Fit & Install Instructions:
- Initial Check:Ensure the sensor is undamaged.Verify that the wiring
is complete.
- Installation and Connection:Align the airflow direction with the
sensor's airflow indication direction.Connect the sensor lead line
correctly based on the wiring definition.
- Power Connection:Confirm the correct connection before
proceeding.Connect the power supply to initiate operation.
- Preheating for Accuracy:For optimal accuracy, preheat the sensor
for 2 minutes by connecting it to the power supply.
Performance Metrics:
- Test Conditions:Voltage Input (Vin): 12 ± 0.1 VDC.Ambient
Temperature (Ta): 25°CRelative Humidity: 40% < relative humidity
< 60%
- Maximum Operating Temperature Range: -15°C to +70°C
Specifications:
Parameter | Least Value | Normal Value | Crest Value | Unit | Remarks |
---|
Flow Range | 0 | 10000 | | sccm | Customizable |
Service Voltage | | 8-24V | | V | Customizable |
Current | | 50 | | mA | |
Maximum Voltage Output | 4.96 | 5 | 5.02 | V | Linear |
Zero Point Voltage Output | 0.98 | 1 | 1.02 | V | Linear |
Accuracy | 1.5 | 2 | | %FS | |
Repetitiveness | ±0.3 | | | % | |
Resolution Ratio | | 0.1 | | % gamut | |
Withstand Voltage | 0.3 | 0.5 | | MPa | Customizable |
Response Time | 9 | 65 | 500 | ms | Customizable |
Zero Drift | | 0.2 | | %Year | gamut |
Calibration Conditions | | 0℃, 1 standard atmosphere | | | |
Overall Material | | Silicon carbide, epoxy resin, PPS, and silicon | | Sealing materials | |
Maximum Ratings:
- Operating Temperature: -15°C to 70°C
- Storage Temperature: -25°C to 85°C
- Humidity: 0% to 100% RH
- Weight: 100 g
- Resistance: The sensor is resistant to condensate water.