Product Description:


The countercurrent closed cooling tower (also called evaporative air cooler or closed cooling tower) places a tubular heat exchanger inside the tower, and ensures the cooling effect through the heat exchange between the circulating air, spray water and circulating water. Because it is a closed cycle, it can ensure that the water quality is not polluted, which well protects the efficient operation of the main equipment and increases the service life. When the outside temperature is low, the spray water system can be stopped to save water. With the implementation of the national energy conservation and emission reduction policy and the increasing scarcity of water resources, closed cooling towers have been widely used in industries such as steel metallurgy, power electronics, mechanical processing, and air conditioning systems in recent years.


Product Specification:


Model

No

Nominal

Flow Rate

(Ton)

FanCirculating PumpConnectig Pipe (mm)Overall Dimensions (mm)Weight

Power

(kw)

Air volumn

(m3/s)

Power

(kw)

Air volumn

(m3/h)

inlet/outletmake updrainageLWH

NET

(kg)

Running
(kg)
GTM-1560.552.40.7520DN50DN25DN40220010001830450700
GTM-110120.552.40.7520DN50DN25DN40240010001900490800
GTM-115180.55×22.4×20.7520DN65DN25DN402300102018304601000
GTM-120240.55×22.4×20.7520DN65DN25DN402300102019005001050
GTM-225300.55×22.4×21.545DN80DN25DN402860124020507301650
GTM-230371.1×23.7×21.545DN80DN25DN402860124021808301760
GTM-235431.1×23.7×21.545DN65×2DN25DN4028601240242010502030
GTM-340491.5×25.1×22.260DN65×2DN25DN4028601520244012802500
GTM-350611.5×25.1×22.260DN80×2DN25DN4028601520263013702660
GTM-365791.1×43.7×42.260DN80×2DN25DN4032001760263018203460
GTM-370851.1×43.7×42.2114DN80×2DN25DN4032002120275019303970
GTM-380981.5×45.1×42.2114DN80×2DN25DN4032002120275020504000
GTM-3901101.5×45.1×42.2114DN80×2DN25DN4032002120275021504050
GTM-31001221.5×45.1×42.2114DN80×2DN25DN4035502120275023304710
GTM-31101341.5×65.1×62.2114DN80×2DN25DN4041502120287026505550
GTM-51251521.5×85.1×83.7140DN100×2DN40DN4047502120297031006500
GTM-51501831.5×85.1×83.7140DN100×2DN40DN4050502120312035007480
GTM-71752131.5×85.1×85.5160DN125×2DN40DN4054802120312038008240
GTM-72002441.5×85.1×85.5160DN125×2DN40DN4050802620312048009170
GTM-72252741.5×85.1×85.5160DN125×2DN40DN40548026203220560011300
GTM-102503051.5×105.1×107.5240DN150×2DN40DN40623026203220600012560


Product Workng Theory:


As counter flow towers,the dry cool air is inlet through louvers on both sides of the tower from the bottom,and drawn upwards passing a large heat exchange surface of the coils section under the induced fans,against the spraying water in the opposite way,becoming hot wet air,induced draught out of the tower into the atmosphere by the fans on the top.During this process,a part of the heat from the fluids inside the closed loop is transferred effientiy,and removed to the outside environment.