Add to Cart
BP93420DII differential pressure transmitter
Introduction of diffrential pressure transmitter:
BP93420DII differential pressure transmitter uses a piezoresistive diffused silicon sensor. When the measured medium's differential pressure acts on the corrugated diaphragms at both ends of the sensor, the output signal from the Wheatstone bridge on the sensor chip exhibits a good linear relationship with the differential pressure, enabling accurate measurement of the differential pressure. It is suitable for various gas and liquid differential pressure measurements in industries such as petroleum, chemical, power, and hydrology for pipeline applications.
Product Features:
1. The transmitter features a stainless steel structural design,
making it compact and easy to install
2. It undergoes strict temperature compensation and aging
screening, ensuring stable and reliable performances
3. The electrical interface can be selected as a plug-in or direct
wiring option.
Applications:
1. Fluid flow measurement: Differential pressure transmitters can
be used to measure the flow of a liquid or gas, calculating the
flow rate by measuring the differential pressure generated by the
fluid in the pipe.
2. Liquid level measurement: The differential pressure transmitter
can be used to measure the liquid level, by measuring the
differential pressure on both sides of the liquid to calculate the
liquid level height.
3. Filter blockage monitoring: Differential pressure transmitters
can be used to monitor the degree of blockage of the filter and
determine whether the filter needs to be cleaned or replaced by
measuring the differential pressure before and after the filter.
4. Gas density measurement: Differential pressure transmitters can
calculate the density of a gas by measuring the differential
pressure produced by the gas at different pressures.
5. Air quality monitoring: Differential pressure transmitters can
be used to monitor the quality of indoor or outdoor air, judging
the freshness and pollution of the air by measuring the difference
pressure between indoor and outdoor.
6. HVAC system control: Differential pressure transmitters can be
used to monitor and control parameters such as air flow, wind speed
and wind pressure in HVAC systems.
7. Differential pressure monitoring: Differential pressure
transmitters can be used to monitor pressure differences in
pipelines or containers to ensure proper system operation and fault
diagnosis
Performance Parameters | |
Measurement Range | 0-10KPa...~2MPa |
Pressure Type | Differential Pressure |
Single-side Overload | ≤3 times of the rated range |
Static pressure | The minimum value between 5 times the rated range or 7 MPa |
Accuracy @ 25ºC | ±0.25% (Typical) ±0.5% (Maximum) |
Repeatability | ±0.03% (Typ.) ±0.05%FS (Max.) |
Hysteresis | ±0.03% (Typ.) ±0.05%FS (Max.) |
Long-Term Stability | ±0.5%F.S/Year(≤200KPa) ±0.2%F.S/Year(>200KPa) |
Zero Temperature Drift | ±0.01%FS/ºC(>100KPa), ±0.02%FS/ºC (≤100Kpa) |
Span Temperature Drift | ±0.01%FS/ºC(>100KPa), ±0.02%FS/ºC (≤100Kpa) |
Compensation Temperature | 0-50ºC(0-10KPa, 0-20KPa) ,0-70ºC ,-10-70ºC |
Operating Temperature | -30ºC~80ºC |
Storage Temperature | -40ºC~100ºC |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | 304,316L |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Explosion-proof Rating | Intrinsically safe and explosion-proof |
Protection Rating | IP65 |
Weight | ~0.45kg |
Output Signal | Supply Voltage | Output Type |
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA | 3 wire | |
0/1~5V | ||
0.5~4.5V | 5VDC |
Ordering tips: |
Order Guide | ||||||||
BP93420XX | Pressure Transmitter | |||||||
Code | Outline Construction | |||||||
DII | Differential Pressure Transmitter | |||||||
Measurement Range | 0-10KPa...~2MPa | |||||||
Code | Power Supply | |||||||
D1 | 24VDC | |||||||
D2 | 5VDC | |||||||
D3 | Other | |||||||
Code | Output Signal | |||||||
S1 | 4~20mADC | S5 | 0~20mADC | |||||
S2 | 1~5VDC | S6 | 0~10VDC | |||||
S3 | 0~5VDC | S7 | 0.5~4.5VDC | |||||
S4 | 0~10mADC | |||||||
Code | Pressure Connection | |||||||
J1 | M20×1.5 Male | |||||||
J2 | G1/2 Male | |||||||
J3 | G1/4 Male | |||||||
J4 | 1/2 NPT Male | |||||||
J5 | Other | |||||||
Code | Electrical Connection | |||||||
B1 | Hirschmann | |||||||
B2 | PG7 Plug | |||||||
B3 | Sealed Cable Output | |||||||
B4 | Other | |||||||
Code | Pressure Type | |||||||
D | Differential Pressure |
Q&A |
1. Q: What are the features of your pressure sensor transmitters?
A: High precision, durability, and excellent performance.
Customization available.
2. Q: Can I customize special specifications?
A: Yes, our engineers can tailor products to meet specific needs. We provide OEM and ODM service
3. Q: What is your production capacity?
A: Our manufacturing facilities can produce up to 30,000 pressure
sensor transmitters per month, so we are fully capable of meeting
the needs of large-scale orders. However, it is advisable to
contact our sales team in advance to ensure smooth production and
delivery scheduling.
4. Q: What's the typical delivery period?
A: 5~8 working day for standard models. Customized products may
vary.
5. Q: How are the products priced? Any discounts?
A: Competitive pricing with discounts for bulk orders or long-term
partners.
6. Q: What is the warranty of your products? And after-sales
service?
A: Our warranty time is 24 months after shipment, and our
after-sales will respond with your questions in 24hrs, remote
instruction by PC network is always available.