CPT-III Automatic CT PT Testing Equipment

Application:

Tests for current transformer:

  1. Excitation curve and parameters test
  2. Turns ratio test
  3. Ratio and phase error test
  4. Polarity mark check
  5. Winding resistance measurement
  6. Secondary loop burden measurement
  7. Error line curve test for protection CT
  8. Transient CT parameters test
  9. CT nameplate guess
  10. Saturation hysteresis loop curve measurement

Tests for voltage transformer:

  1. Turns ratio test
  2. Ratio error and phase angle error test
  3. Polarity test
  4. Secondary burden test
  5. Winding resistance test

Applications for CT PT Testing Equipment:

  • CT nameplate check
  • CT parameters check in work burden
  • CT transient parameters analysis
  • CT ratio and phase error calibration
  • PT routine test


Parameters:

No.Item NameCPT-III Automatic CT PT Testing Equipment
1Test standardsIEC60044-1, IEC60044-6, GB1208, GB16847, C57.13
2Power supplyAC220V±10%,50Hz/60Hz±10%
3Power output0.1~180V (AC)
4Current output0.001~5A(RMS)
5Power output300VA
6Max. knee voltage measurement45kv
7Current measurement range0~10A (automatically change range in 0.1/0.4/2/10A)
8Current measurement error<±0.1%+0.01%FS
9Voltage measurement range0~200 V (automatically change range in 1V/10V/70V/200V)
10Voltage measurement error< ±0.1%+0.01%FS
11Turns ratio measurement range

1~35000;

1~2000 error<0.05%;

2000~5000 error>0.1%;

5000~35000 error<0.2%

12Phase measurementerror:±2min,resolution:0.01min
13Coil resistance measurement

Range: 0~8kΩ(automatically change range in 2ohm /20ohm /80ohm/800ohm/8kohm)

Error< 0.2%RDG+0.02%FS

Maximum resolution: 0.1mΩ

14Temperature measurement-50~100 Celsius degree, error<3 Celsius degree
15CT Secondary burden

Range 0-160ohm (automatically change range in 2ohm/ 20ohm/80ohm/160ohm)

Error <0.2%RDG+0.02%FS

Maximum resolution 0.001ohm

16PT Secondary burden

Range 0-80kohm (automatically change range in 800ohm / 8kohm /80kohm)

Error <0.2%RDG+0.02%FS

Maximum resolution: 0.1ohm

17PT ratio measurement

Range: 1~35000,

1~5000 error<0.2%

5000~35000 error<0.5%

18Saved data groups>1000groups
19Work conditionTemperature:-10℃-50℃, moist:≤90%
20Size485mm×356mm×183mm
21Weight<15Kg