Streamline Power Supply Problem Detection With 475 Handheld Communicator

Brand Name:Rosemount
Model Number:475
Minimum Order Quantity:1 pc
Delivery Time:7-14 days
Payment Terms:T/T
Place of Origin:China
Contact Now

Add to Cart

Verified Supplier
Address: Room 2204, Unit 1, No. 91, Taoyuan South Road, Xi'an, Shaanxi, China
Supplier`s last login times: within 27 hours
Product Details Company Profile
Product Details

The Emerson Process Management 475 Field Communicator


The Emerson Process Management 475 Field Communicator is a versatile and powerful tool designed to simplify and enhance field operations in industrial settings. Its advanced features and compatibility with various protocols make it suitable for a wide range of applications. Here are some common uses for the 475 HART Field Communicator:

1. **Device Configuration and Setup**:
- Configure and set up HART, FOUNDATION fieldbus, and Wireless HART devices.
- Adjust device parameters, such as range, units, and damping, to optimize performance.

2. **Diagnostics and Troubleshooting**:
- Perform advanced diagnostics to identify and resolve issues with field devices.
- Access detailed device health and status information to ensure optimal operation.

3. **Calibration and Maintenance**:
- Calibrate field devices to maintain accuracy and reliability.
- Perform routine maintenance tasks, such as trimming and zero adjustments.

4. **Monitoring and Data Collection**:
- Monitor real-time process variables, such as pressure, temperature, and flow.
- Collect and log data from field devices for analysis and reporting.

5. **Device Commissioning**:
- Commission new devices quickly and efficiently, reducing downtime during installation.
- Verify device functionality and ensure proper integration with the control system.

6. **Firmware Updates**:
- Upgrade device firmware onsite using the Internet to ensure devices are running the latest software versions.
- Enhance device performance and add new features through firmware updates.

7. **Asset Management**:
- Manage and track field devices using asset management tools.
- Maintain an inventory of devices and their configurations for better organization and planning.

8. **Wireless Device Management**:
- Configure and manage Wireless HART devices, enabling seamless integration into wireless networks.
- Monitor and troubleshoot wireless devices to ensure reliable communication and performance.

9. **Documentation and Reporting**:
- Generate detailed reports on device configuration, diagnostics, and maintenance activities.
- Document changes and updates for compliance and audit purposes.

10. **Training and Support**:
- Use the 475 Field Communicator as a training tool for field technicians and engineers.
- Provide on-site support and training to ensure proper use and maintenance of field devices.

The Emerson 475 Field Communicator's intuitive interface, robust diagnostic capabilities, and compatibility with multiple protocols make it an indispensable tool for field technicians and engineers, helping to streamline operations, reduce downtime, and improve overall efficiency.


475 Field Communicator Specifications
Memory internal flash32 MB
System card1 GB secure digital card
RAM32 MB
WeightApp. 1.65 lb (0.75 kg) w/battery
Display1/4 VGA (240 x 320 px) color, 3.5 in (8,9 cm) transreflective display w/touchscreen, anti-glare coat
Keypad25 keys including 4 action keys, 12 alphanumeric keys, tab key, function key, backlight key, power key, and 4 cursor-control (arrow) keys; membrane design with tactile feedback
BatteryRechargeable lithium-ion power module
Battery operating time20 hours - continuous use
40 hours - typical use
80 hours - standby mode
Battery charger optionsInput voltage 100-240 VAC, 50-60 Hz
Cables included with US, Europe, and UK plugs
Battery chargerMin DIN 6-pin jack
HART and FieldbusThree 4mm banana plugs (one common to HART and Foundation fieldbus)
IrDA PortIrDA (Infrared Data Access) port supporting up to 115 Kbps
±15 degrees recommended maximum angle from center line
App. 18 in recommended maximum distance
BluetoothUp to 32.8 ft (10 m) communication distance
Uses standard Windows drivers
FCC, IC and CE approvals

FAQ


Q: How long will you give me the reply?

A: We will contact you within 2 working days.

Q: What is the delivery time?

A: Our delivery time is within 3-7 working days after we get the payment; for large qty mass order the time should be confirmed again for you.

Q: How about your package?

A: Do not worry about the package, we have rich experience at packing, all our package is standard exporting package.

Q: How about the payment terms?

A: You can choose T/T, Western union, or you can choose by - credit insurance.

Q: Could I visit your factory?

A: Sincerely Invite you to visit our factory

Q: Do you provide samples?

A: Yes, we have material is in stock to help you to get the samples as soon as we can.

Q: What Is the MOQ?

A: 1PC.

Q: Can I get a lower price if I order large quantities?

A: Yes, cheaper prices with more bigger size orders.

China Streamline Power Supply Problem Detection With 475 Handheld Communicator supplier

Streamline Power Supply Problem Detection With 475 Handheld Communicator

Inquiry Cart 0