High Protection IP65 Pump Inverter VFD 220v 380v AC Drives 0.75kw 1.5kw 2.2kw

Brand Name:ZONCN
Certification:CE
Model Number:Z5200A01D5K-BF
Minimum Order Quantity:1 Unit
Delivery Time:within 15 days
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Wuhu Anhui China
Address: BLDG 16, #29 Rongyue Dongfang, Guandou Street, Jiujiang District, Wuhu City, Anhui Province 
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

High Protection IP65 Pump Inverter VFD 220v 380v AC Drives 0.75kw 1.5kw 2.2kw

VFD inverter Features

Z5000/H5000 is a high protection grade frequency inverter for the speed control of asynchronous/induction motor. This series of inverter has the characteristics of excellent software performance, simple and easy to use; The hardware is designed with high reliability; and the protection level is IP65/IP54.

Z5000/H5000 Series inverter can be used for all kinds of open loop vector control applications, especially suitable for occasions that have strict requirements on reliability, and use environment.

VFD inverter Technical Specification

ITEMZ5000-BF Series VFD Inverter
Standard functionsControl modeSensorless flux vector control (SFVC)
Voltage/Frequency (V/F) control
Maximum frequencyVector control: 0–320 Hz
V/F control: 0–3200Hz
Carrier frequency1 kHz–16 kHz
The carrier frequency can be automatically adjusted based on the load features.
Input frequency resolutionDigital setting: 0.01 Hz
Analog setting: maximum frequency x 0.025%
Startup torqueG type: 0.5 Hz/150% (SFVC);
P type: 0.5 Hz/100%
Speed range1:100 (SFVC)
Speed stability accuracy± 0.5% (SFVC)
Overload capacityG type: 60s for 150% of the rated current, 3s for 180% of the rated current.
P type: 60s for 120% of the rated current, 3s for 150% of the rated current
Torque boostFixed boost
Customized boost 0.1%–30.0%
V/F curveStraight-line V/F curve
Multi-point V/F curve
N-power V/F curve (1.2-power, 1.4-power, 1.6-power, 1.8-power, square)
V/F separationTwo types: complete separation; half separation
Ramp modeStraight-line ramp
S-curve ramp
Four groups of acceleration/deceleration time with the range of 0.0–6500.0s
DC brakingDC braking frequency: 0.00 Hz to maximum frequency; Braking time: 0.0-36.0s;
Braking action current value: 0.0%–100.0%
JOG controlJOG frequency range: 0.00–50.00 Hz
JOG acceleration/deceleration time: 0.0–6500.0s
Onboard Multiple preset speedsIt implements up to 16 speeds via the simple PLC function or by input(X) terminal states
Onboard PIDIt realizes process-controlled closed loop control system easily.
Auto voltageIt can keep constant output voltage automatically when the mains voltage changes.
regulation (AVR)
Over-voltage/The current and voltage are limited automatically during the running process so as to avoid frequent tripping due to over-voltage/over-current.
Over-current stall
control
Torque limit and torque controlIt can limit the torque automatically and prevent frequent over-current tripping during the running process.
Instantaneous stop doesn’t stopThe load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time.
Rapid current limitIt helps to avoid frequent over-current faults of the AC drive.
High performanceControl of asynchronous motor is implemented through the high-performance current vector control technology.
Timing controlTime range: 0.0–6500.0 minutes
Communication methodsRS485
Running command channelGiven by the panel, control terminals,
Serial communication port, can be switched by many ways
Frequency source10 kinds of frequency source, given by
Digital analog voltage, analog current, Pulse, serial port. can be switched by many ways
Auxiliary frequency source10 kinds of Frequency source, given by Digital analog voltage, analog current, pulse, serial port. Can be switched by many ways.
Input and outputInput terminals6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input.(S3)
2 analog input terminal,one of which only supports 0-10V voltage input and the other supports 0–10 V voltage input and 4–20 mA current input.
Output terminal1 digital output terminal
1 relay output terminal (RA.RB.RC)
1 analog output terminal :that supports 0–20 mA current output or 0–10 V voltage output
Frequency sourceDigital setting, analog voltage setting, analog current setting, pulse setting and serial communication port setting.
LED displayIt displays the parameters.
Key locking and function selectionIt can lock the keys partially or completely and define the function range of some keys so as to prevent malfunction.
Protection modeMotor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection.

VFD Specification

VFD ModelInput voltageRated Output Power (KW)Rated Input current (A)Rated Output Current (A)Motor Power (kW)
Z5200A00D7K-BF1PH AC220V ±15%0.757.250.75
Z5200A01D5K-BF1.51071.5
Z5200A02D2K-BF2.216112.2
Z5400A0D75K-BF3PH AC380V ±15%0.753.82.50.75
Z5400A1D5K-BF1.553.71.5
Z5400A02D2K-BF2.25.852.2
Z5400A03D7K-BF3.71093.7
Z5400A05D5K-BF5.515135.5
Z5400A07D5K-BF7.520177.5
Z5400A0011K-BF11262511
Z5400A0015K-BF15353215
Z5400A0018K-BF18.5383718.5
Z5400A0022K-BF22464522
Z5400A0030K-BF30626030
Z5400A0037K-BF37767537
Z5400A00160K-BF160  160

VFD inverter Nameplate Description

Inverter Application


FAQ

1. What is the control model of this Z5000/H5000 series inverter?

A: Both V/F control and vector control;


2. Does this series of inverter built-in PID control?

A. Yes.


3. Does this series inverter support Analog voltage input(0-10V) and Analog current input (4-20mA)?

A. Yes, through the switch SW1.


4. This series of inverter can be mounted directly on the motor?

A. Yes, Z5000/H5000 series inverter can be mounted directly on the motor or to the wall.


China High Protection IP65 Pump Inverter VFD 220v 380v AC Drives 0.75kw 1.5kw 2.2kw supplier

High Protection IP65 Pump Inverter VFD 220v 380v AC Drives 0.75kw 1.5kw 2.2kw

Inquiry Cart 0