Add to Cart
HS Series parameter table
Electrical Specifications | |||||||||||
Model HS | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | ||
Inverter Output | Continuous Output Power | 1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10000W | 12000W | |
Surge Rating(20ms) | 3KW | 6KW | 9KW | 12KW | 15KW | 18KW | 24KW | 30KW | 36KW | ||
Output Waveform | Pure Sine wave/Same as input(Bypass Mode) | ||||||||||
Nominal Efficiency | >88%(Peak) | ||||||||||
Line Mode Efficiency | >95% | ||||||||||
Power Factor | 0.9-1.0 | ||||||||||
Nominal Output Voltage rms | 100-110-120Vac / 220-230-240Vac | ||||||||||
Output Voltage Regulation | ±10% RMS | ||||||||||
Output Frequency | 50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||||||
Short Circuit Protection | Yes( 1sec after fault ) | ||||||||||
Typical transfer Time | 10ms(Max) | ||||||||||
THD | < 10% | ||||||||||
DC Input | Nominal Input Voltage | 12.0Vdc / 24.0Vdc / 48.0Vdc | 24.0Vdc / 48.0Vdc | 48.0Vdc | |||||||
Minimum Start Voltage | 10.0Vdc / 10.5Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc; | |||||||||
Low Battery Alarm | 10.5Vdc / 11.0Vdc for 12Vdc Mode | ||||||||||
Low Battery Trip | 10.0Vdc / 10.5Vdc for 12Vdc Mode | ||||||||||
High Voltage Alarm | 16.0Vdc for 12Vdc Mode | ||||||||||
Low Battery voltage recover | 15.5Vdc for 12Vdc Mode | ||||||||||
Idle Consumption-Se arch Mode | < 25 W when Power Saver On.(Refer to Table ) | ||||||||||
Charger | Output Voltage | Depends on battery type (Refer to Table 2.5.2) | |||||||||
Charger Breaker Rating | 10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||
Max Charge Power Rate | 1/3 Rating Power (Refer to Table 2.5.3) | ||||||||||
Battery Initial Voltage for Start | 10-15.7Vdc for 12Vdc Mode | *2 for 24Vdc, *4 for 48Vdc; | |||||||||
Over Charge Protection S.D. | 15.7Vdc for 12Vdc Mode | ||||||||||
BTS | Battery Temperature Sensor (Optional) | Yes(Refer to the table ) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature. | |||||||||
Bypass & Protection | Input Voltage Waveform | Sine wave (Grid or Generator) | |||||||||
Nominal Voltage | 100-110-120Vac / 220-230-240Vac | ||||||||||
Max Input AC Voltage | 150VAC For 120Vac LV Mode ;300VAC For 230Vac HV Mode; | ||||||||||
Nominal Input Frequency | 50Hz or 60Hz | ||||||||||
Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | ||||||||||
High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | ||||||||||
Overload protection (SMPS load) | Circuit Breaker | ||||||||||
Output Short circuit protection | Circuit Breaker | ||||||||||
Bypass breaker rating | 10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||
Transfer switch rating | 30Amp for UL & TUV | 40Amp for UL | 80Amp for UL | ||||||||
Bypass without battery connected | Yes (Optional) | ||||||||||
Max bypass current | 30Amp | 40Amp | 80Amp | ||||||||
Mechanical Specifications | Mounting | Wall Mount | |||||||||
Inverter Dimensions(L*W *H) | 340* 420* 200mm | 425*375*200mm | 560*420*235mm | 655*490*240mm | |||||||
Inverter housing size (L*W*H) | 415* 440* 300mm | 500*495*300mm | 660*470*310mm | 720*470*290mm | |||||||
Inverter Weight(Solar Chg)KG | 16 | 19.5 | 24 | 31.5 | 33.5 | 37.5 | 56.5 | 58.5 | 61.5 | ||
Shipping Weight(Solar Chg)KG | 19 | 22 | 26.5 | 38 | 40 | 44 | 63.5 | 66 | 68.5 | ||
Display | Status LEDs / Status LEDs+LCD | ||||||||||
Standard Warranty | 2 Years (Optional) |
If the product model specification changes without notice