Add to Cart
Axial Lead Glass Discharge Tube SCB-141N Vs 140(119~221)V 1.0pF @8/20μS 1000A Suitable for Power Supplies
DATASHEET: SCB_v2204.1.pdf
Part Number | DC Spark-over Voltage Vs(V) | Minimum Insulation Resistance IR(OHM)/DC | Maximum Capacitance 1KHZ-6Vmax C (pF) | Surge Current Capacity 8/20 μS | Surge Life Test |
SCB-141N | 140(126~210) | 100M / 50V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-181N | 180(126~234) | 100M / 50V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-201M | 200(160~240) | 100M /100V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-301M | 300(240~360) | 100M /100V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-401M | 400(320~480) | 100M / 250V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-501M | 500(400~600) | 100M / 250V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-601M | 600(480~720) | 100M / 250V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-701M | 700(560~840) | 100M / 250V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-102M | 1000(800~1200) | 100M / 500V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-122M | 1200(960~1440) | 100M / 500V | 1.0 | 1000A | 10KV / 150A , >200T |
SCB-152M | 1500(1200~1800) | 100M / 500V | 1.0 | 1000A | 10KV / 150A , >200T |
Features:
u Approximately zero leaking current before clamping voltage u Less decay at on/off state. u High capability to withstand repeated lightning strikes. u Low electrode capacitance (≤1.0pF) and high isolation (≥100MΩ). u RoHS compliant. u Bilateral symmetrical. u Temperature, humidity and lightness insensitive. u Working temperature: -45℃~ +125 ℃ u Storage temperature: -45℃~ +125℃ u Meets MSL level 1, per J-STD-020 |
Applications:
u Power Supplies u Motor sparks eliminating u Relay switching spark absorbing u Data line pulse guarding u Electronic devices requiring UL497A and UL497B compliant u Telephone/Fax/Modem u High frequency signal transmitters/receivers u Satellite antenna u Radio amplifiers u Alarm systems u Cathode ray tubes in Monitors/TVs |
Part Number | Color Code1 | Color Code2 | Color Code3 |
SCB-141N | Black | Yellow | - |
SCB-181N | Gray | - | - |
SCB-201M | Red | - | - |
SCB-301M | Orange | - | - |
SCB-401M | Yellow | - | - |
SCB-501M | Green | - | - |
SCB-601M | Blue | - | - |
SCB-701M | Purple | - | - |
SCB-102M | Black | - | - |
SCB-122M | Black | Red | Red |
SCB-152M | Black | Green | Red |
Items | Test Method | Standard |
DC Spark-over Voltage | Measure starting discharge voltage (Vs) by gradually increasing applied DC voltage. Test current is 0.5mA max. And the DC voltage ascends up within 100V/s(Vs<1000V) or 500V/s(Vs≥1000V). | Rate-of-change, within±30% insulation resistance & capacitance, conformed to rated spec. |
Insulation Resistance | Measure the insulation resistance across the terminal at regular voltage. But the test voltage doesn’t over the DC spark-over voltage. | |
Capacitance | Measure the electrostatic capacitance by applying a voltage of less than 6V (at 1KHz) between terminals. | |
Static Life | 10KV with 1500pf condenser is discharged through 2KΩ resistor. 200 times at an interval of 10sec. | ∣△Vs/Vs∣≤30% Characteristics of other items must meet the specified value |
Surge Current Capacity | 1.2/50μs & 8/20μs, 1000A, electrically connected with a resistor (1~2 Ω), ±5 times, each time interval 60 seconds. Thereafter, outer appearance shall be visually examined. | No crack and no failures |
Cold Resistance | Measurement after -40℃/1000 HRS & normal temperature/2 HRS. | Features are conformed to rated spec |
Heat Resistance | Measurement after 125℃ /1000 HRS & normal temperature/2 HRS. | |
Humidity Resistance | Measurement after humidity 90~95℃(45℃ ) /1000 HRS & normal temperature/2 HRS. | |
Temperature Cycle | 10 times repetition of cycle -40℃ /30min →normal, temp/2 min →125℃/30min, measurement after normal temp/2 HRS. | |
Solder Ability | Apply flux and immerse in molten solder 230±5℃ for 3sec up to the point of 1.5mm from body. Check for solder adhesion. | Lead wire is evenly covered by solder |
Solder Heat | Measurement after lead wire is dipped up to the point of 1.5mm from body into 260±5℃ solder for 10sec | Conformed to rated spec |
Pull Strength | Apply 0.5kg load for 10sec | Lead shall not pull out to snap |
Flexural Strength | Bend lead wire at the point of 2mm from body under 0.25 load and back to its original point. Repeat 1 time. |
DC Spark-over Voltage | Measure starting discharge voltage (Vs) by gradually increasing applied DC voltage. Test current is 0.5mA max. And the DC voltage ascends up within 100V/s(Vs<1000V) or 500V/s(Vs≥1000V). | Rate-of-change, within±30% insulation resistance & capacitance, conformed to rated spec. |
Insulation Resistance | Measure the insulation resistance across the terminal at regular voltage. But the test voltage doesn’t over the DC spark-over voltage. | |
Capacitance | Measure the electrostatic capacitance by applying a voltage of less than 6V (at 1KHz) between terminals. | |
Static Life | 10KV with 1500pf condenser is discharged through 2KΩ resistor. 200 times at an interval of 10sec. | ∣△Vs/Vs∣≤30% Characteristics of other items must meet the specified value |
Surge Current Capacity | 1.2/50μs & 8/20μs, 1000A, electrically connected with a resistor (1~2 Ω), ±5 times, each time interval 60 seconds. Thereafter, outer appearance shall be visually examined. | No crack and no failures |
Cold Resistance | Measurement after -40℃/1000 HRS & normal temperature/2 HRS. | Features are conformed to rated spec |
Heat Resistance | Measurement after 125℃ /1000 HRS & normal temperature/2 HRS. | |
Humidity Resistance | Measurement after humidity 90~95℃(45℃ ) /1000 HRS & normal temperature/2 HRS. | |
Temperature Cycle | 10 times repetition of cycle -40℃ /30min →normal, temp/2 min →125℃/30min, measurement after normal temp/2 HRS. | |
Solder Ability | Apply flux and immerse in molten solder 230±5℃ for 3sec up to the point of 1.5mm from body. Check for solder adhesion. | Lead wire is evenly covered by solder |
Solder Heat | Measurement after lead wire is dipped up to the point of 1.5mm from body into 260±5℃ solder for 10sec | Conformed to rated spec |
Pull Strength | Apply 0.5kg load for 10sec | Lead shall not pull out to snap |
Flexural Strength | Bend lead wire at the point of 2mm from body under 0.25 load and back to its original point. Repeat 1 time. |