What is it
- The Deltapilot FMB50 is a hydrostatic (pressure-based) level transmitter sensor, part
of the Deltapilot M line.
- It is used to measure level (or pressure) of liquids or paste‐like
media by detecting the hydrostatic pressure at a point (usually
near the bottom of a tank).
Key Features
Feature | Data / Specification |
Measuring principle | Hydrostatic / Pressure measurement. |
Measuring range | From 0.1 bar to 10 bar relative pressure, which translates to up to roughly 100 m of
water head. |
Accuracy | Standard ±0.2%, with an optional ±0.1%. |
Temperature range (process medium) | –10 °C to +100 °C (can tolerate up to +135 °C for short periods in
some versions). |
Overpressure / max process pressure | Up to 40 bar overpressure limit; process pressure rating matches
measuring cell. |
Materials (wetted parts / membrane etc.) | 316L stainless steel, Alloy C, optional coatings (e.g. AuPt).
Membrane options include gold-rhodium etc. |
Special measuring cell | “Contite” measuring cell: hermetically sealed, condensate
resistant; helps with reliable performance in humid or condensing
environments. |
Applications
- Used in both open and closed containers / tanks.
- Works with liquid and paste-like media. So even slurries or viscous fluids, as long as pressure
transmission is possible.
- Not significantly affected by foam formation (which can cause
issues for some other level sensors).
- Process and hygienic applications (e.g. food, pharma) where cleaning, material compatibility, and
possibly certifications are important.
- It is compatible with safety-instrumented systems (SIL2).
Communication / Integration
- The device can output 4-20 mA with HART protocol.
- Also available with PROFIBUS PA and FOUNDATION Fieldbus interfaces, depending on configuration.
- Local display and menu-guided commissioning (for setting up zero,
span, offsets etc.).
Advantages / What Makes It Good
- The sealed Contite cell means it handles condensate well; in cold or humid conditions, or where condensation inside
sensor housings is an issue, this helps prevent measurement errors.
- Good accuracy, stability and minimal temperature effects.
- Versatile mounting options (threads, flush hygienic, flanges etc.)
so it can be used in many tank types.
- Overpressure safety helps with process upsets. SIL2 capability
helps in safety-critical environments.
Limitations / Considerations
- Because it measures hydrostatic pressure, fluid density matters: for a given pressure reading, the height (level) depends
on density. If the density changes, you may need correction or use
of dual sensors / differential setups.
- Installation must ensure that the sensor's zero point is well
defined; avoid mounting in locations that cause turbulence,
pressure shocks, or where foaming or sludge may accumulate on the
membrane.
- For very high temperature, or extreme chemical compatibility, check
material options and coatings.
Company Profile
Xi'an Xiyi Central Control Technology Co., Ltd. is an enterprise
engaged in the production, sales and R & D of industrial automation
instruments. The company is located in the ancient city of Xi'an, a
prosperous international city in China.
The company is mainly engaged in Rosemount and Yokogawa pressure
transmitters, differential pressure transmitters, liquid level
transmitters, temperature transmitters, mass flow meters and vortex
flow. Thermocouple, thermal resistance (armored, explosion-proof,
high temperature resistant, corrosion resistant, etc.), pressure
gauge, pressure gauge and bimetal thermometer. And Shanwu avp100 /
avp300 valve positioner, abb valve positioner, Siemens valve
positioner, YT valve positioner, Koso valve positioner, Shanwu
regulating valve and other products. The company has a strong
management team and brings together advanced technical talents at
home and abroad, which will provide you with better service.