2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit

Brand Name:Anchorwill
Certification:3C
Model Number:Ck60
Minimum Order Quantity:1
Delivery Time:1 - 10
Payment Terms:L/C, T/T
Contact Now

Add to Cart

Verified Supplier
Location: Suzhou Jiangsu China
Address: No. 2 Anping Road, Dongbang Town, Changshu City, Suzhou, Jiangsu Province
Supplier`s last login times: within 23 hours
Product Details Company Profile
Product Details
Ball Mill Soft Starter Ck60 Built-In Bypass Soft Starter
product description

By limiting the starting current and starting torque, the soft starter is able to reliably prevent mechanical shock and grid voltage drop during starting. By controlling the conduction angle of the thyristor, the motor starting voltage is reduced and raised to the rated voltage within the set starting time. With this stepless control of the motor voltage, the motor can be regulated according to the load characteristics of the driven machine, gently accelerating the mechanical equipment.

This significantly improves the operating performance of mechanical equipment, reduces maintenance costs and extends service life.


Widely used in water supply pumps, ventilation systems, air-conditioning refrigeration station circulating pumps in water conservancy, mines, factories, high-rise buildings, large shopping malls and other places,

Fire-fighting and sprinkler pump control, etc.


ItemProject Description
Applicable standardsGB14048.6-2016(IEC947-4-2)
Applicable motor typeSquirrel-cage three-phase asynchronous motors
Motor power11A……1260A(5.5~630kW)
Control VoltageAC220V±15%;50Hz/60Hz;AC110V±15%
inputRated VoltageAC380V±15%;50Hz/60Hz;660V±15%
Adjustable start time1~120s adjustable
Adjustable stopping time0~120s adjustable
control mode1.Ramp voltage 2.Ramp current 3.Current limit mode
I/0Logic Inputs3 way(X1~X3)
Analog Outputs1 channel 4~20mA/0~10V
Relay outputs2 relay outputs
Run command inputsKeyboard display unit given, control terminal given
RS485 communication given
CommunicationIntegrated communication protocolsStandard Modbus protocol, 1 channel
Display UnitLCD displayCan display current, voltage, alarm and other motor parameters
Protection and monitoringShort-circuit, over-voltage, overload, under-voltage, phase loss, over-current, temperature protection
matrixLocationIndoor, not subject to direct sunlight, no dust, corrosive, flammable gases, oil mist,
water vapor, dripping water or salt, etc.
altitudeAltitude more than 1000m, the capacity should be reduced accordingly, every increase of 100m, the current is reduced.
Environmental humidity-10℃~+40℃; -40℃ or above shall be used at a reduced capacity.
Above 40℃ shall be used at reduced capacity
For every 1℃, the current shall be reduced by 2%.
TemperatureLess than 95%RH, no water droplet condensation.
VibrationLess than 5 .9m/s2(0 .6g)
Storage Temperature-40℃~70℃
frameworkProtection classIp20
Cooling methodRadiator, natural cooling
InstallationVertical installation in cabinet

Note:
CK60 built-in bypass economic soft starter adopts two start-stop control methods: panel giving and control terminal (two-wire and three-wire) giving.
1. Two-wire control is hold signal, three-wire control is trigger signal.
2. When two-wire control is adopted, panel control is invalid.
3. When three-wire control is used, panel control is effective.
4. When panel control is adopted, X3 and COM must be kept closed.
5. External button signal should be kept >200ms to be valid, <200ms to be invalid.


China 2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit supplier

2.2 Kw 3kw 200kw 250 Kw 400kw Soft Starter with Built-In Bypass Protection and Monitoring Short-Circuit

Inquiry Cart 0