Home /Pressure Measuring Instruments /

Dual Channel Sample Gas Cooler Condenser 4NL/Min For CEMS Applications

Dual Channel Sample Gas Cooler Condenser 4NL/Min For CEMS Applications

Brand Name:ESEGAS
Model Number:ESE230
Minimum Order Quantity:1 unit
Delivery Time:1-2 Working days
Name:Sample Gas Cooler Condenser
Condensing method:Fluoride-free compressor
Contact Now

Add to Cart

Verified Supplier
Location: Wuhan China
Address: The 4th floor, No.28, Fozuling Road,East-lake Hi-Tech Development Zone,Wuhan 430000,China
Supplier`s last login times: within 1 hours
Shipping
lt's easy to get a shipping quote! Just click the button below and complete the short form.
Get Shipping Quote
Product Details Company Profile
Product Details

Gas Cooler for gas analysis system Gas cooler dual-channel gas condenser for CEMS applications


A gas cooler, also known as a gas condenser or gas conditioning system, is an important component of a gas analysis system. It is used to cool down the sample gas before it enters the gas analyzer or other downstream measurement devices. The purpose of the gas cooler is to remove excess moisture and reduce the gas temperature to appropriate levels for accurate and reliable analysis.


Here are some key features and functions of a gas cooler in a gas analysis system:


1. Cooling Function: The primary function of a gas cooler is to reduce the temperature of the sample gas. This is important because high gas temperatures can interfere with the accuracy and reliability of the analytical measurements. Cooling the gas helps to stabilize the gas composition and minimize the influence of temperature variations on the analysis results.


2. Moisture Removal: Gas coolers often incorporate a condensation process to remove moisture from the sample gas. Cooling the gas below its dew point causes the water vapor to condense, allowing it to be separated from the gas stream. This is crucial because excessive moisture in the gas can affect the accuracy of certain gas analysis techniques and cause corrosion or damage to the analyzer.


3. Heat Exchange: Gas coolers typically employ a heat exchanger design to transfer heat from the sample gas to a cooling medium, such as air or water. The heat exchanger facilitates efficient cooling while maintaining a consistent flow of the sample gas.


4. Temperature Control: Gas coolers may include temperature control mechanisms to maintain the gas temperature within a specific range. This ensures that the gas entering the gas analyzer is at an optimal temperature for accurate measurements. Temperature control can be achieved through various means, such as adjusting the flow rate of the cooling medium or using thermostatic controls.


5. Compact Design: Gas coolers for gas analysis systems are often designed to be compact and space-efficient, allowing for easy integration into the overall gas analysis setup. They are typically installed near the gas sampling point or as close as possible to the gas analyzer.


When selecting a gas cooler for a gas analysis system, consider factors such as the required cooling capacity, the gas flow rate, the desired temperature range, the availability of cooling media (air or water), and any specific requirements of the gas analyzer or the gas being analyzed. It's recommended to consult with manufacturers or suppliers who specialize in gas analysis equipment to ensure you choose a gas cooler that meets your specific needs and provides optimal performance for your gas analysis system.


ESE230 Gas Cooler(Gas analyzer accessories) is a kind of compressed high efficiency moisture removing, used in gas pretreatment system of gas analysis system. It can protect moisture and corresponding corrosion to the gas analyser and guarantee the lifespan lifespan of gas analysers.


Specifications


ItemsDescriptions
Working ambient temperature550
Inlet gas temperature≤180
Inlet gas dew point≤80(@ 25)
Outlet gas dew point≤4(@ 25)
Condensing control temperatureFactory set at 3.0
Temperature controller fluctuation3.0±1.0(@ 25)
Condensing methodfluoride-free compressor
Gas condensing pipeA+B glass heat exchange pipes, diameter * heightΦ40mm*150mm
Inlet gas pressure≤3bar
Allowed gas differential pressure range≤3mbar(gas flow 2NL/min)
Gas capacity4NL/min
Trouble alarmLow temperature alarm, deviation alarm, power off alarm; alarm status dry contact output, capacity 250Vac/1A
Peristaltic pump5r/min
withstand voltage testing standardAC1500V
Leak current≤3.5mA
Inlet gas connectorOD6mm
Water drainage portOD6mm
Condensing working temperature≤30min
Installation methodWall-mounted plate installation
Power supply220VAC 50Hz
Power supply consumption400W
Cabinet size(W×H×D)310*280*290mm
Cabinet colorRAL7035 grey
Weight18kg
4-20mA outputoptional
China Dual Channel Sample Gas Cooler Condenser 4NL/Min For CEMS Applications supplier

Dual Channel Sample Gas Cooler Condenser 4NL/Min For CEMS Applications

Inquiry Cart 0