2 Axis Diameter Controller High Precision Laser Measuring Device

Brand Name:Screate DALA
Model Number:F2030-K
Minimum Order Quantity:Negotiable
Delivery Time:7 - 15 working Days
Payment Terms:T/T, etc.
Place of Origin:CHINA
Contact Now

Add to Cart

Verified Supplier
Location: Chengdu China
Address: B2-2, No.8 of Electronic Science Park, Wulian 1st Road, Shuangliu District, Chengdu,China
Supplier`s last login times: within 33 hours
Product Details Company Profile
Product Details

Technology of Simple Structure, Long Durability

F2030-k utilizes the laser diffraction measurement method, which is renowned for its straightforward design and exceptional accuracy. The device lacks a motor, making maintenance effortless.
Its small size and uncomplicated structure further simplify upkeep.
With a measurement repeatability of ±0.2 µm, the F2030-k is highly adaptable and suitable for diverse materials including electric wire and cable, steel wire, enamelled copper wire,medical tubing, and 3D filament, irrespective of their transparency.

Single axis sampling frequency of 10KHz

Sampling frequency can reach to 10KHz due to no motor running speed limitation,which enables to get more information of the object under measurement.

Applications



Touch Screen,Computer,Cellphone

DALA F2030-K can be managed by computer ,cellphone and Touch screen,like parameter setting ,measurement data management ,

and so on,customers can choose as their application request.

Technical Specification


ModelF2030-K
Axis2-axis
Measurement datadiameter and ovality, lump and necks
Frequency10KHz(5KHz/axis)
Measurement range0.5~30mm
Repeatability(1)±0.2μm
Accuracy(2)±(0.001+0.01%*D)mm
Min defect height0.01mm
Min defect length(3)0.4mm(wire speed120m/min)
1.6mm(wire speed500m/min)
Size280*245*58mm
Working power source24V ±10% 40VA
Running temperature5℃~50℃
DisplayLED display
Commuincation port

Standard:WIFI,RS485 MODBUS RTU,CAN
Option:PROFIBUS,PROFINET, EtherNet/IP,EtherCAT

Electrical portStandard: digital output(relay),digital input,analog input,encoder pulse input port
Option:PI feedback control (4)
Data colletion & analysisavailable (option DS14 ZT display and control system,DMS1000)
Out-of-tolerance alarmavailable
Transparent modeavailable

Note:

(1) set sliding window as 100ms, outside diameter repeatability of φ1mm round rod at measurement center area

(2) set sliding window as 100ms, outside diameter deviation of φ1mm round rod at measurement area

(3)set defect measurement average time as 0ms, the minimum defect length which cannot be missed at the measurable area

(4)PI feedback control is option, but must order at placing order


China 2 Axis Diameter Controller High Precision Laser Measuring Device supplier

2 Axis Diameter Controller High Precision Laser Measuring Device

Inquiry Cart 0