Product Details
300kw Generator Price with Cummins 6ltaa13-G3 Stamford Alternator
Enclosed Low Noise
Basic Info.
Cooling Method
Water Cooling
Output Type
AC Three Phase
Conditions of Use
Land Use
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Fuel Tank
8-9 Hours Base Fuel Tank
Model
Open Type/Silent Type/Trailer Type/Container Type
Alternator
Leroy Somer/Stamford/Stamford Copy
Transport Package
Container
Specification
40HQ Container
Production Capacity
2500/Month
Packaging & Delivery
Package Size
5800.00cm * 2500.00cm * 2400.00cm
Package Gross Weight
43000.000kg
Helpful tips on Generator Set Fault |
When fault occurs during generator set running,could do primary
judgement according to following tips. |
Icon | Indicator Light | Reason | Fault Analysis and Solve Method |
High Water Temperature Alarm | High Water Temperature Alarm | When water Temperature has risen to a level higher than or equal to
the sensor setting,the light is on. | Normally,it is caused by lack of Water or Oil Shortage,or Overload.
----Should Automatically Shutdown Generator set Immediately. |
Low Oil Pressure Alarm | Low Oil Pressure Alarm | When water Temperature has risen to a level higher than or equal to
the sensor setting,the light is on. | Normally,it is because of lack of Oil or Lubrication System Failure
which caused by refueling or replacing the Oil Filter.----- When
occurs this fault,should automatically shutdown generator set
immediately. |
Low Fuel Level Alarm | Low Fuel Level Alarm | When Fuel level has been detected by sensor fitted to the daily
tank,the light is off. | Normally,it caused by lacking of Water or Oil Shortage,or
Overload.-----When occures this Fault,should automatically shutdown
Generator set Immediately. |
Battery Charger Fault Alarm | Battery Charger Fault Alarm | The Charing System has fault while engine still running,the light
is off. | Battery Charging System Fault Caused.---The light in on at the
initial Start,when the charger reaches a certain speed,the light is
off.---This Failure will not lead to Automatic Shutdown Generating
Unit. |
Crank Failure Alarm | Crank Failure Alarm | When Generator set fail three times(or six times) in arow
starting,the light is on | It is caused by Oil Supply System or Re-Start System Failure. |
Overload or Breaker Tripping Alarm | Overload or Breaker Tripping Alarm | When Overloading or Short Circuit,the light is on. Tripping Circuit
Breaker cause generator set load out. | For this fault,it needs to load or unload some parts to eliminate
short-Circuit,and then re-close the circuit Breaker. |
I. features of silent generator setThe silent generator set is carefully designed by introducing
foreign low-noise generator and engine technology. Silent generator
set design concept advanced, complete variety.In addition to a series of diesel generating sets and various
functions of diesel generating sets, the silent generating sets
also have the following features:1. Low noise of the unit, compact overall structure and small
space;2. The box body is all removable. The box body is made of steel
plate splicing.3. The box body adopts multi-layer impedance mismatch silencer
structure and large internal impedance muffler. The box body is
designed reasonably. The box body is equipped with a large-capacity
oil tank inside, and two overhaul doors are provided at the same
time to facilitate the unit's fault maintenance.4. At the same time, there are observation Windows and emergency
shutdown buttons of the unit on the box body, so as to observe the
operation of the unit and stop the unit at a faster speed in case
of emergency to avoid damage to the unitFeatures of silent generator:1. Vibration damping facilities. High-performance shock absorbers
are used between the diesel engine and generator and the bridge
frame to reduce noise generated by vibration.2. Sound insulation cover: the sound insulation cover is made of
four to five layers of sound absorbing materials. The technology is
mature and the sound insulation effect is obvious.3. The inlet wind silencer, a labyrinth air silencer with three
layers of sound-absorbing materials, not only ensures sufficient
entrance of fresh air, but also effectively seals off the noise.4. Exhaust air silencer, a labyrinth exhaust silencer with
three-layer sound-absorbing materials, not only ensures
unobstructed exhaust air, but also effectively seals off noise
propagation and diffusion.5. The adoption of exhaust muffler and impedance composite muffler
greatly reduces the noise when the exhaust gas is discharged, and
the emission can meet the national standards.6. Power cable connection adopts fixed junction box structure and
