CCCT Crossflow Closed Cooling Tower Induced Draft Crossflow

Model Number:GHM Series
Place of Origin:Jiangsu, China
Product Name:Closed Cooling Tower
Casing Material:special Mg-Al-Zn alloy coated steel or stainless steel
Capacity:30t-366t
Feature:high efficiency
Contact Now

Add to Cart

Verified Supplier
Location: Wuxi Jiangsu China
Address: Building A3, Tianan Smart City, Xinwu District, Wuxi City, Jiangsu Province
Supplier`s last login times: within 26 hours
Product Details Company Profile
Product Details

CCCT Crossflow Closed Cooling Tower Induced Draft Crossflow Cooling Tower


Product Description:


Crossflow Closed Cooling Towers (CCCT) are an indirect-contact evaporative cooler in which ambient air, spray water, and process fluid work together. The thermal performance of this cooling tower has significant impact on the thermal performance of the system in which it is implemented.

GHM Series are of capacities from 30 to 366 nominal tons, can work in series as a group for larger capacities. Casing made in special Mg-Al-Zn alloy coated steel or stainless steel, Heat exchange coils made in stainless steel or red copper. Wet deck fills made in PVC. All raw materials are of high industrial grade, with superior corrosion resistant features. GHM towers are designed of high efficiency.


Working Theory:


GHM series belong to induced draft type cross flow cooling towers. During the working process, dry cool air is inlet through wide louvers on one side of the tower, then directed through the heat exchanfe coils and wet deck fills across the spray water becoming wet hot air, eventually draught out of the tower into the atmosphere bythe fans on the top.In this process, a part of heat from the fluids inside the closed loop is transferred efficiently, and removed continuously.


Product Application:


Induction Furnace Cooling; Casting Cooling; Automotive Industrial Cooling; Solar Energy Cooling; Chemical Industrial Cooling; Electric Power Cooling; Glass Factory Cooling; IT Server Room Cooling


Product. Specification:


Model

No

Nominal

Flow Rate

(Ton)

FanCirculating PumpConnectig Pipe(mm)OverallDimensions(mm)Weight

Power

(kw)

Air volumn(m3/s)

Power

(kw)

Air volumn(m3/h)inlet/outlemake updrainageLWH

NET

(kg)

Running
(kg)
GHM-225301.1×23.7×21.545DN80DN25DN402540940220010201820
GHM-230371.1×23.7×21.545DN80DN25DN402960940220010502020
GHM-235431.1×23.7×21.545DN80DN25DN4029601940220011002100
GHM-340491.1×33.7×32.260DN80DN25DN4033601940220013102540
GHM-350611.1×33.7×32.260DN80×2DN25DN4033601940273014503080
GHM-365791.5×35.1×32.260DN80×2DN25DN4033601940273015203200
GHM-380981.5×45.1×42.2114DN80×2DN25DN4042202240268020504920
GHM-3901101.5×451x2.2114DN80×2DN25DN4042202240268021005000
GHM-31001221.5×45.1×42.2114DN80×2DN25DN4042202240284021505100
GHM-31101341.5×45.1×42.2114DN80×2DN25DN4042202240284022505250
GHM-51251521.5×45.1×43.7140DN100×2DN40DN4047402240291028006800
GHM-51501832.2×46.3×43.7140DN100×2DN40DN4054402240291032007820
GHM-51752132.2×46.3×43.7140DN125×2DN40DN4054402240291033008000
GHM-72002444x416.7×45.5160DN125×2DN40DMao58402900326050009000
GHM-72252744x416.7×45.5160DN125×2DN40DN4o584029003470550010000
GHM-72503054x416.7×45.5160DN150×2DN40DN40642029003470650011500
GHM-72753354×416.7×45.5160DN150×2DN40DN40642029003470680011800
GHM-73003664×416.7×45.5160DN150×2DN40DN40642029003470700012000

NOTE

Nominal Tons are based upon temp.drop 35~29.5℃/95~85°F,WBT 25.5℃/78°F,and 0.681 m³/hr/ton.