P+F K-LB-1.30G Surge Protection Barrier 8 Terminals For Unprotected Area

Brand Name:P+F
Certification:CE
Model Number:K-LB-1.30G
Minimum Order Quantity:1pc
Delivery Time:on request
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Hong kong China
Address: Unit 1406B 14/F,The Belgian Bank Building, Nos. 721-725 Nathan Road, Mongkok, Kowloon,Hong kong.
Supplier`s last login times: within 39 hours
Product Details Company Profile
Product Details

Surge Protection Barrier K-LB-1.30G


  • 1-channel

  • Mounting on DIN mounting rail

  • For intrinsically safe or non-intrinsically safe 30 V applications

  • Protects field or control circuit inputs

  • Max. surge current (8/20 µs) 20 kA

  • Uninterruptable operation (auto reset)

  • Up to SIL 3 acc. to IEC/EN 61508

General specifications

Number of protected signal lines

2

Topology

grounded

Functional safety related parameters

Safety Integrity Level (SIL)

SIL 3

Electrical specifications

Connection

protected area: terminals 7, 8
unprotected area: terminals 1, 2

Rated current

250 mA

Leakage current

< 10 µA at 24 V and 25 °C (77 °F) , line-line

Nominal voltage

24 V DC

Maximum continuous operating voltage

30 V DC

Series resistance

< 0.5 Ω per line

Impulse rating

10 kV/5 kA (category C2)
2 kV/2 kA (category D1)

Impulse discharge current (10/350 µs)

2 kA per line (2x)

Nominal discharge current (8/20 µs)

5 kA per line (10x)

Rated surge current (8/20 µs)

10 kA per line (1x)

Total discharge current (8/20 µs)

20 kA (1x)

Voltage protection level

max. 100 V line-line for nominal discharge current In
max. 50 V line-earth for nominal discharge current In

Impulse reset time

< 30 ms

Insertion loss

≤ 0.05 dB, at 0 ... 4 kHz, in 600 Ω-System
≤ 3 dB, at 0 ... 174 kHz, in 100 Ω-System

Indicators/settings

Labeling

space for labeling at the front

Conformity

Degree of protection

IEC 60529:2013

Surge protective devices for low voltage

EN 61643-21:2001+A1:2009+A2:2013
IEC 61643-21:2001+A1:2008+A2:2012

Operating conditions

Installation conditions



Mounting location

indoor

Ambient conditions

Ambient temperature

-30 ... 80 °C (-22 ... 176 °F)
For usage in hazardous area observe the EC-type examination certificate.

Relative humidity

5 ... 95 %

Mechanical specifications

Degree of protection

IP20

Connection

screw terminals

Core cross section

2 x 2.5 mm2

Mass

approx. 100 g

Dimensions

12.5 x 115 x 116 mm (0.5 x 4.5 x 4.6 inch) (W x H x D)


Height

115 mm


Width

12.5 mm


Depth

116 mm

Mounting

on 35 mm DIN mounting rail acc. to EN 60715:2001

Data for application in connection with hazardous areas

EU-type examination certificate

PTB 00 ATEX 2176 X


Marking

II 2(1)G Ex ia IIC T6/T5/T4


Temperature class

T6 for ambient temperature ≤ 50 °C
T5 for ambient temperature ≤ 70 °C
T4 for ambient temperature ≤ 80 °C


Voltage

30 V


Current

250 mA


Internal capacitance

negligible


Internal inductance

200 µH

Certificate

PF 16 CERT 4065 X


Marking

II (3)D [Ex ic Dc] IIIC

Directive conformity



Directive 2014/34/EU

EN 60079-0:2012+A11:2013 , EN 60079-11:2012

International approvals

CSA approval



Control drawing

116-0187 (cCSAus)

IECEx approval



IECEx certificate

IECEx BAS 14.0010X


China P+F K-LB-1.30G Surge Protection Barrier 8 Terminals For Unprotected Area supplier

P+F K-LB-1.30G Surge Protection Barrier 8 Terminals For Unprotected Area

Inquiry Cart 0