HD8000 series VFD is a high-power drive system includes AC-DC-AC comverter and DC-AC common DC bus multi-axis motor drive unit. The maximum power can reach 30MVA for single machine and 60MVA for parallel operation. Its modular hardware and engineering software design concept enables it to operate for various complex conditions.
HD8000 series VFD adopts presspack IGCTand Diode as well as liquid cooling method, the whole machine meets the protection level IP54 and it has super environmental adaptability, high reliability, excellent heat dissipation performance and small volume, there are two-quadrant and four-quadrant rectification solutions.
| HD8000 Technical Specifications | ||||||||||||||
| HD8000 | 3306 | 3308 | 3310 | 3312 | 2624 | AA30 | 6640 | AA60 | ||||||
| R Basical ectification | Input voltage | 3300V | 1900V | 10kV | 6600V | 10kV | ||||||||
| Input frquency | 45Hz-66Hz | |||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥99% | |||||||||||||
| Power factor | ≥0.95 (Rated current, equipped with 2% AC input reactor) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| RecPWM tification | Input frquency | 45Hz-66Hz | ||||||||||||
| Overload | 110%@ rated current, 120%@ rated current 60s | |||||||||||||
| Efficiency | ≥98.5% | |||||||||||||
| Power factor | adjustable (default 1) | |||||||||||||
| Protection | overload protection, overheat protection, short circuit protection, fault pre-judgment, etc | |||||||||||||
| Inverter | Output voltage | 3300V | 6600V | 10kV | 6600V | 10kV | ||||||||
| Max output frequency | 110Hz | |||||||||||||
| Speed stable accuracy | OLVC: 0.01%, CLVC: 0.01% | OLVC: 0.01%, CLVC: 0.01% | ||||||||||||
| Speed pulse | OLVC: 0.2%, CLVC: 0.1% | OLVC: 0.4%, CLVC: 0.2% | ||||||||||||
| Start torque | OLVC: 150%, CLVC: 200% | OLVC: 130%, CLVC: 150% | ||||||||||||
| Torque control | V/F: Yes, OLVC: Yes, CLVC: Yes | V/F: Yes, OLVC: Yes, CLVC: Yes | ||||||||||||
| Torque accuracy | OLVC: 5%, CLVC: 2% | OLVC: 5%, CLVC: 2% | ||||||||||||
| Torque response time | OLVC: 5ms, CLVC: 5ms | OLVC: 5ms, CLVC: 5ms | ||||||||||||
| Rotating response time | OLVC: 100ms, CLVC: 100ms | OLVC: 150ms, CLVC: 150ms | ||||||||||||
| Dynamic drop equivalent | OLVC: 0.5%*s, CLVC: 0.25%*s | OLVC: 1%*s, CLVC: 0.5%*s | ||||||||||||
| Overload | 110%@rated current, 120%@rated current 60s | |||||||||||||
| Environment | Temperature | inlet temperature ≤40 | ||||||||||||
| Altitude | ≤4000m (2000m~4000m de-rating) | |||||||||||||
| Mechanical Data | IP protection | IP54 | ||||||||||||
| Cooling | Water cooling | |||||||||||||
| Anti corrosion | C4-M | |||||||||||||
| Module | Grid Voltage | Motor Voltage | Power | RatedI | Max f | Size (W*D*H) (mm) | Note | |||||||
| HD8000-3306 | 3300V | 3300V | 6MVA | 1050A | 110Hz | 4600*1300*2200 | Contains water cool cabinet | |||||||
| HD8000-3308 | 8MVA | 1400A | ||||||||||||
| HD8000-3310 | 10MVA | 1750A | ||||||||||||
| HD8000-3312 | 12MVA | 2100A | ||||||||||||
| HD8000-2624 | 1900V | 6600V | 24MVA | 2100A | 7800*1300*2200 | |||||||||
| HD8000-AA30 | 10kV | 10kV | 30MVA | 1750A | 10600*1300*2200 | |||||||||
| HD8000-6640 | 6600V | 6600V | 40MVA | 3500A | 15600*1300*2200 | |||||||||
| HD8000-AA60 | 10kV | 10kV | 60MVA | 3500A | 21200*1600*2200 | |||||||||