Product Details

Axial Lead Glass Discharge Tube SCB-141N Vs 140(119~221)V 1.0pF @8/20μS 1000A Suitable for Power Supplies


DATASHEET: SCB_v2204.1.pdf


Part Number

DC Spark-over

Voltage

Vs(V)

Minimum

Insulation

Resistance

IR(OHM)/DC

Maximum

Capacitance

1KHZ-6Vmax

C (pF)

Surge Current

Capacity

8/20 μS

Surge Life Test
SCB-141N140(126~210)100M / 50V1.01000A10KV / 150A , >200T
SCB-181N180(126~234)100M / 50V1.01000A10KV / 150A , >200T
SCB-201M200(160~240)100M /100V1.01000A10KV / 150A , >200T
SCB-301M300(240~360)100M /100V1.01000A10KV / 150A , >200T
SCB-401M400(320~480)100M / 250V1.01000A10KV / 150A , >200T
SCB-501M500(400~600)100M / 250V1.01000A10KV / 150A , >200T
SCB-601M600(480~720)100M / 250V1.01000A10KV / 150A , >200T
SCB-701M700(560~840)100M / 250V1.01000A10KV / 150A , >200T
SCB-102M1000(800~1200)100M / 500V1.01000A10KV / 150A , >200T
SCB-122M1200(960~1440)100M / 500V1.01000A10KV / 150A , >200T
SCB-152M1500(1200~1800)100M / 500V1.01000A10KV / 150A , >200T


Features:

u Approximately zero leaking current before clamping voltage

u Less decay at on/off state.

u High capability to withstand repeated lightning strikes.

u Low electrode capacitance (≤1.0pF) and high isolation (≥100MΩ).

u RoHS compliant.

u Bilateral symmetrical.

u Temperature, humidity and lightness insensitive.

u Working temperature: -45℃~ +125 ℃

u Storage temperature: -45℃~ +125℃

u Meets MSL level 1, per J-STD-020



Applications:

u Power Supplies

u Motor sparks eliminating

u Relay switching spark absorbing

u Data line pulse guarding

u Electronic devices requiring UL497A and UL497B compliant

u Telephone/Fax/Modem

u High frequency signal transmitters/receivers

u Satellite antenna

u Radio amplifiers

u Alarm systems

u Cathode ray tubes in Monitors/TVs


Part NumberColor Code1Color Code2Color Code3
SCB-141NBlackYellow-
SCB-181NGray--
SCB-201MRed--
SCB-301MOrange--
SCB-401MYellow--
SCB-501MGreen--
SCB-601MBlue--
SCB-701MPurple--
SCB-102MBlack--
SCB-122MBlackRedRed
SCB-152MBlackGreenRed

ItemsTest MethodStandard
DC Spark-over VoltageMeasure starting discharge voltage (Vs) by gradually increasing applied DC voltage. Test current is 0.5mA max. And the DC voltage ascends up within 100V/s(Vs<1000V) or 500V/s(Vs≥1000V).

Rate-of-change, within±30%

insulation resistance & capacitance,

conformed to rated spec.

Insulation ResistanceMeasure the insulation resistance across the terminal at regular voltage. But the test voltage doesn’t over the DC spark-over voltage.
CapacitanceMeasure the electrostatic capacitance by applying a voltage of less than 6V (at 1KHz) between terminals.
Static Life10KV with 1500pf condenser is discharged through 2KΩ resistor. 200 times at an interval of 10sec.

∣△Vs/Vs∣≤30%

Characteristics of other items must meet the specified value

Surge Current

Capacity

1.2/50μs & 8/20μs, 1000A, electrically connected with a resistor (1~2 Ω), ±5 times, each time interval 60 seconds. Thereafter, outer appearance shall be visually examined.No crack and no failures
Cold ResistanceMeasurement after -40℃/1000 HRS & normal temperature/2 HRS.Features are conformed to rated spec
Heat ResistanceMeasurement after 125℃ /1000 HRS & normal temperature/2 HRS.
Humidity ResistanceMeasurement after humidity 90~95℃(45℃ ) /1000 HRS & normal temperature/2 HRS.
Temperature Cycle10 times repetition of cycle -40℃ /30min →normal, temp/2 min →125℃/30min, measurement after normal temp/2 HRS.
Solder AbilityApply flux and immerse in molten solder 230±5℃ for 3sec up to the point of 1.5mm from body. Check for solder adhesion.Lead wire is evenly covered by solder
Solder HeatMeasurement after lead wire is dipped up to the point of 1.5mm from body into 260±5℃ solder for 10secConformed to rated spec
Pull StrengthApply 0.5kg load for 10secLead shall not pull out to snap
Flexural StrengthBend lead wire at the point of 2mm from body under 0.25 load and back to its original point. Repeat 1 time.

DC Spark-over VoltageMeasure starting discharge voltage (Vs) by gradually increasing applied DC voltage. Test current is 0.5mA max. And the DC voltage ascends up within 100V/s(Vs<1000V) or 500V/s(Vs≥1000V).

Rate-of-change, within±30%

insulation resistance & capacitance,

conformed to rated spec.

Insulation ResistanceMeasure the insulation resistance across the terminal at regular voltage. But the test voltage doesn’t over the DC spark-over voltage.
CapacitanceMeasure the electrostatic capacitance by applying a voltage of less than 6V (at 1KHz) between terminals.
Static Life10KV with 1500pf condenser is discharged through 2KΩ resistor. 200 times at an interval of 10sec.

∣△Vs/Vs∣≤30%

Characteristics of other items must meet the specified value

Surge Current

Capacity

1.2/50μs & 8/20μs, 1000A, electrically connected with a resistor (1~2 Ω), ±5 times, each time interval 60 seconds. Thereafter, outer appearance shall be visually examined.No crack and no failures
Cold ResistanceMeasurement after -40℃/1000 HRS & normal temperature/2 HRS.Features are conformed to rated spec
Heat ResistanceMeasurement after 125℃ /1000 HRS & normal temperature/2 HRS.
Humidity ResistanceMeasurement after humidity 90~95℃(45℃ ) /1000 HRS & normal temperature/2 HRS.
Temperature Cycle10 times repetition of cycle -40℃ /30min →normal, temp/2 min →125℃/30min, measurement after normal temp/2 HRS.
Solder AbilityApply flux and immerse in molten solder 230±5℃ for 3sec up to the point of 1.5mm from body. Check for solder adhesion.Lead wire is evenly covered by solder
Solder HeatMeasurement after lead wire is dipped up to the point of 1.5mm from body into 260±5℃ solder for 10secConformed to rated spec
Pull StrengthApply 0.5kg load for 10secLead shall not pull out to snap
Flexural StrengthBend lead wire at the point of 2mm from body under 0.25 load and back to its original point. Repeat 1 time.