Professional Stationary Meter Test System for Precise Voltage and Current Output

Brand Name:GENY
Certification:ISO, CE
Model Number:YC1893D
Minimum Order Quantity:1
Delivery Time:6~8weeks
Payment Terms:T/T, L/C, D/P, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Guangzhou China
Address: ROOM 107, 1ST FLOOR, No. 602 GUANGSHAN ER ROAD, TIANHE DISTRICT, GUANGZHOU, CHINA POSTCODE: 510663
Supplier`s last login times: within 32 hours
Product Details Company Profile
Product Details

Professional Stationary Meter Test System for Precise Voltage and Current Output

Technical Data

Power Supply


Voltage
3 ×230/398V±10%
Frequency
50 / 60Hz ±2Hz
Power capacity
>3 ×3kVA
Ambient temperature
-10°C -- +40°C
Relative humidity
35% -- 85%

Voltage output


Test voltage output(Phase-Neutral)3x(24V-300V)
Power of the voltage output3x1000VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h(integration time 150 s)
Load regulation from 0-max. loadBetter than 0.01%
Distortion factorBetter than 0.3% for linear resistance load
Harmonics2nd-21st free programmable

Current Output


Test current output3x(0.3mA-120A)
Power of the current output3x1500VA
ResolutionBetter than 0.01% of full scale value of range
Setting accuracyBetter than 0.05% at the final range value
StabilityBetter than 0.005%/h(integration time 150 s)
Load regulation from 0-max. loadBetter than 0.01%
Distortion factorBetter than 0.3% for linear resistance load
Harmonics2nd-21st free programmable

Phase Angle


Range0-360°
Resolution0.01°
Setting accuracy0.1°

Frequency


Range45Hz-65Hz
Resolution0.01Hz

Features and functions

The test bench mainly has features as below

  • Supporting parallel communication port to test smart meters through RS232
  • Calibrating terminals on the rack for test bench verification
  • Suit for calibration / pulsing test of 3-phase energy meters of EDMI
  • Accuracy Testing of reference standard meter
  • Pre-warming
  • Accuracy test as per IEC
  • Creeping test
  • Starting current test2 of 9
  • Repeatability of error test
  • Dial test
  • Influence quantity test related to accuracy tests (Voltage, Frequency, reverse phase sequence,
  • voltage unbalance)
  • Influence of harmonic component in voltage and current circuit as per IEC
  • Sub Harmonics as per IEC standards (IEC 62052-11 / 62053-21/22/23)
  • Odd Harmonics as per IEC standards

Customized features:

  • Able to do individual (voltage and current separate) and combined (power) calibration and
  • testing
  • Verification – 24+24 positions. At any one time, only 24 positions are running. Only need power supply for 24 positions, have a relay switch (preferably controllable by software) to switch between 1st 24 positions or 2nd 24 positions.
  • Able to work for both CT and WC range; 1(6)A, 1(10)A, 5(20)A, 5(100)A, 5(120)A
  • Able to perform gating and pulse method for calibration and testing
  • Able to run on DLMS protocol for reading and writing to Mk10M meters
  • Able to run on EDMI Command Line for reading and writing to Mk10E meters

Applications:

1. Nation-level utility companies

2. Governmental bureaus of metrology

3. Big energy meter manufacturers


Primary Competitive Advantages:

1. High quality product

2. Over 18 months long warranty

3. High accuracy class: 0.05/0.02

4. Can be customized of Three Phase Electric Energy Meter Test bench

5. Extremely high power stability

6. Neutral current test(optional)

7. Timing error test

8. Influence test of voltage, frequency, and harmonic

9. Installing RS232, Ethernet communication port in each meter position.

10. Tilt impact test (optional)