LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime

Brand Name:IFM
Certification:3C
Model Number:LDL100
Minimum Order Quantity:1
Delivery Time:3 day
Payment Terms:T/T
Contact Now

Add to Cart

Verified Supplier
Location: Xiamen Guangdong China
Address: 903-3, building F02, phase III Software Park, Jimei district, Xiamen city,CHINA (361000)
Supplier`s last login times: within 1 hours
Product Details Company Profile
Product Details
Product characteristics
Number of inputs and outputsNumber of analog outputs: 1
Process connectionG 1/2 external thread
Application
Systemgold-plated contacts
MediaConductive liquids
Note on mediawater
milk
CIP liquids
Cannot be used forSee the operating instructions, chapter "Function and features".
Medium temperature [°C]-25...100; (< 1 h: 150)
Pressure rating [bar]16
Vacuum resistance[mbar]-1000
Electrical data
Operating voltage[V]18...30 DC
Current consumption [mA]< 60
Protection classIII
Reverse polarity protectionyes
Power-on delay time[s]2
Inputs / outputs
Number of inputs and outputsNumber of analog outputs: 1
Outputs
Total number of outputs1
Output signalanalog signal;IO-Link
Output functionanalog output; scalable; selectable conductivity / temperature
Number ofanalog outputs1
Analog current output[mA]4...20
Max. load[Ω]500
ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Measuring/setting range
Measuring range[µS/cm]100...15000
Temperature measurement
Measuring range[°C]-25...150
Accuracy / deviations
Accuracy (in the measuring10 % MW ± 25 µS/cm
range)
Conductivity measurement
Resolution[µS/cm]1
Drift[%/K]0,2 %/K MW ± 25 µS/cm
Repeatability5 % MW ± 25 µS/cm
Long-term stability1 % MW ± 25 µS/cm
Temperature measurement
Accuracy[K]20...50 °C: < ± 0,5 K;
-25...150 °C: < ± 1,5 K
Repeatability[K]2
Resolution[K]0.1
Reaction times
Conductivity measurement
Response time [s]< 2; (T09; Damping = 0)
Temperature measurement
Response time [s]< 9; (T09)
Interfaces
Communication interfaceIO-Link
Transmission typeCOM2 (38,4 kBaud)
IO-Link revision1.1
SDCI standardIEC 61131-9
IO-Link device ID0x000399 / 921
ProfilesMeasuring Sensor, Identification and Diagnosis
SIO modeno
Required master port classA
Process data analogue1
Min. process cycle time [ms]5.6
Operating conditions
Ambient temperature [°C]-40...60
Storage temperature [°C] -40...85
Protection IP 68; IP 69K; (IP 68: 7 days / 3 m water depth / 0.3 bar)
Tests / approvals
EMCDIN EN 61000-6-2
DIN EN 61000-6-3
Shock resistanceDIN EN 60068-2-2750 g (11 ms)
Vibration resistanceDIN EN 60068-2-620 g (10...2000 Hz)
MTTF [years]172
ifmefector, inc. • 1100 Atwater Drive • Malvern • PA 19355 — We reserve the right to make technical alterations without prior notice. — EN-US — LDL100-01 — 13.09.2019 —
LDL100
Conductive conductivity sensor
COND CONDUCTIVITY HYG G1/2
Mechanical data
Weight [g]270.5
Materialstainless steel (1.4404 / 316L); PEEK; PEI; FKM
Materials (wetted parts) PEEK; stainless steel (1.4404 / 316L)
Process connection G 1/2 external thread
Remarks
RemarksMW = Measured value
Pack quantity1 pcs.
Electrical connection
China LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime supplier

LDL100 Conductive Conductivity Sensor Ifm Compact Sensor Design Prevents Failures And Unplanned Downtime

Inquiry Cart 0