Basic Information | |
describe | CE8851-32CQ4BQ switch (32*100GE QSFP28, 4*200GE QSFP56, 2*AC power
supply, 5*fan box, port side outlet) |
Part Number | 02355RHP-001 |
model | CE8851-32CQ4BQ |
Technical indicators | |
Other parts codes | 02355RHM-001 (CE8851-32CQ4BQ switch (32*100GE QSFP28, 4*200GE
QSFP56, without power supply and fan) ) 02355RHN-001
(CE8851-32CQ4BQ switch (32*100GE QSFP28, 4*200GE QSFP56, 2*AC power
supply, 5*fan box, port side air intake) ) |
Installation | Cabinet installation |
Height [mm] | 43.6mm |
Depth [mm] | 420.0mm |
Width [mm] | 442.0mm |
Chassis height [U] | 1 |
Weight (full configuration, including packaging materials) [kg] | 12.58kg |
Weight (including packaging) [kg] | 10.39kg |
Weight (full configuration, excluding packaging materials) [kg] | 8.31kg (with AC power supply and fan box, excluding optical
modules. If multiple modules are supported, the maximum weight is
used.) |
Weight (excluding packaging materials) [kg] | 6.12kg (without optical module, power supply and fan box) |
Maximum power consumption [W] | 541W (100% load, 32x100G+4x200G short-distance optical modules,
normal temperature, dual AC power supplies) 648W (100% load,
32x100G+4x200G long-distance optical modules, high temperature,
dual AC power supplies) |
Typical power consumption [W] | 378W (100% load, 16x100G+2x200G ports copper cables, normal
temperature, dual AC power supplies) 417W (100% load,
16x100G+2x200G ports short-distance optical modules, normal
temperature, dual AC power supplies) |
Static power consumption | 331W |
Maximum heat dissipation value [BTU/hour] | - 1846 BTU/hour (100% load, 32x100G+4x200G port short-distance
optical modules, normal temperature, dual AC power supplies) - 2211
BTU/hour (100% load, 32x100G+4x200G port long-distance optical
modules, high temperature, dual AC power supplies) |
Typical heat dissipation value [BTU/hour] | - 1290 BTU/hour (100% load, 16x100G+2x200G ports copper cables,
normal temperature, dual AC power supplies) - 1423 BTU/hour (100%
load, 16x100G+2x200G ports short-distance optical modules, normal
temperature, dual AC power supplies) |
Cooling method | Air cooling |
Static heat dissipation value [BTU/h] | 1129BTU/hour |
Power supply type | AC pluggable, DC pluggable, HVDC pluggable |
Rated input voltage [V] | - 1200W AC & 240V DC power module: AC: 100V AC ~ 240V AC,
50/60Hz; DC: 240V DC - 1200W DC power module: -48V DC ~ -60V DC;
+48V DC |
Input voltage range[V] | - 1200W AC & 240V DC power module: AC: 90V AC ~ 290V AC,
45Hz-65Hz; DC: 190V DC ~ 290V DC - 1200W DC power module: -38.4V DC
~ -72V DC; +38.4V DC ~ +72V DC |
Maximum input current [A] | - 1200W AC & 240V DC power module: 10A (100V AC ~ 130V AC); 8A
(200V AC ~ 240V AC); 8A (240V DC) - 1200W DC power module: 38A
(-48V DC ~ -60V DC); 38A (+48V DC) |
Rated output power [W] | - 1200W AC & 240V DC power module: 1200W - 1200W DC power
module: 1200W |
Memory | DRAM:8GB |
NOR Flash Specifications | 64MB |
SSD Flash | 4GB SSD |
USB interface | Can be used for log backup and USB flash drive deployment. This
function is reserved and has not been enabled yet. |
Console Interface Type | RJ45 |
Downlink service port | 32x100G QSFP28+4x200G QSFP56 |
Interfaces that support service port stacking | This function is reserved and has not been enabled yet. |
Real-time Clock (RTC) | support |
Switching capacity [Gbps] | If you need this specification, please check the product brochure
or contact the product salesperson to obtain it. |
Fan redundancy | Supports 4+1 backup and hot backup of fan modules. When a single
fan module fails, the system can still work normally for a short
period of time. However, it is recommended to replace the failed
fan module immediately. |
Power redundancy | 1+1 backup |
Number of power modules | 2 |
Power port lightning protection | AC: Common mode 6kV, differential mode 6kV DC: Common mode 4kV,
differential mode 2kV HVDC: Common mode 4kV, differential mode 2kV |
Fan Type | Pluggable fan |
Number of fans | 5 |
Airflow direction | Port-side air inlet/port-side air outlet is determined by the
selected fan modules and power modules. The air ducts of the fan
modules and power modules must be consistent. |
Storage temperature [°C] | -40°C~+70°C |
Long-term working environment temperature [°C] | 0°C to 40°C (0m to 1800m) Note: At altitudes of 1800m to 5000m, the
maximum temperature specification decreases by 1°C for every 220m
increase in altitude. |
Storage relative humidity [RH] | 5%RH~95%RH, non-condensing |
Long-term working environment relative humidity [RH] | 5%RH~95%RH, non-condensing |
Storage altitude [m] | ≤5000m |
Long-term working altitude [m] | ≤5000m |
MTBF [years] | 27.77 years |
MTTR [hours] | 2 hours |
High temperature 40℃ noise (sound pressure) | Front-to-rear airflow: average 71.5 dB(A) (max: 77.3 dB(A))
Rear-to-front airflow: average 69.7 dB(A) (max: 75.6 dB(A)) |
Noise (sound pressure) at room temperature 27°C | Front-to-rear airflow: average 52.6dB(A) (max: 57.2dB(A))
Rear-to-front airflow: average 53.6dB(A) (max: 59.0dB(A)) |
Availability | 0.999991779 |