Product Details
What it is
The Liquiphant FTL64 is a point-level switch (limit level detector) manufactured by Endress+Hauser. It uses a
vibronic measurement principle (a vibrating fork) to detect the
presence or absence of liquid at a given point (i.e., a “limit” or
“alarm” level) in a tank, vessel or pipeline.
It is designed specifically for high‐temperature and demanding industrial applications (hot liquids, pumpable
fluids, high pressures).
How it works
- The device contains a “fork” or “tuning-fork” (vibrating element)
that is excited at a known frequency. When immersed in the liquid,
the vibration is damped; when the liquid is absent, the damping
changes. That change is detected and signals the switch. (General
vibronic principle)
- Because it’s a point detector, it gives a “liquid present / liquid
not present” signal, rather than a continuous level measurement.
- The FTL64 is offered with digital communication options,
diagnostics (Heartbeat Technology by Endress+Hauser) and supports
modern asset management and smart commissioning via e.g.,
Bluetooth/SmartBlue app.
Key Specifications & Features
Here are some of the standout technical specifications and features
(note: always check the exact model variant for your application):
- Process temperature range: from –60 °C up to +280 °C. In some versions, up to +300 °C (for
limited period) and with PFA coating up to ~230 °C.
- Process pressure range: from vacuum up to ~100 bar (depending on variant) for the normal
version; PFA coated versions have lower pressure limit (e.g., up to
~40 bar) in some cases.
- Medium density (min.): typical minimum ~0.5 g/cm³ (optionally 0.4 g/cm³) for the liquid
to be detected.
- Viscosity capability: Up to ~10,000 mm²/s (cSt) — suitable for “pumpable”
liquids/fluids.
- Materials / coatings: Choice of wetted materials (e.g., 316L stainless steel) and
optional PFA coating for aggressive media.
- Process connections: Threads, flanges, hygienic connections (Tri-Clamp) for varied
installation requirements.
- Safety & approvals: Developed per IEC 61508; rated for SIL2/3 in some variants;
certifications for explosion protection, marine approvals,
over-fill protection (e.g., WHG) included.
- Diagnostics & maintenance: Heartbeat technology enables continuous diagnostics; guided proof
testing via app or test pin/button from outside — simplifying
safety loop testing.
Where / Why You Would Use It
Typical application scenarios for the FTL64 include:
- High‐temperature liquids in industrial processes (e.g., chemical,
petrochemical, power generation) where pumps, pipelines or vessels
need level detection in hot fluid conditions.
- Over-fill protection of tanks storing hot liquids. The robust
design suits extreme temperature conditions.
- Dry‐run protection for pumps in hot liquid systems (i.e., detecting
when liquid level drops below pump suction).
- Applications where alternatives (float switches, optical sensors)
fail due to temperature, viscosity, media aggressiveness, deposits,
bubbles or other difficulties. The vibronic switch is less
sensitive to such interferences.
In short: when you need a reliable level switch under harsh conditions (high T, possibly high pressure, viscous or aggressive media) —
this product fits that niche.
Benefits / Key Advantages
- High reliability even in tough environments: high T, high P,
viscous fluids.
- Simple yet robust limit detection: less maintenance than some more
complex level measurement technologies in harsh conditions.
- Strong safety features and diagnostics built-in: ideal for critical
installations requiring SIL/over-fill protection.
- Flexibility of installation: multiple connection types, materials,
coatings make it adaptable.
- Modern commissioning/maintenance: Bluetooth/SmartBlue app,
heartbeat diagnostics simplify asset management and reduce
downtime.
Considerations / Things to Check
- Ensure the version you select supports your maximum process temperature – e.g., if you will exceed +230 °C, ensure the variant supports up
to +280 °C (or the short term +300 °C).
- Check the pressure rating for your specific application and verify the process connection’s
rating as this may define the maximum safe pressure.
- Minimum medium density must be met: if you have extremely
low‐density liquids, check whether the 0.4 g/cm³ option is needed.
- For highly aggressive media, consider the PFA-coated variant — but
note that for PFA coated version the pressure/temperature limits
may differ (lower) so review carefully.
- Even though it is robust, ensure good installation practice:
correct immersion, location free of unwanted turbulence or
splashing, correct orientation, and maintenance access for proof
testing.
- Check compatibility with your control and safety system: output
signals, diagnostics, communication (HART, Bluetooth etc) must
integrate with your system.
- Consider the lifecycle & document the proof-testing regime: for
safety critical usage (SIL, over-fill protection) you’ll want
documented testing/maintenance procedures.
Category | Description |
Product Type | Vibronic (tuning fork) point level switch for liquids |
Manufacturer | Endress+Hauser |
Measurement Principle | Vibrating fork (frequency damping changes when immersed in liquid) |
Primary Function | Reliable detection of liquid presence/absence (limit detection) |
Typical Applications | Overfill protection, dry‐run protection, level limit detection in
tanks and pipelines |
Process Temperature Range | –60 °C … +280 °C (up to +300 °C short term) |
Process Pressure Range | Vacuum … 100 bar (depending on version) |
Medium Density Range | ≥ 0.5 g/cm³ (optionally 0.4 g/cm³ for low‐density liquids) |
Viscosity Range | Up to 10,000 mm²/s (cSt) |
Wetted Materials | Stainless steel (316L / 1.4404), optional PFA coating for
aggressive media |
Process Connections | Threads, flanges, Tri-Clamp/hygienic connections |
Electrical Output / Communication | 2-wire (AC/DC), relay, transistor, PFM, or digital (HART,
Bluetooth) |
Integrated Diagnostics | Heartbeat Technology – continuous monitoring and guided proof testing |
Safety & Approvals | SIL 2/3 (IEC 61508), WHG overfill protection, Ex approvals (ATEX,
FM, CSA, etc.) |
Key Features | Robust at high T & P, maintenance-free operation, unaffected by
foam/bubbles, simple proof testing |
Installation Orientation | Horizontal or vertical (as per application) |
Maintenance | Virtually none; proof testing via Heartbeat or external test button |
Industry Sectors | Chemical, oil & gas, power generation, food & beverage,
water treatment |
Company Profile
Xi'an Xiyi Central Control Technology Co., Ltd. is an enterprise
engaged in the production, sales and R & D of industrial automation
instruments. The company is located in the ancient city of Xi'an, a
prosperous international city in China.
The company is mainly engaged in Rosemount and Yokogawa pressure
transmitters, differential pressure transmitters, liquid level
transmitters, temperature transmitters, mass flow meters and vortex
flow. Thermocouple, thermal resistance (armored, explosion-proof,
high temperature resistant, corrosion resistant, etc.), pressure
gauge, pressure gauge and bimetal thermometer. And Shanwu avp100 /
avp300 valve positioner, abb valve positioner, Siemens valve
positioner, YT valve positioner, Koso valve positioner, Shanwu
regulating valve and other products. The company has a strong
management team and brings together advanced technical talents at
home and abroad, which will provide you with better service.