Pump Inverter VFD 380v 3phase 2.2kw Variable Speed Drive 3hp Vsd for fan pump

Brand Name:ZONCN
Certification:CE
Model Number:T200
Minimum Order Quantity:1
Delivery Time:within 15 days
Payment Terms:T/T, Paypal
Contact Now

Add to Cart

Verified Supplier
Location: Wuhu Anhui China
Address: BLDG 16, #29 Rongyue Dongfang, Guandou Street, Jiujiang District, Wuhu City, Anhui Province 
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

Pump Inverter VFD 380v 3phase 2.2kw Variable Speed Drive 3hp Vsd for fan pump


ZONCN T200 Inverter Specification

ITEMT200 Inverter
Basic functionMaximum frequency0~600.00Hz
Carrier frequency0.5kHz~16kHz
The carrier frequency can be automatically adjusted based on the load features.
Input frequency resolutionDigital setting:0.01Hz
Analog setting: maximum frequency×0.025%
Control modeVoltage/Frequency control (V/F)
Sensorless flux vector control (No PG)
Closed loop vector control (Have PG)
Startup torqueG Type:0.5Hz/150%(No PG);
P Type:0.5Hz/100%
Speed range1:100(No PG)
Speed stability accuracy±0.5%(No PG)
Torque control accuracy±5%(Have PG)
Overload capacityG type: 60s for 150% of the rated current, 3s for 180% of the rated current.
P type: 60s for 120% of the rated current, 3s for 150% of the rated current
Torque boostFixed boost
Customized boost 0.1%–30.0%
V/F curveStraight-line V/F curve
Multi-point V/F curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power,1.8-power, square)
V/F separationTwo types: complete separation; half separation
Ramp modeStraight-line ramp
S-curve ramp
Four groups of acceleration/deceleration time with the range of 0.0–6500.0s
DC brakingDC braking frequency: 0.00 Hz to maximum frequency
Braking time: 0.0-100.0s
Braking action current value: 0.0%–100.0%
JOG controlJog frequency range:0.00Hz~50.00Hz. JOG acceleration/deceleration time0.0s~6500.0s.
Onboard Multiple preset speedsIt implements up to 16 speeds via the simple PLC function or by input terminal states
Onboard PIDIt realizes process-controlled closed loop control system easily.
Auto voltageIt can keep constant output voltage automatically when the mains voltage changes.
regulation (AVR)
Over-voltage/The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current.
Over-current stall
control
Rapid current limitIt helps to avoid frequent over-current faults of the inverter.
Torque limit and torque controlIt can limit the torque automatically and prevent frequent over-current tripping during the running process.
Individualized functionHigh performanceControl of asynchronous motor is implemented through the high-performance current vector control technology.
Instantaneous stop doesn’t stopThe load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time.
Timing controlTiming range 0.0Min~6500.0Min
Communication methodsRS-485
OperationRunning command channelGiven by the panel, control terminals,
Serial communication port, can be switched by many ways
Frequency source10 kinds of frequency source, given by digital analog voltage, analog current, Pulse, serial port. can be switched by many ways
Auxiliary frequency sourceThere are ten auxiliary frequency sources. It can implement fine tuning of auxiliary frequency and frequency synthesis
Input terminals5 digital input terminals, one of which supports up to 100 kHz high-speed pulse input;
1 analog input terminal, supports 0-10V voltage input or 4–20 mA current input.
Output terminal1 digital output terminal
1 relay output terminal
1 analog output terminal :that supports 0–20 mA current output or 0–10 V voltage output
Display and operation panelLED displayIt displays the parameters.
Key locking andIt can lock the keys partially or completely and define the
function selectionfunction range of some keys so as to prevent mis-function.
Protection modeMotor short-circuit detection at power-on, input output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection.
EnvironmentInstallation locationIndoor, avoid direct sunlight, dust, corrosive gas, combustible gas, oil fog, steam, drip or salt.
AltitudeLower than 1000 m(Lower the grades when using higher then 1000m)
Ambient temperature-10°C ~40°C (Lower the grades if the ambient temperature is between 40°C and 50°C)
HumidityLess than 95%RH, without condensing
VibrationLess than 5.9m/s2(0.6g)
Storage temperature-20℃~+60℃

ZONCN T200 Inverter Introduction


Inverter ModelInput voltageRated output power (KW)Rated input current(A)Rated output current (A)Motor power (KW)
T200-0R4G-21PH AC 220V+/-15%0.45.42.10.4
T200-0R75G-20.757.23.80.75
T200-1R5G-21.5107.21.5
T200-2R2G-22.21692.2
T200-3R7G-23.723133.7
T200-0R4G-43PH AC 380V+/-15%0.43.41.50.4
T200-0R75G-40.753.82.10.75
T200-1R5G-41.553.81.5
T200-2R2G-42.25.85.12.2
T200-3R0G-438.57.23
T200-3R7G/5R5P-43.7/5.510/159/133.7/5.5
T200-5R5G/7R5P-45.5/7.515/2013/175.5/7.5
T200-7R5G/11P-47.5/1120.0/26.017/257.5/11
T200-11G/15P-411/1526/3525/3211/15
T200-15G/18.5P-415/18.535/3832/3715/18.5
T200-18.5G/22P-418.5/2238/4637/4518.5/22
T200-22G/30P-422/3046/6245/6022/30
T200-30G/37P-430/3762/7660/7530/37
T200-37G/45P-437/4576/9275/9037/45
T200-45G/55P-445/5592/11390/11045/55
T200-55G/75P-455/75113/157110/15255/75

FAQ:

Q1, Are you a manufacturer or a trade company?

A. We are a professional VFD Inverter factory since 2005 that focus on producing inverter for 19 years.


Q2, This T200 inverter series support NPN and PNP?

A. Yes.


Q3, This T200 series inverters are made of IGBT?

A. Yes, we can produce from 0.4kw to 55kw, all made of IGBT.


Q4. Do you provide any technical support?

A. Sure, you can freel free to use this T200 series inverter, if there is any questions, pls feel free to let me know. Our technology person will support you.



China Pump Inverter VFD 380v 3phase 2.2kw Variable Speed Drive 3hp Vsd for fan pump supplier

Pump Inverter VFD 380v 3phase 2.2kw Variable Speed Drive 3hp Vsd for fan pump

Inquiry Cart 0