Product Identification and Basics
The X20PS3300, recognized by its material number, is a supply module developed by B&R. It plays a fundamental role in industrial control systems. This module is designed to provide power for both the X2X Link and the internal I/O supply. Its presence is crucial for ensuring the smooth operation of industrial setups that rely on the X2X Link for communication and internal I/O functions. The basic configuration of the module makes it an essential part of any system that requires stable power supply for these components.
Technical Features
One of the notable technical features of the X20PS3300 is the electrical isolation between the feed and the X2X Link supply. This isolation enhances the safety and reliability of the system by preventing electrical interference. Additionally, it allows for the redundancy of the X2X Link supply. By operating multiple supply modules simultaneously, the system can maintain its functionality even in case of a failure in one module. This feature is highly beneficial in industrial environments where continuous operation is critical.
Application - Oriented Advantages
In industrial applications, the X20PS3300 offers significant
advantages. Its ability to power the X2X Link and internal I/O
ensures seamless communication and operation of various devices
within the industrial control system. The electrical isolation
protects sensitive components from potential electrical damage. The
redundancy feature of the X2X Link supply minimizes the risk of
system downtime due to power failures. This makes the X20PS3300 an
ideal choice for industries such as manufacturing, where
uninterrupted production is essential.
Category | Details |
General Information | |
- Material Number | X20PS3330 |
- Brand | B&R |
- Product Type | Power Supply Module |
- Function | Provide power for X2X Link and internal I/O supply, with electrical
isolation and support for redundancy in X2X Link supply |
- B&R ID Code | Not specified in available sources, may need to check official
B&R documentation |
- Warranty | Usually around 12 months, but this can vary depending on region and
distributor |
- Status Indicators | Likely has indicators for power status, module operation status,
and potentially for redundancy status if applicable |
- Diagnostics | Module run/error diagnostics available via LED status indicators
and software. May also be able to diagnose issues related to power
output, isolation, and redundancy |
- Power Consumption | Power consumption details for the module itself (e.g., power used
for internal operations) not found in provided sources. For power
output, it supplies power for X2X Link and internal I/O, but
specific current and voltage consumption values for these outputs
are not given. |
Power Specifications | |
- Input Voltage | Information not available in provided sources. Check B&R
product documentation for the correct input voltage range, which is
likely to be a common industrial voltage such as 24 VDC or 110 -
230 VAC |
- Output Voltage for X2X Link | Not specified. Expected to be a voltage suitable for powering the
X2X Link communication system within the B&R X20 system |
- Output Voltage for Internal I/O | Not given. Will be a voltage appropriate for the internal I/O
components of the X20 system, which could be 24 VDC for digital I/O
and other voltages for analog I/O depending on the system
requirements |
- Output Current Capacity for X2X Link | Not provided. This value would determine the amount of current the
module can supply to the X2X Link to ensure proper communication
and operation |
- Output Current Capacity for Internal I/O | Not found in sources. It should be sufficient to power all the
internal I/O modules connected to the X20 system |
- Voltage Regulation | Details on how well the module regulates the output voltage (e.g.,
voltage tolerance, ripple voltage) are not available. Good voltage
regulation is expected to ensure stable power supply to connected
components |
- Electrical Isolation | Electrical isolation between the feed and X2X Link supply is a
feature. The degree of isolation (e.g., isolation voltage rating)
is not specified. Isolation helps prevent electrical interference
and protects components from voltage spikes |
- Redundancy | Redundancy of X2X Link supply is possible by operating multiple
supply modules simultaneously. However, details on how the
redundancy is implemented (e.g., automatic switch - over time, load
- sharing mechanism) are not given |
Environmental Conditions | |
- Mounting Orientation | Most likely can be mounted horizontally and vertically, but this is
an assumption as the information is not in the provided sources.
Check B&R documentation for the correct mounting orientation
requirements |
- Installation Elevation above Sea Level | No data available. In general, for industrial electronics, there
may be limitations or derating requirements at high elevations.
Check B&R product manual for details |
- Degree of Protection per EN 60529 | Protection class not specified. Common protection classes for such
modules in industrial control systems could be IP20 (suitable for
indoor use, protected against solid objects larger than 12 mm) or
higher if it needs to be used in more demanding environments |
- Temperature (Operation) | Operating temperature range not provided. Industrial power supply
modules typically have an operating temperature range, such as - 25
°C to 60 °C, to withstand different industrial environments. Check
official B&R documentation |
- Temperature (Storage) | Storage temperature range not given. Usually, the storage
temperature range is wider than the operating range, perhaps - 40
°C to 85 °C. Confirm with B&R |
- Relative Humidity (Operation) | Relative humidity range during operation not available. In
industrial applications, modules are often designed to operate in a
relative humidity range like 5% - 95%, non - condensing. Check
product details |
- Relative Humidity (Storage) | Storage relative humidity range not specified. Similar to
operation, it is likely to be in a non - condensing range, but the
exact values need to be verified with B&R |
Mechanical Properties | |
- Physical Dimensions (W x H x D) | Dimensions not provided in sources. The size of the module will be
designed to fit into the B&R X20 system's mounting structure.
Check B&R product manual for accurate dimensions |
- Weight | Weight of the module is not given. It can be important for
installation and shipping considerations. Check official B&R
documentation for the weight value |
- Mounting Mechanism | Mounting method not specified. It is likely to be designed to be
easily mounted on a standard DIN rail or a specific mounting
structure within the X20 system. Refer to B&R product
information |
Certifications | |
- CE | Given the nature of B&R products and their use in industrial
applications, it is likely CE - certified, but this is not
confirmed in the provided sources. CE certification indicates
compliance with European safety, health, and environmental
protection regulations |
- UL | May be UL - listed, but no information is available. UL listing
shows compliance with safety standards in the United States and
Canada. Check B&R product documentation for UL status |
- Other Certifications | There could be other relevant certifications depending on the
intended application, such as certifications for use in hazardous
environments (e.g., ATEX for explosive atmospheres), but no
information is provided in the given sources |