Product Description/Features:
Solenoid valve selection should first follow the four major
principles of safety, reliability, applicability and economy,
followed by the selection of six field conditions (namely pipeline
parameters, fluid parameters, pressure parameters, electrical
parameters, mode of action, and special requirements).
Selection basis:
1, according to the pipeline parameters to select the solenoid
valve: diameter specifications (i.e. DN), interface mode
1) Determine the diameter (DN) size according to the internal
diameter size or flow requirements of the pipeline on site;
2) Interface mode, general > DN50 to choose the flange
interface, ≤DN50 can be freely selected according to user needs.
2, according to the fluid parameters to select the solenoid valve:
material, temperature group
1) Corrosive fluids: corrosion-resistant solenoid valves and all
stainless steel should be selected; Food ultra-clean fluid: food
grade stainless steel solenoid valve should be selected;
2) High temperature fluid: to choose the solenoid valve made of
high temperature resistant electrical materials and sealing
materials, and to choose the type of piston structure;
3) Fluid state: large to gaseous, liquid or mixed state, especially
when the caliber is greater than DN25 must be distinguished;
4) Fluid viscosity: usually below 50cSt can be arbitrarily
selected, if more than this value, you should choose a
high-viscosity solenoid valve.
3, according to the pressure parameters to select the solenoid
valve: principle and structural varieties
1) Nominal pressure: This parameter has the same meaning as other
general valves, and is determined according to the nominal pressure
of the pipeline;
2) Working pressure: If the working pressure is low, direct action
or step by step principle must be selected; When the minimum
working pressure difference is above 0.04Mpa, direct acting type,
step by step, pilot type can be selected.
4, electrical selection: voltage specifications should be preferred
AC220V, DC24 is more convenient.
5, according to the length of continuous working time to choose:
normally closed, normally open, or sustainable power
1) When the solenoid valve needs to be opened for a long time, and
the duration is longer than the closing time, the normally open
type should be selected;
2) If the opening time is short or the opening and closing time is
not long, choose normally closed type;
3) However, some working conditions for safety protection, such as
furnace and kiln flame monitoring, can not be selected normally
open, should be selected for long-term power type.
6, according to environmental requirements to select auxiliary
functions: explosion-proof, check, manual, waterproof fog, water
shower, diving.
Selection principle
Security:
1, corrosive media: plastic king solenoid valve and stainless steel
should be selected; For the strong corrosion of the medium must be
selected isolation diaphragm type. Neutral medium, it is also
appropriate to choose copper alloy as the valve shell material of
the solenoid valve, otherwise, the valve shell often has rust chips
off, especially in the case of infrequent action. Ammonia valves
can not be made of copper.
2, explosive environment: must choose the corresponding
explosion-proof grade products, open installation or dust occasions
should choose waterproof, dust-proof varieties.
3, the nominal pressure of the solenoid valve should exceed the
highest working pressure in the tube.
Applicability:
1. Medium characteristics
1) Quality gas, liquid or mixed state respectively choose different
varieties of solenoid valve;
2) The medium temperature of different specifications of products,
otherwise the coil will burn, seal aging, seriously affect the
service life;
3) Medium viscosity, usually below 50cSt. If this value is
exceeded, when the diameter is greater than 15mm, use a
multi-function solenoid valve; When the diameter is less than 15mm,
use a high-viscosity solenoid valve.
4) When the cleanliness of the medium is not high, the
recoil-filter valve should be installed before the solenoid valve.
When the pressure is low, the direct-acting diaphragm solenoid
valve can be selected;
5) If the medium is directional circulation, and reverse flow is
not allowed, two-way circulation is required;
6) The medium temperature should be selected within the allowable
range of the solenoid valve.
2. Pipeline parameters
1) Select the valve port and model according to the medium flow
direction requirements and pipeline connection mode;
2) The nominal diameter is selected according to the flow rate and
Kv value of the valve, and the inner diameter of the pipeline can
also be selected;
3) Working pressure difference: the lowest working pressure
difference above 0.04Mpa can be used indirect pilot type; If the
minimum working pressure difference is close to or less than zero,
the direct acting type or step by step type must be selected.
