S3000 PROFINET IO Advanced S30A-7111CP - SICK part no : 1045654

Brand Name:SICK
Certification:3C
Model Number:S30A-7111CP
Minimum Order Quantity:1
Delivery Time:3 day
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Xiamen Guangdong China
Address: 903-3, building F02, phase III Software Park, Jimei district, Xiamen city,CHINA (361000)
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
Features
UsageS3000 PROFINET IO does not have any local inputs or outputs and is only operated in a net-
work with corresponding controller.
ModelSensor without system plug
ApplicationIndoor
Protective field range7 m
Warning field range49 m (20 m at 20 % reflectivity)
Distance measuring range49 m
Number of simultaneously monitored pro-
tective fields
2
Type of field setDual field sets
Number of field sets4
Number of fields8
Number of monitoring cases4
Scanning angle190°
Resolution (can be configured)30 mm, 40 mm, 50 mm, 70 mm, 150 mm
Angular resolution0.5°, 0.25°, depending on range and resolution
Response time60 ms 1)
Protective field supplement100 mm
Number of multiple samplings2 ... 16, configurable
Delay of automatic reset120 ms ... 4,920 ms, configurable
1)Depending on basic response time and multiple sampling.
2 SAFETY LASER SCANNERS | SICK Product data sheet | 2025-02-19 13:38:30
Subject to change without notice
S30A-7111CP | S3000 PROFINET IO Advanced
SAFETY LASER SCANNERS
Safety-related parameters
TypeType 3 (IEC 61496)
Safety integrity levelSIL 2 (IEC 61508)
CategoryCategory 3 (EN ISO 13849)
Performance levelPL d (EN ISO 13849)
PFHD (mean probability of a dangerous fail-
ure per hour)
8.0 x 10-8
TM (mission time)20 years (EN ISO 13849)
Safe state in the event of a faultThe safety-related data is logic 0.
Functions
Restart interlock
Multiple sampling
Monitoring case switching
Simultaneous monitoring
Static protective field switching
Contour as a reference
Integrated configuration memory
Measured data outputVia RS-422
Interfaces
Connection type
Bus connection
Supply connection

Copper conductor (2 female connectors for RJ-45 push-pull plug)
System plug with or without connecting cable
Configuration and diagnostics interfaceRS-232
Transmission rate9.6 kBaud, 19.2 kBaud, 38.4 kBaud
Fieldbus, industrial network
Type of fieldbus integration
Device properties
PROFINET PROFIsafe

Integrated in the device
PROFINET IO device with 2-port real-time switch according to PROFINET specification V2.2
PROFIsafe profile with 6-octet input and 6-octet output according to IEC 61784-3-3 V2.4
Cycle time 4, 8, 16, 32 ms, etc.
GSDML according to GSDML specification V2.25
Switch propertiesFiltering Data Base according to IEEE 802.1D
6 prioritization levels for IEEE 802.1Q – Network prioritization
64 KB SRAM memory for caching telegrams, managed in 768-byte segments
Resource prioritization for network control and RTC2/3 frames
Telegram extension based on "Cut-through"
Port status (Disabled, Blocking, Forwarding)
Support for non-real-time and real-time data transfer
Port propertiesAuto-negotiation
Auto-crossover (MDIX)
Auto-polarity
100Base-TX
Conformance

Topology support
Conformance Class B

SNMP, MIB-2, LLDP according to IEEE 802.1AB
MRP client support
DiagnosticsApplication-related manufacturer-specific channel diagnostics and channel diagnostics for the
PROFIsafe profile, individually switchable
Report system errors
Cable diagnostics
Neighborhood alerts
2025-02-19 13:38:30 | Product data sheet SAFETY LASER SCANNERS | SICK 3
Subject to change without notice
S30A-7111CP | S3000 PROFINET IO Advanced
SAFETY LASER SCANNERS
Support for port statistics
I&M support from I&M0 to I&M4
InterfacesTCP port 9000 and UDP port 30718
RS-232
Functions that are not supportedMulticast communication
Supervisor AR
MAC-pause mechanism in full duplex
Back-pressure in half duplex
Static learning
Broadcast Storm Control
Electronics
Protection classIII (VDE 0106, EN 60950)
Supply voltage Vs24 V DC (16.8 V DC ... 28.8 V DC)
Power consumption0.8 A 1)
1) At 24 V DC without output load.
Mechanics
Dimensions (W x H x D)155 mm x 185 mm x 160 mm
Weight3.3 kg
Housing materialAluminum die cast
Housing colorRAL 1021 (yellow)
Front screen materialPolycarbonate
Front screen surface finishOutside with scratch-resistant coating
Ambient data
Enclosure ratingIP65 (EN 60529)
Ambient operating temperature–10 °C ... +50 °C
Storage temperature–25 °C ... +50 °C
Vibration resistance
Class
IEC 60068-2-6, IEC 60068-2-64, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3

5M1 (IEC 60721-3-5)
Shock resistanceIEC 60068-2-27, IEC 60721-3-5, IEC TR 60721-4-5, IEC 61496-3
Class5M1 (IEC 60721-3-5)
Continuous shock50 m/s², 11 ms
100 m/s², 16 ms
Other information
Type of lightPulsed laser diode
Wave length905 nm
Detectable remission factor1.8 % ... > 1,000 %, reflectors
Laser class1 (21 CFR 1040.10 and 1040.11, IEC 60825-1)
Classifications
ECLASS 5.027272705
ECLASS 5.1.427272705
ECLASS 6.027272705
ECLASS 6.227272705
ECLASS 7.027272705
ECLASS 8.027272705
4 SAFETY LASER SCANNERS | SICK Product data sheet | 2025-02-19 13:38:30
Subject to change without notice
S30A-7111CP | S3000 PROFINET IO Advanced
SAFETY LASER SCANNERS
ECLASS 8.127272705
ECLASS 9.027272705
ECLASS 10.027272705
ECLASS 11.027272705
ECLASS 12.027272705
ETIM 5.0EC002550
ETIM 6.0EC002550
ETIM 7.0EC002550
ETIM 8.0EC002550
UNSPSC 16.090139121528
China S3000 PROFINET IO Advanced S30A-7111CP - SICK  part no : 1045654 supplier

S3000 PROFINET IO Advanced S30A-7111CP - SICK part no : 1045654

Inquiry Cart 0