X20SL8100 B&R PLC Module with POWERLINK Interfaces


Product Description



Material number:

X20SL8100

Description:

  • openSAFETY manager for up to 100 SafeNODEs

  • Flexibly programmable using Automation Studio / SafeDESIGNER

  • Innovative management of safe machine options (SafeOPTION)

  • Parameter and configuration management

The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3.

In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed by the SafeLOGIC controller.


Product Information




Short description

Interfaces

POWERLINK

System module

CPU

General information

B&R ID code

0xDD61

System requirements


Automation Studio

4.0.16 or later

Automation Runtime

V3.08 or later (for AsSafety library F4.06 or later)

SafeDESIGNER

3.1.0 or later

Safety Release

1.7 or later

mapp Technology Package

mapp Safety 5.7.0 or later

Cooling

Fanless

Status indicators

CPU function, POWERLINK, SafeKEY

Diagnostics


CPU function

Yes, using LED status indicator

POWERLINK

Yes, using LED status indicator

SafeKEY

Yes, using LED status indicator

Support


Dynamic node allocation (DNA)

Yes

Power consumption

4.3 W

Additional power dissipation caused by actuators (resistive) [W]

-

Certifications


CE

Yes

UKCA

Yes

Functional safety

cULus FSPC E361559
Energy and industrial systems
Certified for functional safety
ANSI UL 1998:2013

Functional safety

IEC 61508:2010, SIL 3
EN 62061:2005/A2:2015, SIL 3
EN ISO 13849-1:2015, Cat. 4 / PL e
IEC 61511:2004, SIL 3

Functional safety

EN 50156-1:2004

ATEX

Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X

UL

cULus E115267
Industrial control equipment

HazLoc

cCSAus 244665
Process control equipment
for hazardous locations
Class I, Division 2, Groups ABCD, T5

DNV

Temperature: A(0 to 45°C)
Humidity: B(up to 100%)
Vibration: A(0.7 g)
EMC: B(bridge and open deck)

CCS

Yes

LR

ENV1

KR

Yes

ABS

Yes

BV

EC21B
Temperature: 5 - 45°C
Vibration: 0.7 g
EMC: Bridge and open deck

Safety characteristics

EN ISO 13849-1:2015


Category

Cat. 4

PL

PL e

DC

>94%

MTTFD per channel

2500 years

Mission time

Max. 20 years

IEC 61508:2010,
IEC 61511:2004,
EN 62061:2013


SIL CL

SIL 3

SFF

>90%

PFH / PFHd per channel

<1*10-10

PFH / PFHd


openSAFETY wired

Negligible

openSAFETY wireless

<1*10-14* Number of openSAFETY packets per hour

PFD per channel

<2*10-5

Proof test interval (PT)

20 years

Functionality

Communication with each other

Yes

Support for Safe Commissioning Options


BOOL

512

INT

64

UINT

64

DINT

64

UDINT

64

SafeMOTION support

Yes, depends on the number of available operating licenses on the SafeKEY

Max. number of SafeMOTION axes

70, depends on the data width of the modules used

Timing precision

Time * 0.05 + Cycle time of the safety application

Shortest task class cycle time

1 ms

Max. number of SafeNODEs

100, depends on the number of available operating licenses on the SafeKEY

Max. number of POWERLINK controlled nodes

50

Data exchange between CPU and SafeLOGIC controller


Max. total data width for each direction

512 bytes

Max. number of data points for each direction


BOOL

1024

INT

128

UINT

128

DINT

64

UDINT

64

Data exchange between SafeDOMAIN and SafeDOMAIN


Use as Managing SafeDOMAIN

Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0

Use as Connected SafeDOMAIN

Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0

Max. total data width for each direction

64 bytes

Max. total number of data points for each direction

16

Max. number of data points for each direction


BOOL

128

INT

16

UINT

16

DINT

16

UDINT

16

Max. number of linked Managing SafeDOMAINs

Starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0: 10

Limit values for SafeDESIGNER application

Max. resources available for SafeDESIGNER info window entries


FB instances

4096

Marker memory

262,144 bytes

Stack memory

32,768 bytes

Memory for safe input data

6144 bytes

Memory for safe output data

2048 bytes

Memory for standard input data

1024 bytes

Memory for standard output data

1024 bytes

Marker count

16,382

Additional SafeDESIGNER limit values


Max. number of function block types

512

Max. number of force variables

64

Max. number of variable with variable status

1023

Input SL / BC / X2X Link power supply

Input voltage

24 VDC -15% / +20%

Input current

Max. 0.25 A

Fuse

-

Reverse polarity protection

Yes

Interfaces

Fieldbus

POWERLINK controlled node

Variant

2x shielded RJ45 port (hub)

