Original E+H 7f2c Series Proline Prowirl F 200 Vortex Flowmeter Flow Measurement

Brand Name:E+H
Model Number:7F2C
Minimum Order Quantity:1 pc
Delivery Time:7-14 days
Payment Terms:T/T
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: Room 2204, Unit 1, No. 91, Taoyuan South Road, Xi'an, Shaanxi, China
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

The Proline Prowirl F 200 (7F2C) is a high-precision vortex flowmeter developed by Endress+Hauser, designed for accurate measurement of wet, saturated, and superheated steam, as well as gases and liquids. It is particularly well-suited for industrial utility applications requiring reliable flow measurement and energy monitoring.

Key Features

  • Multivariable Measurement: Integrates temperature and pressure sensors, enabling direct calculation of mass flow and energy flow without the need for external devices.
  • Wet Steam Detection: Equipped with a unique wet steam detection capability, the Prowirl F 200 can identify the presence of moisture in steam, which is crucial for preventing damage to equipment and ensuring efficient energy usage.
  • Heartbeat Technology: Ensures continuous monitoring of the device's health and performance, facilitating predictive maintenance and minimizing unplanned downtime.
  • Flexible Integration: Offers seamless integration into existing infrastructures with loop-powered technology, making it cost-effective and adaptable to various industrial setups.

Specifications at a Glance

Specification

Details

Measurement Accuracy

±0.75% for liquid volume flow; ±1.00% for steam/gas volume flow

Mass Flow Accuracy

±0.85% for liquid; ±1.7% for saturated steam (temperature compensated)

Measuring Range

Liquid: 0.2 to 2100 m³/h; Steam/Gas: 1.5 to 28000 m³/h

Medium Temperature Range

Standard: –40 to +260°C; Optional: –200 to +400°C

Max. Process Pressure

PN 100, Class 600, 20K

Wetted Materials

1.4408 (CF3M), 1.4404 (316/316L), Alloy C22 (2.4602)

Process Connection Sizes

DN 25 to 300 (1 to 12 inches)

Display/Operation

4-line backlit display with touch control; remote display available

Outputs

4–20 mA HART, pulse/frequency/switch outputs

Applications

  • Steam Systems: Monitoring and optimizing steam usage in industrial processes.
  • Energy Management: Calculating energy consumption and efficiency in utilities.
  • Process Control: Ensuring accurate flow measurement for process optimization.
  • Hazardous Areas: Providing safe and reliable measurement in explosive environments.