Product Description:
The working principle of the internal storage pressure
SEvofluoropropane fire extinguishing system mainly includes three
links: detection and alarm, fire extinguishing agent release, and
fire extinguishing implementation, as follows:
Detection alarm
Fire detection equipment such as smoke detector and temperature
detector are installed in the protection area. When a fire occurs
in the protection area, smoke, high temperature, etc., the detector
detects the fire signal, and the detector converts the fire signal
into an electrical signal and transmits it to the alarm fire
extinguishing controller. The controller automatically emits sound
and light alarm to remind the personnel in the protected area to
evacuate as soon as possible.
Fire extinguishing agent release
Unit independent system: the alarm and fire control controller
starts the linkage device after logical judgment, and after a
period of delay (generally about 30 seconds), sends out the system
start signal to start the container valve on the gas cylinder
group. After the container valve on the drive gas cylinder group is
opened, the drive gas is released, and the container valve of the
fire extinguishing agent cylinder group is opened along the drive
gas pipeline. The fire extinguishing agent of each cylinder group
is collected through the connecting pipe to the collector pipe, and
the fire extinguishing agent is sent to the sprinkler installed in
the protection area through the fire extinguishing agent conveying
pipe.
Combined distribution system: The working flow and logic of the system are basically similar to
that of the unit independent system. When a fire occurs in a
protected area, the controller sends a system start signal, starts
the container valve on the corresponding drive gas cylinder group
in the protected area to release the drive gas, opens the selection
valve leading to the fire protection area, and drives the gas to
open the container valve of the corresponding fire extinguishing
agent cylinder group along the pipeline. The extinguishing agent of
each bottle group is collected to the collector through the
connecting pipe, and reaches the sprinkler installed in the
protection area through the selection valve for spraying and
extinguishing.
Fire suppression operation
Sevofluoropropane fire extinguishing agent is sprayed into the
protected area in liquid form, and the liquid fire extinguishing
agent quickly transforms into a gaseous state when ejecting the
nozzle, absorbing a lot of heat and significantly reducing the
temperature around the protected area and the flame. At the same
time, heptafluoropropane decomposed into CF₃, CF₂ ₃, CF₃CFO and CFO
under high temperature. These fluorine-containing free radicals
react with active free radicals such as H, O, · OH, HO₂, · O2 ⁻,
and NO · in the combustion reaction process to produce CO₂, H₂O,
HF, etc., thus interrupting the chemical chain reaction in the
combustion process to achieve fire suppression.
Technical Parameters:
Product Name | FM200 Gas Suppression System |
Starting Mode | Automatic, Electrical Manual, Mechanical Emergency |
Maximum Working Pressure | 8MPA(20°C) |
Scope of Work | 0°C~50°C |
Fire Extinguishing Design Concentration | 8~10℃ |
Filling Density | ≤1080kg/m3 |
Storage Pressure | 5.6MPA(20°C) |
Pattern of Extinguishing | Enclosed Flooding |
System Blowdown Time | Computer Room ≤8s, Other ≤10s |
Applications:
Aerosol Fire Suppression System: The xinlin FM200 Gas Suppression System is an ideal solution for
use in aerosol fire suppression systems. This product is designed
to quickly extinguish fires in enclosed spaces, such as server
rooms, data centers, and other areas where sensitive electronic
equipment is stored.
HFC227ea Fire Suppression System: The xinlin FM200 Gas Suppression System is also a highly effective
solution for use in HFC227ea fire suppression systems. This product
is designed to quickly extinguish fires in enclosed spaces, such as
control rooms, electrical rooms, and other areas where flammable
liquids and gases are present.
FM 200 Fire Alarm System: The xinlin FM200 Gas Suppression System can also be integrated
with a fire alarm system to provide additional protection against
fires. This product is designed to automatically extinguish fires
when a fire alarm is triggered, helping to prevent damage to
property and reduce the risk of injury to people.
The xinlin FM200 Gas Suppression System is certified by UL, FM,
CMA, and CNAS, ensuring that the product meets the highest
international standards for quality and safety. The minimum order
quantity for this product is 1, and the price is negotiable. The
product is packaged in a plywood outer box with bubble bag or
paper, and delivery time is 10-15 working days after payment or
receipt of L/C. Payment terms include L/C, D/A, D/P, T/T, Western
Union, and MoneyGram. The supply ability for this product is 20000
sets per week.
The xinlin FM200 Gas Suppression System has a system blowdown time
of ≤8s for computer rooms and ≤10s for other applications. The
pattern of extinguishing is enclosed flooding, and the filling
density is ≤1080kg/m3. The maximum working pressure for this
product is 8MPA(20°C), and the starting mode is automatic,
electrical manual, and mechanical emergency.
Why choose us:
• Efficient management system
• More than 10 years of experience in gas fire fighting industry
• Advanced equipment and professional engineers
• We provide 8×6 hr technical support and after-sales service
Frequently Asked Questions
-----------------------------------------------------------------------------------
Q1Are you a manufacturer or a trading company?
A1: We are the manufacturer.
Q2: Do you have OEM orders?
A2: Yes, according to the customer's requirements.
Q3: Where is your factory located? How do I get there?
A3: Our factory is located in Dongzhou Industrial Park, Xintang
Town, Zengcheng District, Guangzhou City, Guangdong Province,
China.
You are very welcome to visit our factory.