Line length

Max. 100 m between 2 nodes (segment length)

Transfer rate

100 Mbit/s

Transfer


Physical layer

100BASE-TX

Half-duplex

Yes

Full-duplex

No

Autonegotiation

Yes

Auto-MDI/MDIX

Yes

Min. cycle time


Fieldbus

200 µs

Operating conditions

Mounting orientation


Horizontal

Yes

Vertical

Yes

Installation elevation above sea level

0 to 2000 m, no limitation

Degree of protection per EN 60529

IP20

Ambient conditions

Temperature


Operation


Horizontal mounting orientation

0 to 60°C

Vertical mounting orientation

0 to 45°C

Derating

-

Storage

-40 to 85°C

Transport

-40 to 85°C

Relative humidity


Operation

5 to 95%, non-condensing

Storage

5 to 95%, non-condensing

Transport

5 to 95%, non-condensing

Mechanical properties

Note

Order SafeKEY and SafeLOGIC range of functions using the X20MK configurator.
X20 end cover plate (right) included in delivery
12-pin X20 terminal block, safety-keyed, included in delivery
SafeKEY cover included in delivery

Dimensions


Width

62.5+0.2mm

Height

99 mm

Depth

75 mm

Weight

190 g


Product Photo




More Products



X20PS9600X20SO6300X20DC4395
X20CP0483X20SLX210X20BT9100
X20CP1483X20DI4371X20DI9371
x20cp1586X20BM05X20AT6402
X20CP1583X20BC0083X20AI4622
X20CP3584X20BC8083x20at4222
X20CP3583X20BB80x20bt9400
X20CP1585X20BM11X20AT2222
X20CP1584X20TB12X20AO4622
X20CP1684X20IF1072X20DO9322
X20CP1382X20DO6322X20IF1030
X20AI1744X20DC2395X20IF1082-2
X20DI6371X20BM15X20IF371
X20DOF322X20DO4332X20CM4810
X20DS4389X20DO4322X20AI83211
X20PS2100X20MM2436X20DOF322
X20PS9400X20DO8332X20PS3330
X20CS1030X20DC11A6X20BM01
X20CS1020X20CM8281X20SI9100
X20ATC402X20BR9300X20SI4100

Cooperative Brand



(DCS)

ABB / TRICONEX / FOXBORO/ I/A / HONEYWELL / TDC2000/3000 / YOKOGAWA / BENTLY NEVADA

(PLC)

B&R / ALLEN BRADLEY / BECKHOFF / HONEYWELL / OMRON / SIEMENS

(SENSOR)

IFM / SICK/ P+F/ WENGLOR / BAUMER / LEUZE / HOLLY/ SYSHOKUYO / EUCHNER

(CONNECTOR)

HARTING / PHOENIX CONTACT/ WEIDMUELLER

(VALVE)

SMC / FESTO / +GF+.......

(INSTRUMENT)

+GF+ /E+H / HITACHI / ROSEMOUNT


Why Choose Us



Xiamen ZhiCheng Automation Technology Co., Ltd it is a leading global supplier of control system components. We specialize in control systems and drives. With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts. We have tens of thousands of spare partsand spare parts warehouse . Products and services to serve for installing of users control system,Distributed control systems, programmable controllers, panel controller and drive!


We major in DCS system,Sensor,PLC,Connector,Valve, and Instrument,MAGNETRON,RO Membrane. With many years of experience in the industrial sector, we consistently deliver the highest quality of spare parts.which make sure that all this jobs are perfectly. If you have any further questions, please don't hesitate to contact us.


How To Contact Me



China X20SL8100 B&R PLC Module with POWERLINK Interfaces supplier

X20SL8100 B&R PLC Module with POWERLINK Interfaces

Inquiry Cart 0