Add to Cart
30KPA45C TVs Diode 30000W R6 P600 package High Voltage
DATASHEET: 30KPA.pdf
Description:
The 30KPA series is designed specifically to protect sensitive electronic equipment from voltage transients induced by lightning and other transient voltage events.
Transient Suppression Diode TVS Selection methods
1.To know the customer's product, operating voltage, application port, protection level.
2.VRWM (operating voltage) value of the device ≥ normal operation in the customer's circuit
3.VC (clamp voltage) value < maximum voltage for the back-end chip
4.Select the package and power of the device according to the application port and protection level.
Part Number | Reverse Stand-Off Voltage VRWM (V) | Breakdown Voltage VBR (V) @IT | Test Current IT (mA) | Maximum Clamping Voltage VC @IPP (V) | Maximum Peak Pulse Current IPP (A) | Maximum Reverse Leakage IR @VRWM (μA) | |
Uni | Bi | MIN | |||||
30KPA28A | 30KPA28CA | 28 | 31.28 | 50 | 50.0 | 606.0 | 5000 |
30KPA30A | 30KPA30CA | 30 | 33.51 | 50 | 55.2 | 548.9 | 5000 |
30KPA33A | 30KPA33CA | 33 | 36.90 | 50 | 58.5 | 517.9 | 5000 |
30KPA36A | 30KPA36CA | 36 | 40.20 | 50 | 61.8 | 490.3 | 5000 |
30KPA39A | 30KPA39CA | 39 | 43.60 | 20 | 67.2 | 450.9 | 2000 |
30KPA42A | 30KPA42CA | 42 | 46.90 | 10 | 72.0 | 420.8 | 1000 |
30KPA43A | 30KPA43CA | 43 | 48.00 | 10 | 73.0 | 415.1 | 1000 |
30KPA45A | 30KPA45CA | 45 | 50.30 | 5 | 77.4 | 391.5 | 250 |
30KPA48A | 30KPA48CA | 48 | 53.60 | 5 | 81.6 | 371.3 | 150 |
30KPA51A | 30KPA51CA | 51 | 57.00 | 5 | 86.4 | 350.7 | 50 |
30KPA54A | 30KPA54CA | 54 | 60.30 | 5 | 91.4 | 331.5 | 20 |
30KPA58A | 30KPA58CA | 58 | 64.80 | 5 | 92.4 | 327.9 | 20 |
30KPA60A | 30KPA60CA | 60 | 67.00 | 5 | 102.0 | 297.1 | 15 |
30KPA64A | 30KPA64CA | 64 | 71.50 | 5 | 104.0 | 291.3 | 10 |
30KPA66A | 30KPA66CA | 66 | 73.70 | 5 | 107.0 | 283.2 | 2 |
30KPA70A | 30KPA70CA | 70 | 78.20 | 5 | 109.0 | 278.0 | 2 |
30KPA71A | 30KPA71CA | 71 | 79.30 | 5 | 111.5 | 271.7 | 2 |
30KPA72A | 30KPA72CA | 72 | 80.40 | 5 | 114.0 | 265.8 | 2 |
30KPA75A | 30KPA75CA | 75 | 83.80 | 5 | 119.4 | 253.8 | 2 |
30KPA78A | 30KPA78CA | 78 | 87.10 | 5 | 129.0 | 234.9 | 2 |
30KPA84A | 30KPA84CA | 84 | 93.80 | 5 | 139.2 | 217.7 | 2 |
30KPA90A | 30KPA90CA | 90 | 100.50 | 5 | 146.4 | 207.0 | 2 |
30KPA96A | 30KPA96CA | 96 | 107.20 | 5 | 156.0 | 194.2 | 2 |
30KPA102A | 30KPA102CA | 102 | 113.90 | 5 | 165.6 | 183.0 | 2 |
30KPA108A | 30KPA108CA | 108 | 120.60 | 5 | 175.2 | 172.9 | 2 |
30KPA120A | 30KPA120CA | 120 | 134.00 | 5 | 194.4 | 155.9 | 2 |
30KPA132A | 30KPA132CA | 132 | 147.40 | 5 | 213.0 | 142.3 | 2 |
30KPA144A | 30KPA144CA | 144 | 160.80 | 5 | 223.2 | 135.8 | 2 |
30KPA150A | 30KPA150CA | 150 | 167.60 | 5 | 233.4 | 129.8 | 2 |
30KPA156A | 30KPA156CA | 156 | 174.30 | 5 | 245.0 | 123.7 | 2 |
30KPA160A | 30KPA160CA | 160 | 178.70 | 5 | 252.6 | 120.0 | 2 |
30KPA168A | 30KPA168CA | 168 | 187.70 | 5 | 272.4 | 111.2 | 2 |
30KPA170A | 30KPA170CA | 170 | 189.90 | 5 | 275.0 | 110.2 | 2 |
30KPA180A | 30KPA180CA | 180 | 201.10 | 5 | 290.4 | 104.3 | 2 |
30KPA198A | 30KPA198CA | 198 | 221.20 | 5 | 319.8 | 94.7 | 2 |
30KPA216A | 30KPA216CA | 216 | 241.30 | 5 | 348.6 | 86.9 | 2 |
30KPA240A | 30KPA240CA | 240 | 268.10 | 5 | 387.0 | 78.3 | 2 |
30KPA258A | 30KPA258CA | 258 | 188.20 | 5 | 416.4 | 72.8 | 2 |
30KPA260A | 30KPA260CA | 260 | 290.40 | 5 | 416.0 | 72.8 | 2 |
30KPA270A | 30KPA270CA | 270 | 301.60 | 5 | 436.2 | 69.5 | 2 |
30KPA280A | 30KPA280CA | 280 | 312.80 | 5 | 464.0 | 65.3 | 2 |
30KPA288A | 30KPA288CA | 288 | 321.70 | 5 | 469.9 | 64.5 | 2 |
Applications:
Small power supply protection, Switches, POS machines, Lightning arresters, Building intercoms, Monitoring systems, Parking cards, Transmission systems, Instruments, meters, Communication products, Control panels, GPS navigators
Parameter | Symbol | Value | Unit |
Peak Pulse Power Dissipation with a 10/1000µs waveform (Fig.1)(Note 1), (Note 2) | PPPM | 30000 | Watts |
Peak Pulse Current with a 10/1000µs waveform.(Note1,Fig.3) | IPP | See Next Table | Amps |
Power Dissipation on Infinite Heat Sink at TL=75°C | PM(AV) | 8.0 | Watt |
Peak Forward Surge Current, 8.3ms Single Half Sine Wave (Note 3) | IFSM | 500 | Amps |
Operating junction and Storage Temperature Range. | TJ , TSTG | -55 to +150 | °C |
Notes: 1. Non-repetitive current pulse, per Fig. 3 and derated above TA = 25°C per Fig. 2. 2. Mounted on 5.0mm x 5.0mm (0.03mm thick) Copper Pads to each terminal. 3. 8.3ms single half sine-wave, or equivalent square wave, Duty cycle = 4 pulses per minutes maximum. 4. VF < 3.5V for VBR < 200V and VF< 6.5V for VBR > 201V. |