3. Environmental conditions
1) The maximum and minimum temperature of the environment should be
selected within the allowable range;
2) When the relative humidity in the environment is high and there
are water droplets and rain, waterproof solenoid valve should be
selected;
3) Special varieties should be selected for occasions such as
vibration, turbulence and shock in the environment, such as Marine
solenoid valves;
4) Use in corrosive or explosive environments should be
preferentially selected according to safety requirements of
corrosion-resistant type;
5) If the environmental space is limited, it is necessary to choose
a multi-functional solenoid valve, because it eliminates the bypass
and three manual valves and is convenient for online maintenance.
4. Power supply conditions
1) According to the type of power supply, choose AC and DC solenoid
valves respectively. Generally speaking, AC power supply is easy to
access;
2) For voltage specifications, AC220V.DC24V is preferred;
3) Power supply voltage fluctuation usually AC selection +%10%
-15%, DC allowed ±% 10% or so, if out of tolerance, must take
voltage regulation measures;
4) The rated current and power consumption should be selected
according to the power supply capacity. It should be noted that the
VA value is high when AC starting, and the indirect pilot solenoid
valve should be preferred when the capacity is insufficient.
5. Control accuracy
1) Ordinary solenoid valve only open, close two positions, in the
control accuracy requirements of high and stable parameters need to
choose a multi-digit solenoid valve;
2) Operation time: refers to the time when the electrical signal is
connected or cut off to the completion of the main valve action;
3) Leakage: The leakage value given on the sample is a common
economic grade.
Reliability:
1, working life, this is not included in the factory test project,
belongs to the type test project. In order to ensure the quality
should choose regular manufacturers of brand-name products.
2, working system: divided into long-term working system, repeated
short-time working system and short-time working system three. If
the valve is opened for a long time and only closed for a short
time, the normally open solenoid valve should be selected.
3, working frequency: When the operation frequency is high, the
structure should be preferred direct acting solenoid valve, and the
power supply is preferred AC.
4, action reliability
Strictly speaking, this test has not been officially included in
China's solenoid valve professional standards, in order to ensure
the quality of regular manufacturers should choose brand-name
products. In some cases, the number of movements is not much, but
the reliability requirements are very high, such as fire
protection, emergency protection, etc., must not be taken lightly.
It is particularly important to take two simultaneous double
insurance.
Economy:
It is one of the scales chosen, but must be economical on a safe,
applicable and reliable basis.
Economy is not only the price of the product, but also the cost of
its function and quality as well as installation and maintenance
and other accessories.
More importantly, a solenoid valve in the entire automatic control
system in the entire automatic control system and even in the
production line accounted for very little cost, if the greed of
small and cheap wrong selection caused by the damage group is huge.
Name | Solenoid valve |
Brand | Atos |
Model | SDHE-0639-O-WP-10S |
Color | silver +black etc |
Material | cast iron |
Warranty | 6 months |
lead time | 5-8 working days |
Package | Carton packing |
ABOUT COMPANY:
Changsha HuaYi Technology Co., LTD.,
Changsha HuaYi Technology Co., LTD., specialized in the sale of
construction machinery parts.
Our company mainly business in various brands of pump trucks,
excavators, cranes, wet spray machines and other accessories, as
remote controls, Rexroth oil pump, transfer boxes, double pump
pipes, lubrication pump, Harvey/Eaton/Parker/Kawasaki valves.
our company specializes in the offline and online trading of used
construction vehicles in China, so the concrete pump trucks
displayed on the website may have been sold offline.Our database
provides a large number of fresh used concrete pump trucks, used
excavator used mixer trucks and other construction vehicles, please
contact our sales directly to provide you with more accurate
services.Thank you for your patience to browse!