Add to Cart
350V Axial Leaded GDT SC2E5-350LL, Low Insertion Loss Gas Discharge
Tube
DATASHEET: SC2E5_v91.1.pdf
Part Number | Marking | DC Spark-over Voltage | Maximum Impulse Spark-over Voltage | Minimum Insulation Resistance | Maximum Capacitance | Arc Voltage | Service Life | ||||
Nominal Impulse Discharge Current | Max Impulse Discharge Current | Nominal Alternating Discharge Current | Impulse Life | ||||||||
@100V/S | @100V/μs | @1KV/μs | @1MHz | @1A | @8/20μs ±5 times | @8/20μs 1 time | @50Hz 1 Sec 10 times | @10/1000μs 300 times | |||
SC2E5-75LL SC2E5-75L | SOCAY75L | 75V±20% | <500V | <600V | 1 GΩ (at 25V) | <1.0pF | ~15V | 5KA | 10KA | 5A | 100A |
SC2E5-90LL SC2E5-90L | SOCAY90L | 90V±20% | <500V | <600V | 1 GΩ (at 50V) | <1.0pF | ~15V | 5KA | 10KA | 5A | 100A |
SC2E5-150LL SC2E5-150L | SOCAY150L | 150V±20% | <500V | <600V | 1 GΩ (at 50V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-230LL SC2E5-230L | SOCAY230L | 230V±20% | <600V | <700V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-250LL SC2E5-250L | SOCAY250L | 250V±20% | <700V | <800V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-300LL SC2E5-300L | SOCAY300L | 300V±20% | <800V | <900V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-350LL SC2E5-350L | SOCAY350L | 350V±20% | <800V | <900V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-420LL SC2E5-420L | SOCAY420L | 420V±20% | <900V | <1000V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-470LL SC2E5-470L | SOCAY470L | 470V±20% | <900V | <1000V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-600LL SC2E5-600L | SOCAY600L | 600V±20% | <1100V | <1200V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
SC2E5-800LL SC2E5-800L | SOCAY800L | 800V±20% | <1200V | <1400V | 1 GΩ (at 100V) | <1.0pF | ~20V | 5KA | 10KA | 5A | 100A |
Notes: 1). Terms in accordance with ITU-T K.12 and GB/T 9043-2008 2). At delivery AQL 0.65 level Ⅱ, DIN ISO 2859 |
Materials | Nickel-plated with Tinplated wires | |
Product Marking | SOCAY XXXL XXX -Nominal voltage L -5KA | |
Glow to Arc Transition Current | < 0.5 Amps | |
Glow Voltage | ~60 Volts | |
Storage and Operational Temperature | -40 to +90°C | |
Climatic category (IEC 60068-1) | 40/90/21 | |
Weight | SC2E5-XXXLL | ~1.0g |
SC2E5-XXXL | ~0.85g |