Add to Cart
1-channel
Mounting on DIN mounting rail
For intrinsically safe or non-intrinsically safe 30 V applications
Protects field or control circuit inputs
Max. surge current (8/20 µs) 20 kA
Uninterruptable operation (auto reset)
Up to SIL 3 acc. to IEC/EN 61508
General specifications | ||
---|---|---|
Number of protected signal lines | 2 | |
Topology | grounded | |
Functional safety related parameters | ||
Safety Integrity Level (SIL) | SIL 3 | |
Electrical specifications | ||
Connection | protected area: terminals 7, 8 | |
Rated current | 250 mA | |
Leakage current | < 10 µA at 24 V and 25 °C (77 °F) , line-line | |
Nominal voltage | 24 V DC | |
Maximum continuous operating voltage | 30 V DC | |
Series resistance | < 0.5 Ω per line | |
Impulse rating | 10 kV/5 kA (category C2) | |
Impulse discharge current (10/350 µs) | 2 kA per line (2x) | |
Nominal discharge current (8/20 µs) | 5 kA per line (10x) | |
Rated surge current (8/20 µs) | 10 kA per line (1x) | |
Total discharge current (8/20 µs) | 20 kA (1x) | |
Voltage protection level | max. 100 V line-line for nominal discharge current In | |
Impulse reset time | < 30 ms | |
Insertion loss | ≤ 0.05 dB, at 0 ... 4 kHz, in 600 Ω-System | |
Indicators/settings | ||
Labeling | space for labeling at the front | |
Conformity | ||
Degree of protection | IEC 60529:2013 | |
Surge protective devices for low voltage | EN 61643-21:2001+A1:2009+A2:2013 | |
Operating conditions | ||
Installation conditions | ||
Mounting location | indoor | |
Ambient conditions | ||
Ambient temperature | -30 ... 80 °C (-22 ... 176 °F) | |
Relative humidity | 5 ... 95 % | |
Mechanical specifications | ||
Degree of protection | IP20 | |
Connection | screw terminals | |
Core cross section | 2 x 2.5 mm2 | |
Mass | approx. 100 g | |
Dimensions | 12.5 x 115 x 116 mm (0.5 x 4.5 x 4.6 inch) (W x H x D) | |
Height | 115 mm | |
Width | 12.5 mm | |
Depth | 116 mm | |
Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | |
Data for application in connection with hazardous areas | ||
EU-type examination certificate | PTB 00 ATEX 2176 X | |
Marking | II 2(1)G Ex ia IIC T6/T5/T4 | |
Temperature class | T6 for ambient temperature ≤ 50 °C | |
Voltage | 30 V | |
Current | 250 mA | |
Internal capacitance | negligible | |
Internal inductance | 200 µH | |
Certificate | PF 16 CERT 4065 X | |
Marking | II (3)D [Ex ic Dc] IIIC | |
Directive conformity | ||
Directive 2014/34/EU | EN 60079-0:2012+A11:2013 , EN 60079-11:2012 | |
International approvals | ||
CSA approval | ||
Control drawing | 116-0187 (cCSAus) | |
IECEx approval | ||
IECEx certificate | IECEx BAS 14.0010X |