is directly connected outside the box.Detailed parameters of the silent generator setThe complete set of units is generally composed of diesel engine,
generator, control box, fuel tank, storage battery for starting and
control, protective device and emergency cabinet
Connection between engine and generator:1. Flexible connection (connect the two parts with a coupling)2. Steel connection: high-strength bolts connect the generator's
steel connection piece with the engine flywheel, and then put it on
the common base frame, which is then equipped with various
protective sensors (oil probe, water temperature probe, oil
pressure probe, etc.) to display various transmission by the
control systemThe working state of the sensor.The control system is connected to the generator and sensor by
cable to display data.Iii. Working principle of silent generator setA diesel engine drives a generator that turns diesel energy into
electricity.In the diesel engine cylinder, the clean air filtered by the air
filter is fully mixed with the high-pressure atomized diesel
injected by the fuel injection nozzle. Under the upward extrusion
of the piston, the volume is reduced and the temperature is rapidly
increased to reach the burning point of diesel. Diesel is ignited,
the mixture burns violently, and the volume expands rapidly,
pushing the piston down, known as' work '.Each cylinder works in a certain order, and the thrust acting on
the piston through the connecting rod becomes the force that drives
the crankshaft to rotate, thus driving the crankshaft to rotate.When the brushless synchronous alternator is installed with the
crankshaft of the diesel engine, the rotation of the diesel engine
can be used to drive the rotor of the generator. With the principle
of "electromagnetic induction", the generator can output the
induced electromotive force, and the closed load loop can generate
the current.The basic operating principles of a generator set are described
here only. A range of diesel and generator controls, protective
devices and loops are needed to achieve a reliable and reliable
electrical output.If run for more than 12 h, its power output will be lower than the
rated power of diesel engine is generally about 90% diesel
generator single cylinder or multi cylinder four stroke diesel
engine, I only work about single cylinder four stroke diesel engine
under the basic principle: diesel engine starting is through human
or other power rotation diesel engine crankshaft to the piston at
the top of airtight cylinder reciprocating movement up and down.
The piston in motion completes four stroke: intake stroke,
compression stroke, combustion and work (expansion) stroke and
exhaust stroke. When the piston moves from top to bottom, the
intake valve opens and fresh air filtered by the air filter enters
the cylinder to complete the intake stroke. The piston moves from
the bottom up, the inlet and exhaust doors are closed, the air is
compressed, the temperature and pressure are increased, and the
compression process is completed. When the piston is about to reach
the top, the injector sprays the filtered fuel into the combustor
in a mist form and mixes it with the high-temperature and
high-pressure air, and immediately catches fire by itself. The
high-pressure pressure pushes the piston to work downward and
drives the crankshaft to rotate to complete the work stroke.Iv. Mute generator set operation method
Description of diesel generator set: manual operation1. Check the proper amount of fuel, oil and cooling water before
starting the diesel generator set manually. The inadequate should
be timely supplement. The unit should be free of oil leakage and
water leakage.2. The automatic control button of the automatic controller of
diesel generator set shall be pushed to the middle position.3. Open the key of the startup circuit, and continue to twist the
key to start the diesel engine to the right. After successful
startup, return the key to the charging position.4. When the diesel generating set is shut down, the key shall be
put back to the middle position of the diesel generating set in
timeAutomatic operation1. Under normal power supply conditions, push the automatic control
button of the automatic controller upward to the "automatic"
position. Manual starting of the diesel engine is prohibited. When
the power is cut off, the diesel generator set can start
automatically and supply power to the grid automatically via the
ATS switch.2. After the diesel generator sets start operation automatically,
the key switch shall be pressed to the charging position in time.3. The unit can stop automatically when the power supply calls.
