Meter Test Bench for Single Phase Energy Meters

Brand Name:GENY
Certification:ISO, CE
Model Number:YC-1891D
Minimum Order Quantity:1PCS
Delivery Time:30 days after order confirmed
Payment Terms:L/C,T/T,D/P
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
Supplier`s last login times: within 32 hours
Product Details Company Profile
Product Details

Meter Test Bench for Single Phase Energy Meters


Features


  • Supports testing for: Active power, Reactive power, Active energy, Reactive energy

  • Start-up and creep tests

  • Automatic calibration for fast creep and start-up tests

  • Measures basic error, average error, standard deviation, and 24-hour variation

  • Comprehensive influence tests: voltage, frequency, harmonics (2nd–21st), and phase sequence

  • Simultaneous current measurements on the same meter rack

  • Test energy meters without disconnecting voltage or current circuits

  • Built-in protections: current open circuit and voltage short circuit

  • Integrated optical scanning head greatly improves operational efficiency

  • Dual operation modes: automatic and manual

  • PC software for automatic error data processing, storage, and real-time output

  • Data management functions with customizable report printing

  • Barcode input supported

  • Simple and reliable mechanical structure

  • Configurable meter positions: from 3 up to 60 meters

  • Forward/reverse active and reactive energy error testing

  • Time base source SW-5D for measuring daily timing error of energy meters

  • Communication test and broadcast time synchronization

  • Constant verification via pulse counting, timing, or start-stop energy method

  • Load switching test, demand period test, and demand indication error test

  • Register indication and combined register error testing

  • Optional: Power consumption test, tilt influence test, prepaid energy meter test


Technical Specifications


  • Power Supply: AC 220V ±10%, 50Hz ±2Hz

  • Operating Temperature: -10°C to +40°C

  • Humidity Range: 35% to 95%

Voltage Output:

  • Range: 24V – 288V

  • Maximum Output Power: 1000VA

  • Resolution: 0.01%

  • Stability: 0.02% / 120s

  • Load Regulation: 0.01%

  • Distortion: ≤ 0.3% (within full linear load range)

Current Output:

  • Range: 1mA – 120A (max 230A)

  • Maximum Output Power: 2000VA

  • Resolution: 0.01%

  • Stability: 0.02% / 120s

  • Load Regulation: 0.01%

  • Distortion: ≤ 0.3% (within full linear load range)

  • Continuous Current Capacity: 100A

Phase & Frequency:

  • Phase Adjustment Range: 0° – 360°

  • Phase Resolution: 0.01°

  • Frequency Range: 45Hz – 65Hz

  • Frequency Resolution: 0.01Hz

  • Power Output Stability: 0.02% / 120s



China Meter Test Bench for Single Phase Energy Meters supplier

Meter Test Bench for Single Phase Energy Meters

Inquiry Cart 0