Add to Cart
BPHT24 Pressure Transmitter
Introduction of Pressure Transmitter Sensor:
BPHT24 pressure transmitter utilizes the HT series flat diaphragm
silicon pressure-resistance isolation oil-filled core as the signal
measuring element. The signal processing circuit is located inside
a stainless steel housing, converting the sensor signal into a
standard output signal. This pressure transmitter is primarily used
in places where high sanitary conditions are required, ensuring
reliable and
accurate pressure measurements in hygienic environments
Product Features of Pressure Transmitter Sensor:
Perfomance Parameters:
Measurement Range | 0~35Kpa…~20MPa |
Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
Overload | ≤ 1.5 times of the rated range |
Accuracy @ 25℃ | ±0.25% (Typical) ±0.5% (Maximum) |
Repeatability& Hysteresis | 0.02%F.S(Typ.) 0.05%F.S(Max.) |
Long-Term Stability | ±0.1%F.S/Year(Typ.) ±0.2%F.S/Year(Max.) |
Zero Point Temperature Drift | ±0.02%F.S/℃(≤100KPa) ±0.01%F.S/℃(>100KPa) |
Full Scale Temperature Drift | ±0.02%F.S/℃(≤100KPa) ±0.01%F.S/℃(>100KPa) |
Frequency Response | 2.4Khz |
Compensation Temperature | 0-70℃(≤10mpa,customizable) |
Operating Temperature | -20℃~80℃ |
Storage Temperature | -40℃~120℃ |
Vibration | 10g,55Hz ~ 2kHz |
Housing Material | 304,316L |
Diaphragm Material | 316L |
Insulation Resistance | 100MΩ 100VDC |
Explosion-proof Rating | Ex db IIC T6 Gb |
Protection Rating | IP65 |
O-Ring Seal | Fluoro rubber |
Weight | ~0.15kg |
Output Signal | Supply Voltage | Output Type |
4~20mA | 12~30VDC | 2/3/4 wire |
0~10/20mA | 3 wire | |
0/1~5V | ||
0/1~10V | ||
0.5~4.5V | 5VDC | |
RS485 Communication Protocol | 3.6~30V / Battery | 4 wire |
Selection Examples:
Ordering tips:
1. Choosing the right installation location is very important. Try to avoid installation in an environment with vibration, shock or high temperature, so as not to affect the accuracy of measurement and the life of the equipment.
2. Avoid pressure exceeding the rated range of the pressure transmitter to avoid damage to the equipment. If it is necessary to measure pressure beyond the rated range, the pressure transmitter with the appropriate rated range should be selected.
3. Select the appropriate material according to the characteristics of the measured medium to prevent the medium from corroding the pressure transmitter. If the medium is corrosive, the pressure transmitter of a corrosion-resistant material should be selected.
4. Select the appropriate protection level according to the actual needs. If the equipment will be exposed to wet, dusty or other harsh environments, choose a pressure transmitter with a higher level of protection
Order Guide | ||||||||
BPHT24 | Pressure Transmitter | |||||||
Code | Outline Construction | |||||||
IX | Display Pressure Transmitter | IIC/III | Industrial General/ Display Pressure Transmitter | |||||
Measurement Range | 0~35Kpa…~35MPa | |||||||
(0-X)Kpa or MPa | X: Indicates the Actual Measuring Range | |||||||
Code | Power Supply | |||||||
D1 | 24VDC | |||||||
D2 | 5VDC | |||||||
D3 | Other | |||||||
Code | Output Signal | |||||||
S1 | 4~20mADC | S5 | 0~20mADC | |||||
S2 | 1~5VDC | S6 | 0~10VDC | |||||
S3 | 0~5VDC | S7 | 0.5~4.5VDC | |||||
S4 | 0~10mADC | |||||||
Code | Pressure Connection | |||||||
J1 | M20×1.5 | |||||||
J2 | G1/2 | |||||||
J3 | 1/2NPT | |||||||
Code | Electrical Connection | |||||||
B1 | Hirschmann | |||||||
B2 | PG7 Plug | |||||||
B3 | Sealed Cable Output | |||||||
B4 | 2088 Industrial Casing | |||||||
B5 | 2088 Industrial Casing with Display | |||||||
B6 | Other | |||||||
Code | Pressure Type | |||||||
G | Gauge Pressure | |||||||
A | Absolute Pressure | |||||||
S | Sealed Reference Pressure |
FQA: