Description

  • The YC99T series is a portable three-phase energy meter tester designed for precise calibration in both laboratory and field settings. The YC99T-5C offers the same functionality as the YC99T-3C, with different voltage and current output ranges.
  • It supports IEC protocols, performs a range of tests (e.g., demand errors, time-switching errors), and includes a quartz oscillator for daily time error verification. The YC99T-5C is user-friendly with an intuitive panel design and is capable of generating stable harmonic outputs.

Key Features

  • Accuracy: ±0.05% for voltage, current, and active power; ±0.1% for reactive power.
  • Stability: 0.01%/3min; distortion ≤0.2%.
  • Output Range: Voltage: 57.7V–660V; Current: 1A–50A.
  • Harmonics: Generates up to 63rd harmonic.
  • Data Management: Supports RS232 or PC control for data transfer.
  • Automated Calibration: Fully automates meter calibration.
  • Multi-Protocol: RS485, RS232, and Ethernet compatible.
  • Diagnostics: Fault detection and internal module checks.
  • The YC99T-5C is ideal for efficient, accurate energy meter calibration.

Specification:

Voltage
AC Voltage Range57.7V-660V
Power of the Voltage outputMAX.30VA
Resolution0.01%
Accuracy0.1%
Stability0.01%/120s
Distortion factor0.2%
Current
Test current output1A-50A
Power of the current outputMax. 100VA
Resolution0.01%
Accuracy0.05%
Stability0.01%/180s
Distortion factor< 0.3% for linear resistance load
Phase angle
Range0 -- 360°
Resolution0.01°
Accuracy0.2°
Frequency
Range40Hz – 70Hz
Resolution0.005Hz
Pulse output
Harmonic Output2-63
Pulse input
Input channel3
Input frequencyMax. 20Hz
Other
Voltage Supply220V±15% /110V±15% (optional)
Ambient temperature20°C -- 30°C
Relative humidity≤85%
Dimensions (W×H×D) (mm)500 X 440 X 180
Weight (kg)46(5C)/22(3C)