Add to Cart
BH93420-3051A Water level Transmitter
Introduction of water level transmitter measurement:
BH93420-3051A water level transmitter have a compact structure,
simple adjustment and flexible installation provide convenience for
users to use easily. 4~20mA, 0~5v, 0~10mA and other standard signal
output modes can be selected by the user according to the needs.
Using the principle of hydrostatics to measure liquid level is an
important application of pressure sensors. The special cable with a
vent tube in the middle and special sealing technology ensure the
watertightness of the sensor, and make the reference pressure
chamber communicate with the environmental pressure, so as to
ensure the high precision and high stability of the measurement.
Performance Parameters of water level transmitter measurement | |
---|---|
Measurement Range | 0~10m…400mH2O |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Overload | ≤ 2X rated range |
Accuracy @ 25ºC | ±0.25% (Typ.) ±0.5% (Max.) |
Repeatability | ±0.03% (Typ.) ±0.05%FS (Max.) |
Hysteresis | ±0.03% (Typ.) ±0.05%FS (Max.) |
Long-Term Stability | ±0.15%F.S/year (Max.) |
Zero Temperature Drift | ±0.01%FS/ºC(>100KPa), ±0.02%FS/ºC (≤100Kpa) |
Span Temperature Drift | ±0.01%FS/ºC(>100KPa), ±0.02%FS/ºC (≤100Kpa) |
Compensation Temperature | 0-50ºC (0-1m . 0-2m); 0-70ºC |
Operating Temperature | -20~80ºC |
Storage Temperature | -30~100ºC |
Vibration | 10g,55Hz ~ 2kHz |
Shock | 100g |
Housing Material | Cast aluminum, l1Cr18Ni9Ti |
Diaphragm Material | 316L Stainless Steel |
Insulation Resistance | >=100MΩ@100VDC |
Explosion-proof Rating | ExiaIICT6 |
Protection Rating | IP68 |
O-Ring Seal | Fluoro rubber |
Weight | ~1.5Kg (without cable) |
Cable Material | Polyethylene, Polyurethane, PTFE cable |
Output Signal | Supply Voltage | Output Type |
4~20mA | 15~30VDC | 2/3/4 wire |
RS485 Communication Protocol | 4 wire |
Outline Construction |
Electrical Connection |
Selection Examples |
Ordering tips |
Order Guide | ||||||||||
BH93420 | Code | Outline Construction | ||||||||
III | Liquid level transmitter with the 2088 housing | |||||||||
Measurement Range | 0~10m…400mH2O | |||||||||
Code | Power Supply | |||||||||
D1 | 24VDC | |||||||||
Code | Output Signal | |||||||||
S1 | 4~20mADC | S2 | RS485 | |||||||
Code | Electrical Connection | |||||||||
B5 | 2088 with display | |||||||||
B6 | 3051A | |||||||||
Code | Pressure Type | |||||||||
G | Gauge Pressure | |||||||||
A | Absolute Pressure | |||||||||
S | Sealed Reference Pressure | |||||||||
Code | Material | |||||||||
01 | 304 Stainless Steel | |||||||||
02 | 316L Stainless Steel | |||||||||
Code | Cable Material | |||||||||
C1 | PE | |||||||||
C2 | PU | |||||||||
C3 | PTFE |
FAQ:
1. Q: What are the features of your pressure sensor transmitters?
A: High precision, durability, and excellent performance.
Customization available.
2. Q: Can I customize special specifications?
A: Yes, our engineers can tailor products to meet specific needs. We provide OEM and ODM service.
3. Q: What is your production capacity?
A: Our manufacturing facilities can produce up to 30,000 pressure
sensor transmitters per month, so we are fully capable of meeting
the needs of large-scale orders. However, it is advisable to
contact our sales team in advance to ensure smooth production and
delivery scheduling.
4. Q: What's the typical delivery period?
A: 5~8 working day for standard models. Customized products may
vary.
5. Q: How are the products priced? Any discounts?
A: Competitive pricing with discounts for bulk orders or long-term
partners.
6. Q: What is the warranty of your products? And after-sales
service?
A: Our warranty time is 24 months after shipment, and our
after-sales will respond with your questions in 24hrs, remote
instruction by PC network is always available.