC 50Hz, 5A
4Ambient temperatureOperating 10oC to 35oC
5Gas supplyAir and propane