Add to Cart
Basic Information | ||
Part Number | 02353EWU | |
Model | CR8BM8BKPAC1 | |
Description | NetEngine 8000 M8 Integrated AC Chassis Components (Including 2*AC
Power,Fan Box) | |
First supported version | V800R012C00 | |
Technical Specifications | ||
Height [mm] | 132.6 mm | |
Depth [mm] | 220 mm | |
Wide [mm] | 442 mm | |
Chassis height [U] | 3 U | |
Weight with packaging (full configuration) [kg(lb)] | [IPU-1T2/IPU-1T2-B]AC:20.6kg(45.42 lb)
[IPU-480/IPU-480-B/IPU-480-BN]AC:20.6kg(45.42 lb) | |
Weight with packaging [kg(lb)] | 11.3 kg (24.91 lb) | |
Weight without packaging (full configuration) [kg(lb)] | [IPU-1T2/IPU-1T2-B]AC:17.1kg(37.71 lb)
[IPU-480/IPU-480-B/IPU-480-BN]AC:17.1kg(37.71 lb) | |
Weight without packaging [kg(lb)] | 7.8 kg (17.2 lb) | |
Typical power consumption (with configuration) [W] | [IPU-1T2/IPU-1T2-B]AC: 2*IPU+1*fan+2*AC
power+2*CR5D0E5XMF94+1*CR5D00E4XM25+2*CR5D00LAXF91+1*CR5D00EAGF95=485.27
W [IPU-480/IPU-480-B/IPU-480-BN]AC: 2*IPU+1*fan+2*AC
power+2*CR5D0E5XMF94+2*CR5D00LAXF91+2*CR5D00EAGF95=457.79 W | |
Heat dissipation mode | Air cooling | |
Typical heat dissipation (with configuration) [BTU/hour] | [IPU-1T2/IPU-1T2-B]AC: 2*IPU+1*fan+2*AC
power+2*CR5D0E5XMF94+1*CR5D00E4XM25+2*CR5D00LAXF91+1*CR5D00EAGF95=1532.91
BTU/hour [IPU-480/IPU-480-B/IPU-480-BN]AC: 2*IPU+1*fan+2*AC
power+2*CR5D0E5XMF94+2*CR5D00LAXF91+2*CR5D00EAGF95=1443.77 BTU/hour | |
Power supply mode | AC | |
Input voltage range [V] | 90 V to 290 V | |
Rated input voltage [V] | 200V to 240V/100V to 127V dual live wires, support 240V HVDC | |
Maximum input current [A] | 10 A | |
Rated output power [W] | 1500 W | |
Number of service board slots | 6 | |
Number of slots | 11 | |
Switching capacity [bps,bit/s] | IPU-1T2/IPU-1T2-B:2.4 Tbit/s IPU-480/IPU-480-B/IPU-480-BN:960
Gbit/s | |
Redundant IPUs | 1:1 | |
Redundant fans | 1+1. Short-term running when a single fan becomes invalid at the
ambient temperature of 40°C(104°F) (one fan module contains two
fans) | |
Redundant power supply | 1+1 | |
Noise at normal temperature (acoustic power) [dB(A)] | < 72 dB (meeting the ETSI 72 dBA standard) | |
Airflow direction | From left to right | |
Maximum input cable size | Standard C13 cable | |
Front-end circuit breaker/fuse | ≥10 A | |
Restriction on the operating temperature variation rate [°C(°F)] | ≤ 0.5°C/min (32.9°F/min), non-condensing | |
Long-term operating temperature [°C(°F)] | -20°C to 55°C(-4°F to 131°F) | |
Storage temperature [°C(°F)] | –40°C to +70°C (–40°F to +158°F) | |
Long-term operating relative humidity [RH] | 5% RH to 85% RH, non-condensing | |
Storage relative humidity [RH] | 5% RH to 95% RH, non-condensing | |
Short-term operating relative humidity [RH] | 5% RH to 95% RH, non-condensing | |
Long-term operating altitude [m(ft.)] | ≤ 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to
4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of
the device decreases by 1°C [33.8°F] each time the altitude
increases by 220 m [721.78 ft.].) | |
Storage altitude [m(ft.)] | < 5000 m (16404.20 ft.) | |
MTBF [year] | 112.71 | |
MTTR [hour] | 0.5 hour | |
Availability | 0.999999494 | |
Maximum number of 25GE ports | IPU-1T2/IPU-1T2-B:24 IPU-480/IPU-480-B/IPU-480-BN:16
IPU-240/IPUA-240-B:8 | |
Maximum number of GE ports | IPU-1T2/IPU-1T2-B:120 IPU-480/IPU-480-B/IPU-480-BN:120
IPU-240/IPU-240-B:120 | |
Maximum number of electrical ports | IPU-1T2/IPU-1T2-B:60 IPU-480/IPU-480-B/IPU-480-BN:60
IPU-240/IPU-240-B:60 | |
Maximum number of 100GE ports | IPU-1T2/IPU-1T2-B:9 IPU-480/IPU-480-B/IPU-480-BN:4
IPU-240/IPU-240-B:2 | |
Maximum number of 40GE ports | IPU-1T2/IPU-1T2-B:9 IPU-480/IPU-480-B/IPU-480-BN:4
IPU-240/IPU-240-B:2 | |
Maximum number of 10GE ports | IPU-1T2/IPU-1T2-B:60 IPU-480/IPU-480-B/IPU-480-BN:48
IPU-240/IPU-240-B:24 | |
Maximum number of FE ports | IPU-1T2/IPU-1T2-B:120 IPU-480/IPU-480-B/IPU-480-BN:120
IPU-240/IPU-240-B:120 | |
Maximum number of physical ports on the entire device | 120 | |
Maximum number of 50GE ports | IPU-1T2/IPU-1T2-B:12 IPU-480/IPU-480-B/IPU-480-BN:8 | |