Capnography HP ETCO2 Sensor Mainstream For MP5 MP2 X2 M2501A

Brand Name:Med Accessories
Certification:CE,ISO,SFDA
Model Number:MCMZ30
Minimum Order Quantity:1pcs
Delivery Time:About one week
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Dongguan Guangdong China
Address: No.210,211,212,213,214,Building 1,No.12 Industry Western Road,SongShanHu,Dongguan,Guangdong,China.523808
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

M2501A Mainstream Capnography HP EtCO2 Sensor for MP5 MP2 X2

Compatibility
ManufacturerModel
HP CompatibleM3002A MMS X2, M8102A MP2, M8105A MP5
ProjectSpecifications
Principle of OperationNon-dispersive infrared(NDIR) single beam optics, dual wavelength, no moving parts.
Initialization TimeCapnogram displayed in less than 3 seconds,full specifications within 3 minutes(At 25°C).
CO2 Measurement Range0 - 114 mmHg; 0 - 15 %; 0 - 15.2 kPa.
CO2 Rise TimeRise Time Less than 80 ms - Adult Reusable or Single-Patient-Use Airway Adapter Less than 80 ms - Infant Reusable
or Single-Patient-Use Airway Adapter.
CO2 Resolution0. 1mmHg ; 0 to 38 mmHg.; 0.25 mmHg ; 39 to 114mmHg.
CO2 Accuracy0 - 40mmHg ±2 mmHg.; 41 - 76mmHg ±5% of reading.; 77 - 114 mmHg ±8% of reading.
Above 80 breaths per minute ±12% of reading. * Note: Gas emperature at 25°C.
CO2 StabilityShort term drift: Drift over four hours shall not exceed 1 mmHg maximum.
Long term drift: Accuracy specification will be maintained over a 120-hour period.
Sampling Frequency100Hz.
Respiration Rate Range3 to 150 breaths per minute.
Respiration Rate Accuracy±1 breath.
CalibrationNo routine user calibration required. An airway adapter zero is required when changing to a different style of airway
adapter.
Airway AdaptersSingle-patient-use or reusable, < 5 cc dead space (adult), < 1 cc dead space infant.
TemperatureOperating: 0 to 40°C; Storage: -40 to 70°C; Transport: -40 to 70°C.
HumidityOperating: 10 to 90% RH, non-condensing; Storage: 10 to 90% RH, non-condensing.;
Transport: 10 to 90% RH, non-condensing.
Atmospheric PressureOperating: 400-800 mmHg; Storage: 400-800 mmHg; Transport: 400-800 mmHg.
Water ResistanceIPX4 - Splash-proof - Sensor only.
Voltage Requirements5VDC ± 5 %.
Power Rating<1.0W Typical; <1.8 W Warm-up.
Sensor Weight<85g.
Sensor SizeDeep*Wide*High:48mm * 24.3mm * 35.5mm.
Cable Length2.4m.

China Capnography HP ETCO2 Sensor Mainstream For MP5 MP2 X2 M2501A supplier

Capnography HP ETCO2 Sensor Mainstream For MP5 MP2 X2 M2501A

Inquiry Cart 0