Add to Cart
The COD sensor is a new generation of environmentally friendly COD
sensor launched by our company. It requires no reagents, no
pollution, and is more economical and environmentally friendly.
Small size and easy installation, water quality monitoring is
available online. Automatic compensation for turbidity
disturbances, with automatic cleaning, for excellent stability even
for long-term monitoring.
Measuring Principle
Many organic substances dissolved in water absorb ultraviolet
light. Therefore, the total amount of organic pollutants in water
can be measured by measuring the absorption of these organic
substances by ultraviolet light at a wavelength of 254 nm. COD
sensors use two light sources, one 254nm ultraviolet light and one
550nm infrared light, which can automatically compensate the
optical path attenuation and turbidity effects, thus achieving more
stable and reliable measurement values.
COD sensor Feature
Specification
Model | BGT-WCOD(K) | ||
Measuring principle | Dual wavelength ultraviolet absorption method | ||
COD Measuring range | COD | Turbidity | |
0~200mg/L equiv. KHP | 0~100NTU | ||
00~500mg/L equiv. KHP | 0~200NTU | ||
COD Precision | ±5%F.S. | ||
COD Resolution | 0.1mg/L | ||
Turbidity range | 0-100NTU | ||
Turbidity accuracy | ±5%F.S. | ||
Turbidity resolution | 0.1NTU | ||
Calibration method | Two-point calibration | ||
Output method | RS-485 bus, Modbus/RTU protocol | ||
Power supply | 12~24VDC | ||
Power consumption | <0.2W@12VDC | ||
Working conditions | 0~45℃, <0.2MPa | ||
Storage temperature | -5~65℃ | ||
Protection level | IP68 | ||
Installation method | Immersion installation | ||
Cable length | 5 meters, other lengths can be customized | ||
Sensor housing material | POM/ 316L stainless steel |
1. Tell us what resistance, color, quantity you want to purchase.