After the shutdown, the key switch should be set to the middle
position to prevent the battery from discharging, affecting the
next use of diesel generator set instructions: maintenance1. After 60 hours of operation, the diesel generator set needs to
replace the oil, clean the wood filter and empty filter.2. The electrolyte of the battery should be regularly checked, and
it should be replenished in time if it is insufficient.3. Check the belt tightness frequently, adjust the tensioning
mechanism and keep the tension state.4. Turn on the water heating and oil heating switch in cold season
to keep the unit at a certain temperature and ensure the normal
operation of the diesel generatorFive, silent generator set four stroke combustion processCombustion process:1. Combustion preparation stage (flame retardation stage)The period of preparation for combustion from the injection of fuel
to the onset of fire. In this stage, the fuel requires physical
preparation such as heating, evaporation, diffusion and mixing with
airflow, as well as chemical preparation such as decomposition and
oxidation.2. Rapid combustion phaseThe period from the point of fire to the point of high pressure in
the cylinder. When a small amount of diesel oil catches fire, the
number of combustible mixture continues to increase and the flame
spreads rapidly, the combustion speed is accelerated and the heat
release rate is high. The pressure and temperature in the cylinder
increased sharply. However, if the pressure rises too fast, the
crank-link mechanism will be subjected to a great impact load,
accompanied by sharp percussion sound, and the diesel engine works
rough blasting, which should be restricted. In order to make diesel
engine work smoothly, the growth rate of pressure shall not exceed
292 kpa to 588 kpa / 1 ° (crank Angle)3. Primary stage (slow burning period)The main combustion stage is the stage between the explosion
pressure occurrence point and the high combustion temperature
occurrence point. This stage is characterized by the end of the
fuel injection, during which most of the fuel is burned, giving off
about 80% of the total heat, and the gas temperature rises to a
high point. However, as the piston moves down, the cylinder volume
increases, so the pressure in the cylinder does not change much.
The oil supply ends at this stage.4. Post-combustion stageThe period from the point of high combustion temperature to the end
of combustion. At this stage, has a large number of oxygen
consumption, fuel injection, no late enough oxygen mixture for
combustion, combined with further down, the piston within the
cylinder pressure and temperature have a larger decline, the
combustion condition worsened, so that the fuel combustion is
incomplete, appear exhaust smoke phenomenon, make relevant parts
heat load increases, affect the efficiency and service life, so try
to reduce combustion period after burningThe noise source and processing method of the silent generator setGenerator noise includes electromagnetic noise caused by magnetic
pulsation between stator and rotor and mechanical noise generated
by rolling bearing rotationNoise control measuresOn the premise of ensuring that the ventilation condition of diesel
generator sets does not reduce the output power, the inlet and
outlet channels and exhaust systems are processed with efficient
sound absorbing materials and noise-cancelling equipment, so that
the noise emission reaches the national standard of 85db.Reduce exhaust noise.Exhaust noise is the main noise source of the unit, which is
characterized by high noise level and fast exhaust speed.Governance is difficult. With a specially designed impedance
composite muffler, the exhaust noise can generally be reduced by
40-60db.Noise reduction of axial-flow fan.When reducing the noise of generator cooling fan, two problems must
be considered. The second is the required amount of silencing. For
the above two points, resistance can be selectedThe air inlet of the blade muffler shall be arranged in the same
line as the generator set and the air outlet. The air inlet shall
be equipped with resistance blade muffler. As the pressure loss of
the air inlet is within the allowable range, the air flow in and
out of the machine room can be naturally balanced and the
ventilation and heat dissipation effect is obvious.The indoor air communication and sound insulation of the machine
room will prevent the air in the room from convection when the
closed water-cooled generator is shut down, and the high
temperature in the room cannot be lowered in time. The low-noise
axial-flow fan can be adopted and the resistive blade muffler can
be added.Welcome your sending inquiry and directly contact!
Company Profile
Weifang Fengmao Power Equipment Co, Ltd professioinal in diesel
generator for years. Have fully experience send to different
countries.
Adopt famous brand engines like
Cummins/Weichai/Yuchai/Weifang/Shangchai/Jichai/Ricardo/Deutz/Steyr
etc.
Production capacity from 5kw to 2000kw.
Production types: Closed Silent/ATS/Trailer/Weatherproof etc.
Fengmao Power main Products: Diesel Generator, Diesel Engines,
Light towers, Water pump units etc.
Mainly Market: Asia, Africa, South America, North America, Europe,
Oceania etc.
Comany have fully experience of production staffs, test enginers
and project design engineers etc.
Test equipment, Highly level prodcution equipment as base of good
quality generator.
Company have more than 100 sets in stock for delivery any time,
also accept OEM orders, even if 1 sets order.
Near Qingdao/Shanghai Sea port, fast delivery.
Highly quality and good service let fengmao power win more and more
favourable comment from clients.
If wanna know more information about our generators or company,
just feel free to contact us!