Add to Cart
Portable TDLAS Gas Analyzer NH3 H2S HCL HF CO Ppm Range High Accuracy High Resolution
☑ Applications Process control: SCR, incineration &combustion processes.
☑ Emission monitoring : Power generation ,engine development, waste incineration furances.
☑ Chemical engineering: Production control & monitoring leak detection, refrigeration, toxic gases
☑ Others: Environmental comparison and acceptance, emergency detection, instrument calibration, self-examination, laboratory gas detection and analysis of multi-level environmental monitoring stations, third-party testing institutions, fixed pollution sources and gaseous pollutants, coal-fired power plants, gas power plants, cement plants, steel plants,etc.
Instrument Characteristics
This portable laser gas analyzer has the following key features, including:
☑ Full-temperature high-temperature heat extraction method is adopted, which is not limited by on-site working conditions, wide applicability, and simple to use and maintain;
☑ Using TDLAS high-resolution spectroscopy technology, it can be measured without interference from other gases, which can effectively reduce the influence of dust or background gas. This feature has obvious advantages compared with other analytical methods.
☑ Laser optical spectrum analysis has the advantages of fast response and high sensitivity. In practical applications, the resolution can reach 0.1ppm, which can meet the accuracy requirements of industrial instrument gas component detection.
Performance parameter | |||||||||||||
Gas | Range | Resolution | Repeatability | Linearity | Response time | Drift | |||||||
HCL | 0-100 mg/m3 | 0.1 mg/m3 | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
HF | 0-100 mg/m3 | 0.1 mg/m3 | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
NH3 | 0-100 ppm | 0.1 ppm | ≤1%FS | ≤1%FS | ≤15S | ≤2%FS | |||||||
Electrical parameters | |||||||||||||
Warm up time | 60min | Digital output | RS232 | Data storage | Configure USB2.0 interface | ||||||||
Power supply | AC200-240V/ 47-63Hz | power | <0.8kW | ||||||||||
Environmental parameters | |||||||||||||
Sample gas humidity | 0-99% R.H. | Sample gas temperature | ≤600℃ | Sample gas pressure | Atmospheric pressure±5kPa | ||||||||
Storage humidity | 0-99% R.H. | Ambient temperature | -10~55℃ | Environmental pressure | 70kPa-120kPa | ||||||||
Sampling flow | 2-3L/min | Protection level | IP44 | ||||||||||
Mechanical parameters | |||||||||||||
Analyzer dimensions | 210(W)*460(L)*340(H)mm | weight | 18kg | ||||||||||
Box dimensions | 500(W)*600(L)*150(H)mm | weight | 7.5kg | ||||||||||
Sample gas inlet joint specifications | Ø6 Stainless steel ferrule joint | Sample gas outlet connector specifications | Ø6PVDF connector |