Product Details
3144P Harsh Environment 4-20mA Output HART Protocol transmitter
Temperature Transmitter
Highlights — Features & Functions
Advanced Sensing & Accuracy
- Universal inputs: Accepts RTDs (2/3/4-wire), thermocouples (Types B, E, J, K, N, R,
S, T, L, U, W5Re/W26Re), millivolt, and ohm signals
- Single or dual‑sensor mode: Supports differential, averaging, redundant measurement,
Hot‑Backup®, and Sensor Drift Alert capabilities
- Transmitter‑Sensor Matching (C2 option): Calibrates with RTD sensor characteristics to reduce
interchangeability error by ~75%
Diagnostics & Safety
- Thermocouple loop degradation detection: Monitors for changes in resistance that might indicate wire
issues
- Min/max tracking: Continuously logs peak values for both process and ambient temps
- Sensor Drift Alert: Warns if dual-sensor readings diverge beyond preset thresholds
- Hot Backup® (U1 option): Seamlessly switches to backup sensor if primary fails, ensuring
uninterrupted output
- IEC 61508 Safety-Certified: HART‑based units certified up to SIL 2 (1oo1 logic) and SIL 3 (redundant 1oo2 setup)
- Independent fail‑safe circuit: In case of processor failure, analog output goes to preset
fail‑high or fail‑low state.
Physical & Environmental Design
- Dual‑compartment rugged housing: Offers robust protection (NEMA 4X/IP66/68) against water, dust, wiring noise, and EMI
- Enclosure materials & entries: Low‑copper aluminium or optional stainless steel, with ½‑14 NPT,
M20, PG13.5, or JIS conduit options
- Operating & storage range: –40 °C to +85 °C (electronics); –60 °C to +120 °C (storage) .
- Stability specs: RTDs maintain ±0.25 % or ±0.25 °C over 5 years; thermocouples ±0.5 % or ±0.5 °C
- Self‑calibrating ADC and robust EMC performance (IEC 61000‑4‑3 up to 30 V/m test)
Communication & Local Interface
- 4‑20 mA + HART (Rev 5/7) or FOUNDATION Fieldbus (ITK 6.0, NE107) with built‑in AI, PID, and advanced diagnostics function blocks
- Local LCD display: Shows process value and diagnostics graphically; suave
configuration and verification onsite
Wiring / Configuration Snapshots
- Single sensor wiring: Standard RTD or thermocouple hook-up diagrams available for HART
and Fieldbus modes.
- Dual sensor wiring: Supports dual RTDs, dual T/Cs, or mixed RTD+T/C setups—ideal for
ΔT, averaging, or redundant measurements
- Typical response time: ~0.5 s for single-sensor mode, ~1 s for dual sensors.
Available Options & Configurability
Option Code | Feature |
PT | X‑well™ pipe clamp sensor assembly |
C1 | Factory data: date, tag, custom alarms |
C2 | Transmitter‑sensor matching |
Q4 | 5‑point calibration certificate |
U1/U2 | Hot Backup, averaging, drift alert modes |
M5 | Local LCD display |
T1 | Transient protection |
QT | SIL certification |
HR7 | HART revision 7 |
Company Profile
Xi'an Xiyi Central Control Technology Co., Ltd. is an enterprise
engaged in the production, sales and R & D of industrial automation
instruments. The company is located in the ancient city of Xi'an, a
prosperous international city in China.
The company is mainly engaged in Rosemount and Yokogawa pressure
transmitters, differential pressure transmitters, liquid level
transmitters, temperature transmitters, mass flow meters and vortex
flow. Thermocouple, thermal resistance (armored, explosion-proof,
high temperature resistant, corrosion resistant, etc.), pressure
gauge, pressure gauge and bimetal thermometer. And Shanwu avp100 /
avp300 valve positioner, abb valve positioner, Siemens valve
positioner, YT valve positioner, Koso valve positioner, Shanwu
regulating valve and other products. The company has a strong
management team and brings together advanced technical talents at
home and abroad, which will provide you with better service.