Features
ModuleI/O module
Configuration methodVia software (Flexi Soft Designer, Safe EFI-pro System: Safety Designer)
Safety-related parameters
Safety integrity levelSIL 3 (IEC 61508)
CategoryCategory 4 (EN ISO 13849)
Performance levelPL e (EN ISO 13849)
PFHD (mean probability of a dangerous fail-
ure per hour)
4.8 x 10-9 (EN ISO 13849) 1)
0.9 x 10-9 (EN ISO 13849) 2)
TM (mission time)20 years (EN ISO 13849)
1) For single channel outputs.
2) For dual channel outputs.
Functions
Flexi Loop-compatible
Fast shut-off
Fast shut-off time8 ms
Interfaces
Number of safety inputs8
Number of test outputs2
Number of safe outputs4
Connection typePlug-in spring terminals
2 SAFETY CONTROLLERS | SICK Product data sheet | 2024-11-27 22:21:16
Subject to change without notice
FX3-XTIO84002 | Flexi Soft
SAFETY CONTROLLERS
Electrical data
Protection classIII (EN 61140)
Voltage supplyVia FLEXBUS+
Internal power consumption≤ 2.2 W 1)
Inputs
Input voltage HIGH
Input voltage LOW
Input current HIGH
Input current LOW

13 V DC ... 30 V DC

–5 V DC ... 5 V DC

2.4 mA ... 3.8 mA

–2.5 mA ... 2.1 mA
Test outputs
Voltage supplyVia FLEXBUS+
Type of outputPNP semiconductors, short-circuit protected
Test pulse generator2
Output voltage HIGH15 V DC ... 30 V DC
Output current≤ 120 mA 2)
Outputs
Voltage supplyVia A1, A2
Supply voltage24 V DC (16.8 V DC ... 30 V DC)
Type of supply voltagePELV or SELV 3)
Type of outputPNP semiconductors, short-circuit protected
Output voltage HIGH16 V DC ... 30 V DC
Output current≤ 2 A
1) Via FLEXBUS+, without streams attest outputs.
2) On each of the two test pulse generators. This makes max. 8 testable safe series connections possible per module, each with max. 30 mA.
3) The current of the power supply that powers the module must be limited to a maximum of 4 A, either through the power supply itself or a fuse.
Mechanical data
Dimensions (W x H x D)22.5 mm x 96.5 mm x 120.6 mm
Weight164 g (± 5 %)
Ambient data
Enclosure ratingIP20 (EN 60529)
Ambient operating temperature–25 °C ... +55 °C
Storage temperature–25 °C ... +70 °C
Air humidity≤ 95 %, Non-condensing
Classifications
ECLASS 5.027243001
ECLASS 5.1.427243101
ECLASS 6.027243101
ECLASS 6.227243101
ECLASS 7.027243101
ECLASS 8.027243101
ECLASS 8.127243101
ECLASS 9.027243101
2024-11-27 22:21:16 | Product data sheet SAFETY CONTROLLERS | SICK 3
Subject to change without notice
FX3-XTIO84002 | Flexi Soft
SAFETY CONTROLLERS
ECLASS 10.027243101
ECLASS 11.027243101
ECLASS 12.027243101
ETIM 5.0EC001449
ETIM 6.0EC001449
ETIM 7.0EC001449
ETIM 8.0EC001449
UNSPSC 16.090132151705
China Sick - FX3-XTIO84002 FLEXI SOFT EXTENSION UNIT  Part no : 1044125 supplier

Sick - FX3-XTIO84002 FLEXI SOFT EXTENSION UNIT Part no : 1044125

Inquiry Cart 0