Compatibility:
Manufacturer | Model |
---|
Draeger | Narkomed 4 |
---|
MEK | MP 1000, MP 700 |
---|
Welch Allyn | 53000, 5300P, 530T0, 530TP, 53N00, 53N0P, 53NT0, 53NTP, 53S00,
53S0P, 53ST0, 53STP, Propaq Encore |
---|
FQA
Where is your factory located?
A: Our factory is situated in Dongguan
Q: Are you a trading company or do you have your own factory?
A: We have our own factory and also conduct product research.Q: How
does your factory ensure quality control?
A: Quality control is a priority for us. Our factory has a
dedicated QC department with professional quality assurance
specialists who closely monitor and control the quality of our
products from the beginning to the end of the production process.
Q: What is the typical delivery time?
A: The delivery time varies depending on the order quantity. For
trial orders, it usually takes 1-3 working days. Regular orders
typically take 3-5 working days, while bulk orders may take 7-14
working days. Please note that these are approximate timeframes and
can vary based on the specific quantity ordered.
Q: What are your payment terms?
A: We accept 100% payment in advance. Payment can be made through
various methods, including T/T (bank transfer), PayPal, Western
Union, and MoneyGram.
Cleaning the equipment:
To clean the sensor and its connecting cable, follow these steps:
Use warm soapy water: Clean the sensor and cable by gently washing
them with warm, soapy water. Ensure that the water is not too hot,
and use a mild soap or detergent.
Use a soft cloth with soapy water or 70% isopropyl alcohol: Moisten
a soft cloth with either soapy water or 70% isopropyl alcohol.
Gently wipe the probe and cable with the cloth, taking care not to
damage the surface of the visual indicator and the detector.
Avoid abrasive agents or chemical products: Do not use any abrasive
agents or chemical products except for 70% isopropyl alcohol. These
can potentially damage the sensor and its components.
Dry the probe and cable thoroughly: After cleaning, allow the probe
and cable to dry completely before using them again. Ensure that
there is no moisture remaining, as this can affect the proper
functioning of the equipment.
Avoid irradiation, autoclaving, soaking, or immersing the probe: Do
not subject the probe to irradiation, autoclaving, soaking, or
immersion in any type of solution. These actions can damage the
probe and compromise its performance.
Keep the probe clean and dry: It is important to maintain the
cleanliness and dryness of the probe during use. Regularly check
for any signs of contamination or damage and clean as necessary.
Average life expectancy: The average life expectancy of a SpO2
sensor is typically more than a year when used under the conditions
recommended in the operating instructions. Following the proper
cleaning and maintenance guidelines can help prolong the lifespan
of the sensor.