Add to Cart
A10VSO series 31 Variable Axial piston pumps , Open circuit Medium pressure pump
Control device
Filtration of the hydraulic fluid
Finer filtration improves the cleanliness level of the hydraulic
fluid, which increases the service life of the axial piston unit.
A cleanliness level of at least 20/18/15 is to be maintained
according to ISO 4406.
At very high hydraulic fluid temperatures (maximum 110 °C, measured
at port L, L1), at least a cleanliness level of 19/17/14 according
to ISO 4406 is necessary.
Please contact us if the above classes cannot be observed.
DFR/DFR1 – Pressure flow controller
In addition to the pressure controller function (see page 11), a
variable orifice (e.g. directional valve) is used to adjust the
differential pressure upstream and downstream of the orifice. This
is used to control the pump flow.
The pump flow is equal to the actual hydraulic fluid quantity
required by the consumer. With all controller combinations, the Vg
reduction has priority.
Basic position in depressurized state:Vg max.
Setting range1) to 280 bar.
For pressure controller data see page 11
Technical data
Size 18 (A10VSO).
Sizes 28 to 140 (A10VO).
Nominal pressure 280 bar.
Maximum pressure 350 bar.
Open circuit.
Features
Variable pump with axial piston rotary group in swashplate design for hydrostatic drives in open circuit.
The flow is proportional to the drive speed and displacement.
The flow can be infinitely varied by adjusting the swashplate angle.
2 drain ports.
Excellent suction performance.
Low noise level.
Long service life.
Favorable power/weight ratio.
Versatile controller range.
Short control time.
The through drive is suitable for adding gear pumps and axial piston pumps up to the same size, i.e., 100% through drive.